Ajit J Kalia, Juhi Joshi, Mohammed Mandsaurwala, Sayali Bobade, Azmat Azha Khan
{"title":"美观的镍钛线——它们能产生同样的力吗?","authors":"Ajit J Kalia, Juhi Joshi, Mohammed Mandsaurwala, Sayali Bobade, Azmat Azha Khan","doi":"10.18231/j.ijodr.2022.045","DOIUrl":null,"url":null,"abstract":"To test the difference in loading and unloading forces delivered by six coated nickel-titanium wires and their non-coated equivalents. Commercially available six coated nickel-titanium wires and their non-coated equivalents of sizes 0.016-inch diameter round and 0.016 X 0.022-inch rectangular cross-section were procured. The wires were evaluated using a three-point bending test based on the method in ISO Standard 15841. No statistically significant differences in force values were found between coated and non-coated wires, listed by deflection in three-point bending, for these specific groups.Statistical analysis was done using SPSS version 11.5 (Chicago, III). Analysis of variance was performed with Sheffe post hoc for the mean comparison among the measurements of each loading and unloading deflection for coated and non-coated wires. Student’s t-tests was performed for the mean comparisons between non coated and coated groups for each deflection. There is no significant difference in load response between coated and non-coated nickel-titanium wires of the same size when subjected to the same deflection using a standard three-point bend test method.","PeriodicalId":269485,"journal":{"name":"IP Indian Journal of Orthodontics and Dentofacial Research","volume":"42 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-12-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Esthetic nickel titanium wires– Do they deliver the same force?\",\"authors\":\"Ajit J Kalia, Juhi Joshi, Mohammed Mandsaurwala, Sayali Bobade, Azmat Azha Khan\",\"doi\":\"10.18231/j.ijodr.2022.045\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"To test the difference in loading and unloading forces delivered by six coated nickel-titanium wires and their non-coated equivalents. Commercially available six coated nickel-titanium wires and their non-coated equivalents of sizes 0.016-inch diameter round and 0.016 X 0.022-inch rectangular cross-section were procured. The wires were evaluated using a three-point bending test based on the method in ISO Standard 15841. No statistically significant differences in force values were found between coated and non-coated wires, listed by deflection in three-point bending, for these specific groups.Statistical analysis was done using SPSS version 11.5 (Chicago, III). Analysis of variance was performed with Sheffe post hoc for the mean comparison among the measurements of each loading and unloading deflection for coated and non-coated wires. Student’s t-tests was performed for the mean comparisons between non coated and coated groups for each deflection. There is no significant difference in load response between coated and non-coated nickel-titanium wires of the same size when subjected to the same deflection using a standard three-point bend test method.\",\"PeriodicalId\":269485,\"journal\":{\"name\":\"IP Indian Journal of Orthodontics and Dentofacial Research\",\"volume\":\"42 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-12-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IP Indian Journal of Orthodontics and Dentofacial Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.18231/j.ijodr.2022.045\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IP Indian Journal of Orthodontics and Dentofacial Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18231/j.ijodr.2022.045","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
测试六根涂覆镍钛线和未涂覆镍钛线所产生的载荷和卸载力的差异。市售的六根涂覆镍钛线及其未涂覆的等价物直径为0.016英寸的圆形和0.016 X 0.022英寸的矩形截面。使用基于ISO标准15841方法的三点弯曲试验对钢丝进行评估。在这些特定组中,根据三点弯曲挠度列出的涂覆和非涂覆导线之间的力值没有统计学上的显着差异。使用SPSS 11.5 (Chicago, III)进行统计分析。使用Sheffe post hoc进行方差分析,对涂覆和非涂覆导线每次加载和卸载挠度的测量值进行平均值比较。对每次偏转的非涂覆组和涂覆组之间的平均比较进行学生t检验。采用标准三点弯曲试验方法,相同尺寸的涂覆镍钛线与未涂覆镍钛线在受到相同挠度时的负载响应无显著差异。
Esthetic nickel titanium wires– Do they deliver the same force?
To test the difference in loading and unloading forces delivered by six coated nickel-titanium wires and their non-coated equivalents. Commercially available six coated nickel-titanium wires and their non-coated equivalents of sizes 0.016-inch diameter round and 0.016 X 0.022-inch rectangular cross-section were procured. The wires were evaluated using a three-point bending test based on the method in ISO Standard 15841. No statistically significant differences in force values were found between coated and non-coated wires, listed by deflection in three-point bending, for these specific groups.Statistical analysis was done using SPSS version 11.5 (Chicago, III). Analysis of variance was performed with Sheffe post hoc for the mean comparison among the measurements of each loading and unloading deflection for coated and non-coated wires. Student’s t-tests was performed for the mean comparisons between non coated and coated groups for each deflection. There is no significant difference in load response between coated and non-coated nickel-titanium wires of the same size when subjected to the same deflection using a standard three-point bend test method.