Pengfei Wang, M. Ding, G. Brambilla, Y. Semenova, Qiang Wu, G. Farrell
{"title":"利用光纤耦合器提高比率波长测量系统的分辨率","authors":"Pengfei Wang, M. Ding, G. Brambilla, Y. Semenova, Qiang Wu, G. Farrell","doi":"10.1109/SOPO.2012.6270563","DOIUrl":null,"url":null,"abstract":"The application of microfibre couplers in a comb-filter-based ratiometric wavelength measurement system is discussed. The fabrication of microfibre coupler is presented and its temperature-dependent performance is investigated. The resolution of the ratiometric wavelength measurement system with a microfiber coupler is significantly improved in comparison with a conventional ratiometric system to better than 4 pm maintaining the potential for high measurement speed and wide measurable wavelength range.","PeriodicalId":159850,"journal":{"name":"2012 Symposium on Photonics and Optoelectronics","volume":"97 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-05-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Resolution Improvement of a Ratiometric Wavelength Measurement System by Using an Optical Microfibre Coupler\",\"authors\":\"Pengfei Wang, M. Ding, G. Brambilla, Y. Semenova, Qiang Wu, G. Farrell\",\"doi\":\"10.1109/SOPO.2012.6270563\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The application of microfibre couplers in a comb-filter-based ratiometric wavelength measurement system is discussed. The fabrication of microfibre coupler is presented and its temperature-dependent performance is investigated. The resolution of the ratiometric wavelength measurement system with a microfiber coupler is significantly improved in comparison with a conventional ratiometric system to better than 4 pm maintaining the potential for high measurement speed and wide measurable wavelength range.\",\"PeriodicalId\":159850,\"journal\":{\"name\":\"2012 Symposium on Photonics and Optoelectronics\",\"volume\":\"97 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-05-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 Symposium on Photonics and Optoelectronics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SOPO.2012.6270563\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 Symposium on Photonics and Optoelectronics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SOPO.2012.6270563","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Resolution Improvement of a Ratiometric Wavelength Measurement System by Using an Optical Microfibre Coupler
The application of microfibre couplers in a comb-filter-based ratiometric wavelength measurement system is discussed. The fabrication of microfibre coupler is presented and its temperature-dependent performance is investigated. The resolution of the ratiometric wavelength measurement system with a microfiber coupler is significantly improved in comparison with a conventional ratiometric system to better than 4 pm maintaining the potential for high measurement speed and wide measurable wavelength range.