{"title":"油渍牛皮纸耐久性系数的DEM估算","authors":"G. N. Reddy, Birender Singh, Iyyappan, A. Tiwana, C. Reddy","doi":"10.1109/CATCON47128.2019.CN0008","DOIUrl":null,"url":null,"abstract":"Kraft paper is one of the most commonly used insulation in transformers and cables. Impregnation with transformer grade mineral oil is done to improve the electrical properties of the paper. Voltage endurance coefficient (n) is used to estimate the performance characteristics of the insulation paper aging. In this paper, a comparative study is done to estimate the endurance coefficient using conventional V-t curve method and Damage Equalization Method (DEM). The endurance coefficient is also known as the power law coefficient which is used in the V-t curve method to characterize the insulation aging. The unknown power law coefficient is also obtained from known values of step durations and stresses for each sample till its breakdown under DEM. Various types of AC Breakdown tests were performed on cable insulation of different ages obtained from a local manufacturer.","PeriodicalId":183797,"journal":{"name":"2019 IEEE 4th International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)","volume":"36 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Estimation of Endurance Coefficient of Oil Impregnated Kraft Papers using DEM\",\"authors\":\"G. N. Reddy, Birender Singh, Iyyappan, A. Tiwana, C. Reddy\",\"doi\":\"10.1109/CATCON47128.2019.CN0008\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Kraft paper is one of the most commonly used insulation in transformers and cables. Impregnation with transformer grade mineral oil is done to improve the electrical properties of the paper. Voltage endurance coefficient (n) is used to estimate the performance characteristics of the insulation paper aging. In this paper, a comparative study is done to estimate the endurance coefficient using conventional V-t curve method and Damage Equalization Method (DEM). The endurance coefficient is also known as the power law coefficient which is used in the V-t curve method to characterize the insulation aging. The unknown power law coefficient is also obtained from known values of step durations and stresses for each sample till its breakdown under DEM. Various types of AC Breakdown tests were performed on cable insulation of different ages obtained from a local manufacturer.\",\"PeriodicalId\":183797,\"journal\":{\"name\":\"2019 IEEE 4th International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)\",\"volume\":\"36 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 IEEE 4th International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CATCON47128.2019.CN0008\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE 4th International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CATCON47128.2019.CN0008","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

牛皮纸是变压器和电缆中最常用的绝缘材料之一。用变压器级矿物油浸渍,提高了纸的电性能。用耐压系数(n)来估计绝缘纸老化的性能特征。本文对传统的V-t曲线法和损伤均等化法(DEM)估算耐久性系数进行了对比研究。耐久系数又称幂律系数,在V-t曲线法中用于表征绝缘老化。未知的幂律系数也由已知的阶跃持续时间和应力值得到,直到每个样本在DEM下被击穿。对从当地厂家获得的不同年限的电缆绝缘进行了各种类型的交流击穿试验。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Estimation of Endurance Coefficient of Oil Impregnated Kraft Papers using DEM
Kraft paper is one of the most commonly used insulation in transformers and cables. Impregnation with transformer grade mineral oil is done to improve the electrical properties of the paper. Voltage endurance coefficient (n) is used to estimate the performance characteristics of the insulation paper aging. In this paper, a comparative study is done to estimate the endurance coefficient using conventional V-t curve method and Damage Equalization Method (DEM). The endurance coefficient is also known as the power law coefficient which is used in the V-t curve method to characterize the insulation aging. The unknown power law coefficient is also obtained from known values of step durations and stresses for each sample till its breakdown under DEM. Various types of AC Breakdown tests were performed on cable insulation of different ages obtained from a local manufacturer.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Eddy Current and Magneto-Structural Analysis on Transformer Winding with Continuously Transposed Conductors Estimation of Endurance Coefficient of Oil Impregnated Kraft Papers using DEM Effect of filler concentration on breakdown of Isotactic Polypropylene Nano-composites A Novel Autonomous Technique for Early Fault Detection on Overhead Power Lines CATCON 2019 Cover Page
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1