A. Zarubin, D. Mokeev, V. Novikov, O. Tolbanov, A. Tyazhev
{"title":"砷化镓:铬x射线像素探测器","authors":"A. Zarubin, D. Mokeev, V. Novikov, O. Tolbanov, A. Tyazhev","doi":"10.1109/SIBCON.2011.6072649","DOIUrl":null,"url":null,"abstract":"Results of investigation of quantum count mode gallium arsenide pixel detectors are demonstrated. It was shown that at room temperature energy resolution of GaAs detector similar to silicon ones. But detection quantum efficiency (DQE) of 30 keV gamma-quanta of GaAs detector exceeds DQE of Si detector more then order of magnitude.","PeriodicalId":169606,"journal":{"name":"2011 International Siberian Conference on Control and Communications (SIBCON)","volume":"42 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-11-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"GaAs:Cr X-ray pixel detectors\",\"authors\":\"A. Zarubin, D. Mokeev, V. Novikov, O. Tolbanov, A. Tyazhev\",\"doi\":\"10.1109/SIBCON.2011.6072649\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Results of investigation of quantum count mode gallium arsenide pixel detectors are demonstrated. It was shown that at room temperature energy resolution of GaAs detector similar to silicon ones. But detection quantum efficiency (DQE) of 30 keV gamma-quanta of GaAs detector exceeds DQE of Si detector more then order of magnitude.\",\"PeriodicalId\":169606,\"journal\":{\"name\":\"2011 International Siberian Conference on Control and Communications (SIBCON)\",\"volume\":\"42 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-11-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 International Siberian Conference on Control and Communications (SIBCON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SIBCON.2011.6072649\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 International Siberian Conference on Control and Communications (SIBCON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SIBCON.2011.6072649","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Results of investigation of quantum count mode gallium arsenide pixel detectors are demonstrated. It was shown that at room temperature energy resolution of GaAs detector similar to silicon ones. But detection quantum efficiency (DQE) of 30 keV gamma-quanta of GaAs detector exceeds DQE of Si detector more then order of magnitude.