{"title":"三电平逆变交流驱动的PWM策略","authors":"S. Halász, A. Zakharov","doi":"10.1109/IAS.2002.1043804","DOIUrl":null,"url":null,"abstract":"In the region of high voltage and power, a high quality inverter-fed AC drive is more easily obtained by the use of multi-level inverters. In the first case three-level inverters should be taken into consideration. One of the important quality indexes of the PWM technique is the inverter-fed motor harmonic losses. They can be characterized by the generalized loss-factor. It is shown that for three-level inverters three different PWM regions can be introduced where different PWM strategies should be applied. The paper deals with computations of the generalized loss-factor of three-level inverters in the case of space vector modulation and the comparison of the different PWM methods on the basis of this factor. It is shown that the generalized loss-factors of three-level inverters are 4-35 times lower than those are for two-level inverters.","PeriodicalId":202482,"journal":{"name":"Conference Record of the 2002 IEEE Industry Applications Conference. 37th IAS Annual Meeting (Cat. No.02CH37344)","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-12-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":"{\"title\":\"PWM strategies of three-level inverter-fed AC drives\",\"authors\":\"S. Halász, A. Zakharov\",\"doi\":\"10.1109/IAS.2002.1043804\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In the region of high voltage and power, a high quality inverter-fed AC drive is more easily obtained by the use of multi-level inverters. In the first case three-level inverters should be taken into consideration. One of the important quality indexes of the PWM technique is the inverter-fed motor harmonic losses. They can be characterized by the generalized loss-factor. It is shown that for three-level inverters three different PWM regions can be introduced where different PWM strategies should be applied. The paper deals with computations of the generalized loss-factor of three-level inverters in the case of space vector modulation and the comparison of the different PWM methods on the basis of this factor. It is shown that the generalized loss-factors of three-level inverters are 4-35 times lower than those are for two-level inverters.\",\"PeriodicalId\":202482,\"journal\":{\"name\":\"Conference Record of the 2002 IEEE Industry Applications Conference. 37th IAS Annual Meeting (Cat. No.02CH37344)\",\"volume\":\"3 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-12-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"11\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference Record of the 2002 IEEE Industry Applications Conference. 37th IAS Annual Meeting (Cat. No.02CH37344)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IAS.2002.1043804\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of the 2002 IEEE Industry Applications Conference. 37th IAS Annual Meeting (Cat. No.02CH37344)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IAS.2002.1043804","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

摘要

在高压大功率领域,采用多级逆变器更容易获得高质量的逆变供电交流驱动。在第一种情况下,应考虑三电平逆变器。PWM技术的一个重要质量指标是逆变器供电电机的谐波损耗。它们可以用广义损失因子来表征。结果表明,对于三电平逆变器,可以引入三个不同的PWM区域,其中应采用不同的PWM策略。本文讨论了空间矢量调制情况下三电平逆变器广义损耗因子的计算,并在此基础上对不同PWM方法进行了比较。结果表明,三电平逆变器的广义损耗因子比二电平逆变器的广义损耗因子低4 ~ 35倍。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
PWM strategies of three-level inverter-fed AC drives
In the region of high voltage and power, a high quality inverter-fed AC drive is more easily obtained by the use of multi-level inverters. In the first case three-level inverters should be taken into consideration. One of the important quality indexes of the PWM technique is the inverter-fed motor harmonic losses. They can be characterized by the generalized loss-factor. It is shown that for three-level inverters three different PWM regions can be introduced where different PWM strategies should be applied. The paper deals with computations of the generalized loss-factor of three-level inverters in the case of space vector modulation and the comparison of the different PWM methods on the basis of this factor. It is shown that the generalized loss-factors of three-level inverters are 4-35 times lower than those are for two-level inverters.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Resonant filter applications in electronic ballast Novel method in decreasing grounding resistances of urban substations by utilizing peripheral geographical conditions Practical design considerations of a single-stage single-switch parallel PFC converter for universal voltage applications Drug delivery studies on electrostatically charged dry powder inhaler aerosols using a glass bead lung model A simple rolling mill model with linear quadratic optimal controller
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1