电磁颈椎活动范围系统的设计与开发

M. Schendel, R. Patterson, J. Allison
{"title":"电磁颈椎活动范围系统的设计与开发","authors":"M. Schendel, R. Patterson, J. Allison","doi":"10.1109/IEMBS.1988.94754","DOIUrl":null,"url":null,"abstract":"A three-dimensional cervical-spine range-of-motion system has been developed using an electromagnetic tracking system for data collection and a personal computer for analysis and graphic representation of the data. A test was designed to investigate the sensitivity of the electromagnetic device to the proximity of metal. It was found that relative position errors could be kept below 0.5 cm and rotation errors could be kept below 1 degrees if all metal was at least 33 cm from the source and sensor and the source was kept at least 33 cm from the floor.<<ETX>>","PeriodicalId":227170,"journal":{"name":"Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1988-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Design and development of an electromagnetic cervical range of motion system\",\"authors\":\"M. Schendel, R. Patterson, J. Allison\",\"doi\":\"10.1109/IEMBS.1988.94754\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A three-dimensional cervical-spine range-of-motion system has been developed using an electromagnetic tracking system for data collection and a personal computer for analysis and graphic representation of the data. A test was designed to investigate the sensitivity of the electromagnetic device to the proximity of metal. It was found that relative position errors could be kept below 0.5 cm and rotation errors could be kept below 1 degrees if all metal was at least 33 cm from the source and sensor and the source was kept at least 33 cm from the floor.<<ETX>>\",\"PeriodicalId\":227170,\"journal\":{\"name\":\"Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1988-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IEMBS.1988.94754\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IEMBS.1988.94754","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

利用电磁跟踪系统收集数据,利用个人计算机对数据进行分析和图形化表示,开发了一个三维颈椎活动范围系统。设计了一个试验来研究电磁装置对接近金属的灵敏度。研究发现,如果所有金属距离源和传感器至少33厘米,源距离地面至少33厘米,相对位置误差可以保持在0.5厘米以下,旋转误差可以保持在1度以下。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Design and development of an electromagnetic cervical range of motion system
A three-dimensional cervical-spine range-of-motion system has been developed using an electromagnetic tracking system for data collection and a personal computer for analysis and graphic representation of the data. A test was designed to investigate the sensitivity of the electromagnetic device to the proximity of metal. It was found that relative position errors could be kept below 0.5 cm and rotation errors could be kept below 1 degrees if all metal was at least 33 cm from the source and sensor and the source was kept at least 33 cm from the floor.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Prognostic value of morphometry in papillary thyroid carcinoma An expert system approach to cystic fibrosis patient management Design and development of an electromagnetic cervical range of motion system EMG pattern classification of normal and anterior cruciate ligament injured subjects On-line system for automated auditory evoked response threshold determination
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1