{"title":"基于LabView的光分布分析实验集","authors":"J. Sarasook, C. Thongchaisuratkrul","doi":"10.1109/ICAICTA.2018.8541332","DOIUrl":null,"url":null,"abstract":"This research presents experimental set of distribution light. Light illuminance is displayed by LabView application. The set was tested by four types of lamp including complex fluorescent (CFL), incandescent, E27 LED (Light Emitting Diode), T8 tubular fluorescent (FL). The 3 types of luminaire are used for testing. They consisted of down light, high bay and fluorescent reflector. The black close room was 1.5x1.5x1.5 m in size. It was constructed by steel and plywood. The center floor of the room is installed by LDR (Light Dependent Resistor). It was used for measuring the illuminance. LabView application was applied to display value on computer screen. The stepping motor was installed to rotate the lamp. It was controlled by LabView through DAQ 6008 interface card. It was rotated from -90o to 90o. The control set consisted of interface card, motor drive and power supply. They were contained in the insulation box outside of the test room. From the experimental result, the LDR illuminance meter can measure illuminance with 4.52% average error. The light distribution curve from experiment set is correspondent with theory.","PeriodicalId":184882,"journal":{"name":"2018 5th International Conference on Advanced Informatics: Concept Theory and Applications (ICAICTA)","volume":"8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Experimental Set of Light Distribution Analysis by LabView Application\",\"authors\":\"J. Sarasook, C. Thongchaisuratkrul\",\"doi\":\"10.1109/ICAICTA.2018.8541332\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This research presents experimental set of distribution light. Light illuminance is displayed by LabView application. The set was tested by four types of lamp including complex fluorescent (CFL), incandescent, E27 LED (Light Emitting Diode), T8 tubular fluorescent (FL). The 3 types of luminaire are used for testing. They consisted of down light, high bay and fluorescent reflector. The black close room was 1.5x1.5x1.5 m in size. It was constructed by steel and plywood. The center floor of the room is installed by LDR (Light Dependent Resistor). It was used for measuring the illuminance. LabView application was applied to display value on computer screen. The stepping motor was installed to rotate the lamp. It was controlled by LabView through DAQ 6008 interface card. It was rotated from -90o to 90o. The control set consisted of interface card, motor drive and power supply. They were contained in the insulation box outside of the test room. From the experimental result, the LDR illuminance meter can measure illuminance with 4.52% average error. The light distribution curve from experiment set is correspondent with theory.\",\"PeriodicalId\":184882,\"journal\":{\"name\":\"2018 5th International Conference on Advanced Informatics: Concept Theory and Applications (ICAICTA)\",\"volume\":\"8 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 5th International Conference on Advanced Informatics: Concept Theory and Applications (ICAICTA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICAICTA.2018.8541332\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 5th International Conference on Advanced Informatics: Concept Theory and Applications (ICAICTA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICAICTA.2018.8541332","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
本研究提出一套配电灯实验装置。光源照度由LabView应用程序显示。采用复合荧光灯(CFL)、白炽灯、E27 LED (Light Emitting Diode)、T8管状荧光灯(FL)四种灯进行测试。测试使用3种类型的灯具。它们由筒灯、高舱和荧光反射器组成。黑色的密室尺寸为1.5x1.5x1.5 m。它是由钢和胶合板建造的。房间的中央楼层安装了LDR(光依赖电阻)。它被用来测量照度。应用LabView程序在计算机屏幕上显示数值。安装步进电机使灯转动。LabView通过DAQ 6008接口卡对其进行控制。它从-90度旋转到90度。控制装置由接口卡、电机驱动和电源组成。它们被装在测试室外的绝缘盒里。实验结果表明,LDR照度计测量照度的平均误差为4.52%。实验所得的配光曲线与理论相符。
The Experimental Set of Light Distribution Analysis by LabView Application
This research presents experimental set of distribution light. Light illuminance is displayed by LabView application. The set was tested by four types of lamp including complex fluorescent (CFL), incandescent, E27 LED (Light Emitting Diode), T8 tubular fluorescent (FL). The 3 types of luminaire are used for testing. They consisted of down light, high bay and fluorescent reflector. The black close room was 1.5x1.5x1.5 m in size. It was constructed by steel and plywood. The center floor of the room is installed by LDR (Light Dependent Resistor). It was used for measuring the illuminance. LabView application was applied to display value on computer screen. The stepping motor was installed to rotate the lamp. It was controlled by LabView through DAQ 6008 interface card. It was rotated from -90o to 90o. The control set consisted of interface card, motor drive and power supply. They were contained in the insulation box outside of the test room. From the experimental result, the LDR illuminance meter can measure illuminance with 4.52% average error. The light distribution curve from experiment set is correspondent with theory.