颈动脉分叉的结构和弹性的三维超声成像

J. R. Jackson, P. Benkeser, F. Nichols
{"title":"颈动脉分叉的结构和弹性的三维超声成像","authors":"J. R. Jackson, P. Benkeser, F. Nichols","doi":"10.1109/ULTSYM.1995.495821","DOIUrl":null,"url":null,"abstract":"The long-term goal of this work is to develop an ultrasound technique that produces a 3-D image of the structure and elasticity of the cervical common carotid artery and its bifurcation, allowing the quantitative measurement of the volume, structure and composition of atherosclerotic plaque at or near the bifurcation. An Acuson 128 imaging system was used to obtain time-gated B-mode images of the carotid in vivo. The motion of the vessel wall due to the changing blood pressure during a cardiac cycle was quantified and used to compute an estimate of the tissue elasticity distribution over each 2-D image plane. The tissue motion direction and amplitude was determined by a 2-D interframe block matching technique performed on a sequence of frames acquired at 18 frames per second. The transducer was moved linearly along the axis of the common carotid in 2 mm increments to collect the set of slices used to form the 3-D image. Volumetric images of the phantom have been made. Elasticity measurements indicate that the tissue motion appears to be an adequate measure for the determination of relative elasticity distributions.","PeriodicalId":268177,"journal":{"name":"1995 IEEE Ultrasonics Symposium. Proceedings. An International Symposium","volume":"23 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1995-11-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"3-D ultrasonic imaging of the structure and elasticity of the carotid bifurcation\",\"authors\":\"J. R. Jackson, P. Benkeser, F. Nichols\",\"doi\":\"10.1109/ULTSYM.1995.495821\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The long-term goal of this work is to develop an ultrasound technique that produces a 3-D image of the structure and elasticity of the cervical common carotid artery and its bifurcation, allowing the quantitative measurement of the volume, structure and composition of atherosclerotic plaque at or near the bifurcation. An Acuson 128 imaging system was used to obtain time-gated B-mode images of the carotid in vivo. The motion of the vessel wall due to the changing blood pressure during a cardiac cycle was quantified and used to compute an estimate of the tissue elasticity distribution over each 2-D image plane. The tissue motion direction and amplitude was determined by a 2-D interframe block matching technique performed on a sequence of frames acquired at 18 frames per second. The transducer was moved linearly along the axis of the common carotid in 2 mm increments to collect the set of slices used to form the 3-D image. Volumetric images of the phantom have been made. Elasticity measurements indicate that the tissue motion appears to be an adequate measure for the determination of relative elasticity distributions.\",\"PeriodicalId\":268177,\"journal\":{\"name\":\"1995 IEEE Ultrasonics Symposium. Proceedings. An International Symposium\",\"volume\":\"23 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1995-11-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1995 IEEE Ultrasonics Symposium. Proceedings. An International Symposium\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ULTSYM.1995.495821\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1995 IEEE Ultrasonics Symposium. Proceedings. An International Symposium","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ULTSYM.1995.495821","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

这项工作的长期目标是开发一种超声技术,该技术可以产生颈总动脉及其分支的结构和弹性的三维图像,从而可以定量测量分支处或附近的动脉粥样硬化斑块的体积、结构和组成。使用Acuson 128成像系统获得活体颈动脉的时间门控b模式图像。在心脏周期中,由于血压变化引起的血管壁运动被量化,并用于计算每个二维图像平面上组织弹性分布的估计。组织的运动方向和幅度是通过二维帧间块匹配技术确定的,该技术对每秒18帧的帧序列进行匹配。传感器沿颈总动脉轴线以2mm的增量线性移动,以收集用于形成3d图像的一组切片。幻影的体积图像已经制作完成。弹性测量表明,组织运动似乎是确定相对弹性分布的适当措施。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
3-D ultrasonic imaging of the structure and elasticity of the carotid bifurcation
The long-term goal of this work is to develop an ultrasound technique that produces a 3-D image of the structure and elasticity of the cervical common carotid artery and its bifurcation, allowing the quantitative measurement of the volume, structure and composition of atherosclerotic plaque at or near the bifurcation. An Acuson 128 imaging system was used to obtain time-gated B-mode images of the carotid in vivo. The motion of the vessel wall due to the changing blood pressure during a cardiac cycle was quantified and used to compute an estimate of the tissue elasticity distribution over each 2-D image plane. The tissue motion direction and amplitude was determined by a 2-D interframe block matching technique performed on a sequence of frames acquired at 18 frames per second. The transducer was moved linearly along the axis of the common carotid in 2 mm increments to collect the set of slices used to form the 3-D image. Volumetric images of the phantom have been made. Elasticity measurements indicate that the tissue motion appears to be an adequate measure for the determination of relative elasticity distributions.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
50 MHz color flow mapping Temporal correlation of blood scattering signals from intravascular ultrasound Two-dimensional modeling of multifrequency composites Electric field forced vibration of a periodic piezocomposite plate with laminated structure and reflection and transmission of a plane wave at the fluid-composite interface Mechanical loading effect of rectangularly-shaped shallow electrodes on SAW devices
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1