扩展测量腔的相传递函数对中频的贡献和总体误差预算

G. Fütterer, J. Liebl, A. Haberl
{"title":"扩展测量腔的相传递函数对中频的贡献和总体误差预算","authors":"G. Fütterer, J. Liebl, A. Haberl","doi":"10.1117/12.2318711","DOIUrl":null,"url":null,"abstract":"A challenge of coaxial - measurement cavity based - interferometer is to realize an interference contrast in the vicinity of one and to realize a complete elimination of the parasitic reflections. Another challenge, which also exists in non-coaxial setups, is the phase transfer function of extended measurement cavities. Ideally, the surface under test (SUT) and the reference surface (REF) are both exactly imaged onto the detector plane. In practice, SUT and REF have to be placed within the depth of field (DOF), which refers to the object space. The term depth of focus refers to the image space. To avoid confusion, the depth of field might be referred to as DOOF (depth of object field) and the depth of focus might be referred to as DOIF (depth of image field). However, in many measurement situations, the REF is not placed within the DOOF, which is the small z-range, which is imaged onto the detector plane. Furthermore, the phase transfer function (PTF) of the REF and the image distortion of the REF are both dependent on the focal plane used to image the SUT onto the detector plane. Effects as phase deformation, image distortion and image blurring have to be taken into account when using extended measurement cavities. This can be done by using a look up table (LUT), which contains simulated and/or calibrated data. Thus, the related system error can be subtracted. A remaining challenge is an unknown object under test (OUT), which is measured by using a double path arrangement. The measured wave front depends on the two surfaces of the OUT and the position of the return mirror. For simplicity, a homogeneous substrate and a perfect return mirror might be presumed. The simulation of waves propagating within extended measurement cavities, as well as measurement results, will be discussed. In addition, the influence on the power spectral density (PSD) will be described. This is important for high end correction techniques as e.g. magneto rheological figuring (MRF) and ion beam figuring (IBF).","PeriodicalId":422212,"journal":{"name":"Precision Optics Manufacturing","volume":"29 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-08-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Contribution of the phase transfer function of extended measurement cavities to mid spatial frequencies and the overall error budget\",\"authors\":\"G. Fütterer, J. Liebl, A. Haberl\",\"doi\":\"10.1117/12.2318711\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A challenge of coaxial - measurement cavity based - interferometer is to realize an interference contrast in the vicinity of one and to realize a complete elimination of the parasitic reflections. Another challenge, which also exists in non-coaxial setups, is the phase transfer function of extended measurement cavities. Ideally, the surface under test (SUT) and the reference surface (REF) are both exactly imaged onto the detector plane. In practice, SUT and REF have to be placed within the depth of field (DOF), which refers to the object space. The term depth of focus refers to the image space. To avoid confusion, the depth of field might be referred to as DOOF (depth of object field) and the depth of focus might be referred to as DOIF (depth of image field). However, in many measurement situations, the REF is not placed within the DOOF, which is the small z-range, which is imaged onto the detector plane. Furthermore, the phase transfer function (PTF) of the REF and the image distortion of the REF are both dependent on the focal plane used to image the SUT onto the detector plane. Effects as phase deformation, image distortion and image blurring have to be taken into account when using extended measurement cavities. This can be done by using a look up table (LUT), which contains simulated and/or calibrated data. Thus, the related system error can be subtracted. A remaining challenge is an unknown object under test (OUT), which is measured by using a double path arrangement. The measured wave front depends on the two surfaces of the OUT and the position of the return mirror. For simplicity, a homogeneous substrate and a perfect return mirror might be presumed. The simulation of waves propagating within extended measurement cavities, as well as measurement results, will be discussed. In addition, the influence on the power spectral density (PSD) will be described. This is important for high end correction techniques as e.g. magneto rheological figuring (MRF) and ion beam figuring (IBF).\",\"PeriodicalId\":422212,\"journal\":{\"name\":\"Precision Optics Manufacturing\",\"volume\":\"29 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-08-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Precision Optics Manufacturing\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1117/12.2318711\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Precision Optics Manufacturing","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2318711","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

同轴测量腔型干涉仪面临的挑战是如何实现1附近的干涉对比度,并完全消除寄生反射。另一个挑战,也存在于非同轴设置中,是扩展测量腔的相传递函数。理想情况下,被测表面(SUT)和参考表面(REF)都精确成像到探测器平面上。在实践中,SUT和REF必须放置在景深(DOF)内,这是指对象空间。聚焦深度一词指的是图像空间。为避免混淆,景深可称为DOOF(对象景深),焦距可称为DOIF(图像景深)。然而,在许多测量情况下,REF没有被放置在DOOF内,这是一个很小的z范围,它被成像到探测器平面上。此外,reft的相传递函数(PTF)和reft的像畸变都依赖于SUT成像到探测器平面的焦平面。在使用扩展测量腔时,必须考虑相位变形、图像失真和图像模糊等影响。这可以通过使用包含模拟和/或校准数据的查找表(LUT)来完成。这样就可以减去相关的系统误差。剩下的挑战是一个未知的被测对象(OUT),它是通过使用双路径安排来测量的。测得的波前取决于外镜的两个表面和反射镜的位置。为简单起见,可以假设有一个均匀的衬底和一个完美的回镜。将讨论波在扩展测量腔内传播的模拟,以及测量结果。此外,还将描述对功率谱密度(PSD)的影响。这对于高端校正技术非常重要,例如磁流变校正(MRF)和离子束校正(IBF)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Contribution of the phase transfer function of extended measurement cavities to mid spatial frequencies and the overall error budget
A challenge of coaxial - measurement cavity based - interferometer is to realize an interference contrast in the vicinity of one and to realize a complete elimination of the parasitic reflections. Another challenge, which also exists in non-coaxial setups, is the phase transfer function of extended measurement cavities. Ideally, the surface under test (SUT) and the reference surface (REF) are both exactly imaged onto the detector plane. In practice, SUT and REF have to be placed within the depth of field (DOF), which refers to the object space. The term depth of focus refers to the image space. To avoid confusion, the depth of field might be referred to as DOOF (depth of object field) and the depth of focus might be referred to as DOIF (depth of image field). However, in many measurement situations, the REF is not placed within the DOOF, which is the small z-range, which is imaged onto the detector plane. Furthermore, the phase transfer function (PTF) of the REF and the image distortion of the REF are both dependent on the focal plane used to image the SUT onto the detector plane. Effects as phase deformation, image distortion and image blurring have to be taken into account when using extended measurement cavities. This can be done by using a look up table (LUT), which contains simulated and/or calibrated data. Thus, the related system error can be subtracted. A remaining challenge is an unknown object under test (OUT), which is measured by using a double path arrangement. The measured wave front depends on the two surfaces of the OUT and the position of the return mirror. For simplicity, a homogeneous substrate and a perfect return mirror might be presumed. The simulation of waves propagating within extended measurement cavities, as well as measurement results, will be discussed. In addition, the influence on the power spectral density (PSD) will be described. This is important for high end correction techniques as e.g. magneto rheological figuring (MRF) and ion beam figuring (IBF).
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Fast, semi-automated geometric and functional characterization of miniaturized lenses using optical coherence tomography-based systems and wavefront sensors Simulation of system transmission values for different angles of incidence Acoustic emissions in the glass polishing process: a possible approach for process monitoring Conceptual considerations for the paperless production of ophthalmic lenses Superposition of cryogenic and ultrasonic assisted machining of Zerodur
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1