{"title":"光伏系统退化风险评估方法","authors":"A. C. Ciocea F. Munteanu C. Nemes, F. Munteanu, C. Nemeş","doi":"10.1109/ICEPE.2018.8559803","DOIUrl":null,"url":null,"abstract":"The paper presents the failure modes, the effects and the criticality for each element in the architecture and operation of a photovoltaic system. A typical configuration is considered: photovoltaic panel, junction box, connection cables, controller, battery and inverter. The first part of this study generally describes the current state of the failure modes and effects for each element of the photovoltaic system. In the second part of the study is presented a structured case study based on the LACARP photovoltaic system that is part of LACARP’s laboratory of Faculty of Electrical Engineering of the “Gheorghe Asachi” Technical University of Iasi including customized criteria and indicators for each element of a photovoltaic system. This approach will help establishing the hierarchy and the integration of each failure mode and the level of rated power affected.","PeriodicalId":343896,"journal":{"name":"2018 International Conference and Exposition on Electrical And Power Engineering (EPE)","volume":"41 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Method to Assess the Degradation Risk of Photovoltaic Systems\",\"authors\":\"A. C. Ciocea F. Munteanu C. Nemes, F. Munteanu, C. Nemeş\",\"doi\":\"10.1109/ICEPE.2018.8559803\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper presents the failure modes, the effects and the criticality for each element in the architecture and operation of a photovoltaic system. A typical configuration is considered: photovoltaic panel, junction box, connection cables, controller, battery and inverter. The first part of this study generally describes the current state of the failure modes and effects for each element of the photovoltaic system. In the second part of the study is presented a structured case study based on the LACARP photovoltaic system that is part of LACARP’s laboratory of Faculty of Electrical Engineering of the “Gheorghe Asachi” Technical University of Iasi including customized criteria and indicators for each element of a photovoltaic system. This approach will help establishing the hierarchy and the integration of each failure mode and the level of rated power affected.\",\"PeriodicalId\":343896,\"journal\":{\"name\":\"2018 International Conference and Exposition on Electrical And Power Engineering (EPE)\",\"volume\":\"41 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 International Conference and Exposition on Electrical And Power Engineering (EPE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICEPE.2018.8559803\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 International Conference and Exposition on Electrical And Power Engineering (EPE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEPE.2018.8559803","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文介绍了光伏系统结构和运行中各部件的失效模式、影响和临界性。考虑一个典型的配置:光伏板,接线盒,连接电缆,控制器,电池和逆变器。本研究的第一部分概述了光伏系统各部件失效模式的现状及影响。在研究的第二部分,提出了一个基于LACARP光伏系统的结构化案例研究,该系统是雅西“Gheorghe Asachi”工业大学电气工程学院LACARP实验室的一部分,包括光伏系统每个元素的定制标准和指标。这种方法将有助于建立层次结构和每个故障模式的集成以及受影响的额定功率水平。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Method to Assess the Degradation Risk of Photovoltaic Systems
The paper presents the failure modes, the effects and the criticality for each element in the architecture and operation of a photovoltaic system. A typical configuration is considered: photovoltaic panel, junction box, connection cables, controller, battery and inverter. The first part of this study generally describes the current state of the failure modes and effects for each element of the photovoltaic system. In the second part of the study is presented a structured case study based on the LACARP photovoltaic system that is part of LACARP’s laboratory of Faculty of Electrical Engineering of the “Gheorghe Asachi” Technical University of Iasi including customized criteria and indicators for each element of a photovoltaic system. This approach will help establishing the hierarchy and the integration of each failure mode and the level of rated power affected.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Emotion Analysis Architecture Based on Face and Physiological Sensing Applied with Flight Simulator Analysis of Light Design in the Lighting Laboratory of the Riga Technical University Morphological, Physiological and Productive Indicators of Lettuce under Non-thermal Plasma Coherence and Continuity in the Continuing Education of Electrical and Energetic Field Teachers from the Pre-University Environment Solution to improve the quality of electricity in low voltage networks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1