美观的镍钛线——它们能产生同样的力吗?

Ajit J Kalia, Juhi Joshi, Mohammed Mandsaurwala, Sayali Bobade, Azmat Azha Khan
{"title":"美观的镍钛线——它们能产生同样的力吗?","authors":"Ajit J Kalia, Juhi Joshi, Mohammed Mandsaurwala, Sayali Bobade, Azmat Azha Khan","doi":"10.18231/j.ijodr.2022.045","DOIUrl":null,"url":null,"abstract":"To test the difference in loading and unloading forces delivered by six coated nickel-titanium wires and their non-coated equivalents. Commercially available six coated nickel-titanium wires and their non-coated equivalents of sizes 0.016-inch diameter round and 0.016 X 0.022-inch rectangular cross-section were procured. The wires were evaluated using a three-point bending test based on the method in ISO Standard 15841. No statistically significant differences in force values were found between coated and non-coated wires, listed by deflection in three-point bending, for these specific groups.Statistical analysis was done using SPSS version 11.5 (Chicago, III). Analysis of variance was performed with Sheffe post hoc for the mean comparison among the measurements of each loading and unloading deflection for coated and non-coated wires. Student’s t-tests was performed for the mean comparisons between non coated and coated groups for each deflection. There is no significant difference in load response between coated and non-coated nickel-titanium wires of the same size when subjected to the same deflection using a standard three-point bend test method.","PeriodicalId":269485,"journal":{"name":"IP Indian Journal of Orthodontics and Dentofacial Research","volume":"42 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-12-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Esthetic nickel titanium wires– Do they deliver the same force?\",\"authors\":\"Ajit J Kalia, Juhi Joshi, Mohammed Mandsaurwala, Sayali Bobade, Azmat Azha Khan\",\"doi\":\"10.18231/j.ijodr.2022.045\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"To test the difference in loading and unloading forces delivered by six coated nickel-titanium wires and their non-coated equivalents. Commercially available six coated nickel-titanium wires and their non-coated equivalents of sizes 0.016-inch diameter round and 0.016 X 0.022-inch rectangular cross-section were procured. The wires were evaluated using a three-point bending test based on the method in ISO Standard 15841. No statistically significant differences in force values were found between coated and non-coated wires, listed by deflection in three-point bending, for these specific groups.Statistical analysis was done using SPSS version 11.5 (Chicago, III). Analysis of variance was performed with Sheffe post hoc for the mean comparison among the measurements of each loading and unloading deflection for coated and non-coated wires. Student’s t-tests was performed for the mean comparisons between non coated and coated groups for each deflection. There is no significant difference in load response between coated and non-coated nickel-titanium wires of the same size when subjected to the same deflection using a standard three-point bend test method.\",\"PeriodicalId\":269485,\"journal\":{\"name\":\"IP Indian Journal of Orthodontics and Dentofacial Research\",\"volume\":\"42 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-12-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IP Indian Journal of Orthodontics and Dentofacial Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.18231/j.ijodr.2022.045\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IP Indian Journal of Orthodontics and Dentofacial Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18231/j.ijodr.2022.045","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

测试六根涂覆镍钛线和未涂覆镍钛线所产生的载荷和卸载力的差异。市售的六根涂覆镍钛线及其未涂覆的等价物直径为0.016英寸的圆形和0.016 X 0.022英寸的矩形截面。使用基于ISO标准15841方法的三点弯曲试验对钢丝进行评估。在这些特定组中,根据三点弯曲挠度列出的涂覆和非涂覆导线之间的力值没有统计学上的显着差异。使用SPSS 11.5 (Chicago, III)进行统计分析。使用Sheffe post hoc进行方差分析,对涂覆和非涂覆导线每次加载和卸载挠度的测量值进行平均值比较。对每次偏转的非涂覆组和涂覆组之间的平均比较进行学生t检验。采用标准三点弯曲试验方法,相同尺寸的涂覆镍钛线与未涂覆镍钛线在受到相同挠度时的负载响应无显著差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Esthetic nickel titanium wires– Do they deliver the same force?
To test the difference in loading and unloading forces delivered by six coated nickel-titanium wires and their non-coated equivalents. Commercially available six coated nickel-titanium wires and their non-coated equivalents of sizes 0.016-inch diameter round and 0.016 X 0.022-inch rectangular cross-section were procured. The wires were evaluated using a three-point bending test based on the method in ISO Standard 15841. No statistically significant differences in force values were found between coated and non-coated wires, listed by deflection in three-point bending, for these specific groups.Statistical analysis was done using SPSS version 11.5 (Chicago, III). Analysis of variance was performed with Sheffe post hoc for the mean comparison among the measurements of each loading and unloading deflection for coated and non-coated wires. Student’s t-tests was performed for the mean comparisons between non coated and coated groups for each deflection. There is no significant difference in load response between coated and non-coated nickel-titanium wires of the same size when subjected to the same deflection using a standard three-point bend test method.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Management of skeletal Class III malocclusion using two-phase therapy in young patient - A case report CBCT: The third eye in orthodontics Comparison between two types of grids for placement of mini-screw implant in posterior maxillary segment Evaluation of surface-modified orthodontic brackets with silver nanoparticles and its influence on bacterial inhibition – An in vitro study Deep bite -An insight
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1