K. Tarchanidis, J. Lygouras, T. Pachidis, V. Kodogiannis, C. Chatziandreoglou
{"title":"通过互联网进行pH中和","authors":"K. Tarchanidis, J. Lygouras, T. Pachidis, V. Kodogiannis, C. Chatziandreoglou","doi":"10.1109/VECIMS.2006.250782","DOIUrl":null,"url":null,"abstract":"This project uses an IDAC-1 board to sample and control the pH level in a tank. The whole control is performed through the Internet. The experimental arrangement is placed on the task location and the controlling computer is located in a different one. Internet is the transport media. The protocol used in this project is UDP/IP. The pH level is measured by a pH meter and its output is sampled by an A/D converter integrated on the IDAC-1. To change the pH level ON-OFF valves control the free flow of light solutions acid and alkaline. The controlling computer through the Internet acting as client asks for the pH level, the IDAC-1 responds as server with the 10-bit resolution sampling pH meter. If pH is away from the set point the corresponding valve opens, neutralizing this way the solution. The whole procedure is logged in a file on the controlling computer. This application can give the ability to the Internet user to monitor and control the pH of a solution anywhere in the Word Wide Web (WWW)","PeriodicalId":405572,"journal":{"name":"2006 IEEE Symposium on Virtual Environments, Human-Computer Interfaces and Measurement Systems","volume":"421 2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-07-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"pH Neutralization Through Internet\",\"authors\":\"K. Tarchanidis, J. Lygouras, T. Pachidis, V. Kodogiannis, C. Chatziandreoglou\",\"doi\":\"10.1109/VECIMS.2006.250782\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This project uses an IDAC-1 board to sample and control the pH level in a tank. The whole control is performed through the Internet. The experimental arrangement is placed on the task location and the controlling computer is located in a different one. Internet is the transport media. The protocol used in this project is UDP/IP. The pH level is measured by a pH meter and its output is sampled by an A/D converter integrated on the IDAC-1. To change the pH level ON-OFF valves control the free flow of light solutions acid and alkaline. The controlling computer through the Internet acting as client asks for the pH level, the IDAC-1 responds as server with the 10-bit resolution sampling pH meter. If pH is away from the set point the corresponding valve opens, neutralizing this way the solution. The whole procedure is logged in a file on the controlling computer. This application can give the ability to the Internet user to monitor and control the pH of a solution anywhere in the Word Wide Web (WWW)\",\"PeriodicalId\":405572,\"journal\":{\"name\":\"2006 IEEE Symposium on Virtual Environments, Human-Computer Interfaces and Measurement Systems\",\"volume\":\"421 2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-07-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2006 IEEE Symposium on Virtual Environments, Human-Computer Interfaces and Measurement Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/VECIMS.2006.250782\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 IEEE Symposium on Virtual Environments, Human-Computer Interfaces and Measurement Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/VECIMS.2006.250782","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
This project uses an IDAC-1 board to sample and control the pH level in a tank. The whole control is performed through the Internet. The experimental arrangement is placed on the task location and the controlling computer is located in a different one. Internet is the transport media. The protocol used in this project is UDP/IP. The pH level is measured by a pH meter and its output is sampled by an A/D converter integrated on the IDAC-1. To change the pH level ON-OFF valves control the free flow of light solutions acid and alkaline. The controlling computer through the Internet acting as client asks for the pH level, the IDAC-1 responds as server with the 10-bit resolution sampling pH meter. If pH is away from the set point the corresponding valve opens, neutralizing this way the solution. The whole procedure is logged in a file on the controlling computer. This application can give the ability to the Internet user to monitor and control the pH of a solution anywhere in the Word Wide Web (WWW)