D- -Σ数字控制降压变换器的设计与实现

Tsai-Fu Wu, Tin Chang, Chih Chang, L. Lin
{"title":"D- -Σ数字控制降压变换器的设计与实现","authors":"Tsai-Fu Wu, Tin Chang, Chih Chang, L. Lin","doi":"10.1109/INTLEC.2015.7572266","DOIUrl":null,"url":null,"abstract":"This paper presents design and implementation of a dc/dc converter with division-summation (D-Σ) digital control. With the control, the converter is allowed to have wide inductance variation caused by high current flowing through inductor, and to track current reference precisely for achieving tight output voltage regulation. Moreover, the control can reduce steady-state error as compared with peak current-mode control and achieve faster dynamic response over average current-mode control. This paper also presents a precise current reference calculation to avoid sub-harmonic oscillation of inductor current under discontinuous conduction mode. Experimental results have verified the analysis and discussion.","PeriodicalId":211948,"journal":{"name":"2015 IEEE International Telecommunications Energy Conference (INTELEC)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2015-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Design and implementation of step-down converter with D-Σ digital control\",\"authors\":\"Tsai-Fu Wu, Tin Chang, Chih Chang, L. Lin\",\"doi\":\"10.1109/INTLEC.2015.7572266\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents design and implementation of a dc/dc converter with division-summation (D-Σ) digital control. With the control, the converter is allowed to have wide inductance variation caused by high current flowing through inductor, and to track current reference precisely for achieving tight output voltage regulation. Moreover, the control can reduce steady-state error as compared with peak current-mode control and achieve faster dynamic response over average current-mode control. This paper also presents a precise current reference calculation to avoid sub-harmonic oscillation of inductor current under discontinuous conduction mode. Experimental results have verified the analysis and discussion.\",\"PeriodicalId\":211948,\"journal\":{\"name\":\"2015 IEEE International Telecommunications Energy Conference (INTELEC)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE International Telecommunications Energy Conference (INTELEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/INTLEC.2015.7572266\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE International Telecommunications Energy Conference (INTELEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/INTLEC.2015.7572266","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文介绍了一种带有除法求和(D-Σ)数字控制的dc/dc变换器的设计与实现。通过这种控制,可以使变换器在大电流流过电感时产生较大的电感变化,并精确跟踪电流基准,从而实现严密的输出电压调节。与峰值电流模式控制相比,该控制可以减小稳态误差,实现比平均电流模式控制更快的动态响应。本文还提出了一种精确的电流参考计算方法,以避免电感电流在断续导通模式下的次谐波振荡。实验结果验证了分析和讨论的正确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Design and implementation of step-down converter with D-Σ digital control
This paper presents design and implementation of a dc/dc converter with division-summation (D-Σ) digital control. With the control, the converter is allowed to have wide inductance variation caused by high current flowing through inductor, and to track current reference precisely for achieving tight output voltage regulation. Moreover, the control can reduce steady-state error as compared with peak current-mode control and achieve faster dynamic response over average current-mode control. This paper also presents a precise current reference calculation to avoid sub-harmonic oscillation of inductor current under discontinuous conduction mode. Experimental results have verified the analysis and discussion.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
An Energy Optimization Model (EOM) to reduce mobile service providers network costs: A multi-objective optimization approach Peak-cut control of smart energy BTS: Power control technology for reducing the power consumed by base stations Performance characteristic of interleaved LLC resonant converter with phase shift modulation Research and application of green power system for new data centers The cost benefits of deploying line powering systems from a centralized location over an existing a copper twisted-pair outside plant to energize remote equipment in the distributed telecom network
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1