柔性血管内热传感器评估动脉粥样硬化介导的血流动力学变化

Juhyun Lee, N. Jen, Fei Yu, W. Dai, Hongyu Yu, T. Hsiai
{"title":"柔性血管内热传感器评估动脉粥样硬化介导的血流动力学变化","authors":"Juhyun Lee, N. Jen, Fei Yu, W. Dai, Hongyu Yu, T. Hsiai","doi":"10.1109/PAHCE.2012.6233431","DOIUrl":null,"url":null,"abstract":"In this study, we introduced an in vivo convective heat transfer-based micro-electromechanical system (MEMS) sensor that measured real-time experimental vascular shear stress values in the aortas of New Zealand White rabbits (n=4). Experiments were performed to measure flow profile changes in response to hyper-cholesterol diet and an irregular tachycardia condition. We have shown that these conditions induce shear stress changes indicative of pre-atherosclerosis regions by the MEMS thermal sensor.","PeriodicalId":255935,"journal":{"name":"2012 Pan American Health Care Exchanges","volume":"23 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-03-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Flexible intravascular thermal sensors to assess atherosclerosis-mediated changes in hemodynamics\",\"authors\":\"Juhyun Lee, N. Jen, Fei Yu, W. Dai, Hongyu Yu, T. Hsiai\",\"doi\":\"10.1109/PAHCE.2012.6233431\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this study, we introduced an in vivo convective heat transfer-based micro-electromechanical system (MEMS) sensor that measured real-time experimental vascular shear stress values in the aortas of New Zealand White rabbits (n=4). Experiments were performed to measure flow profile changes in response to hyper-cholesterol diet and an irregular tachycardia condition. We have shown that these conditions induce shear stress changes indicative of pre-atherosclerosis regions by the MEMS thermal sensor.\",\"PeriodicalId\":255935,\"journal\":{\"name\":\"2012 Pan American Health Care Exchanges\",\"volume\":\"23 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-03-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 Pan American Health Care Exchanges\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PAHCE.2012.6233431\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 Pan American Health Care Exchanges","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PAHCE.2012.6233431","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在这项研究中,我们引入了一种基于体内对流传热的微机电系统(MEMS)传感器,用于实时测量新西兰大白兔(n=4)主动脉血管剪切应力的实验值。实验测量了高胆固醇饮食和不规则心动过速情况下血流剖面的变化。我们已经通过MEMS热传感器表明,这些条件诱导了指示动脉粥样硬化前区域的剪切应力变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Flexible intravascular thermal sensors to assess atherosclerosis-mediated changes in hemodynamics
In this study, we introduced an in vivo convective heat transfer-based micro-electromechanical system (MEMS) sensor that measured real-time experimental vascular shear stress values in the aortas of New Zealand White rabbits (n=4). Experiments were performed to measure flow profile changes in response to hyper-cholesterol diet and an irregular tachycardia condition. We have shown that these conditions induce shear stress changes indicative of pre-atherosclerosis regions by the MEMS thermal sensor.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Wigner distribution's cross terms characterization to detect patterns of Ventricular Late Potentials Study of the noise-ventricular late potentials sensibility on the wigner distribution time-frequency plane Simulation of the left coronay flow Flexible intravascular thermal sensors to assess atherosclerosis-mediated changes in hemodynamics Inventory quality control in clinical engineering: A Lean Six Sigma approach
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1