{"title":"数字变电站信号采集系统中异常数据的处理","authors":"Chi Zhang, X. Kang, Z. Jiao, Jianfei Ji","doi":"10.1109/APPEEC.2016.7779843","DOIUrl":null,"url":null,"abstract":"Abnormal data would appear in the signal acquisition system of a digital substation as a result of the disturbance from external environment. A data processing algorithm is proposed in this paper in order to meet the challenge of the abnormal data. It is proved in this paper that any three consecutive sampling values should satisfy a certain constraint condition in the ideal situation of the power system. The constraint condition is used to judge whether a real sampling value is abnormal. A complete algorithm is presented including three main steps. Simulation work verifies the effectiveness of the algorithm.","PeriodicalId":117485,"journal":{"name":"2016 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Countermeasures on abnormal data in the signal acquisition system of digital substations\",\"authors\":\"Chi Zhang, X. Kang, Z. Jiao, Jianfei Ji\",\"doi\":\"10.1109/APPEEC.2016.7779843\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abnormal data would appear in the signal acquisition system of a digital substation as a result of the disturbance from external environment. A data processing algorithm is proposed in this paper in order to meet the challenge of the abnormal data. It is proved in this paper that any three consecutive sampling values should satisfy a certain constraint condition in the ideal situation of the power system. The constraint condition is used to judge whether a real sampling value is abnormal. A complete algorithm is presented including three main steps. Simulation work verifies the effectiveness of the algorithm.\",\"PeriodicalId\":117485,\"journal\":{\"name\":\"2016 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)\",\"volume\":\"17 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APPEEC.2016.7779843\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APPEEC.2016.7779843","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Countermeasures on abnormal data in the signal acquisition system of digital substations
Abnormal data would appear in the signal acquisition system of a digital substation as a result of the disturbance from external environment. A data processing algorithm is proposed in this paper in order to meet the challenge of the abnormal data. It is proved in this paper that any three consecutive sampling values should satisfy a certain constraint condition in the ideal situation of the power system. The constraint condition is used to judge whether a real sampling value is abnormal. A complete algorithm is presented including three main steps. Simulation work verifies the effectiveness of the algorithm.