动物PET的设计:灵活的几何形状,实现最佳的空间分辨率或高灵敏度

S. Weber, A. Terstegge, H. Halling, H. Herzog, R. Reinartz, P. Reinhart, F. Rongen, H. Muller-Gartner
{"title":"动物PET的设计:灵活的几何形状,实现最佳的空间分辨率或高灵敏度","authors":"S. Weber, A. Terstegge, H. Halling, H. Herzog, R. Reinartz, P. Reinhart, F. Rongen, H. Muller-Gartner","doi":"10.1109/NSSMIC.1995.510435","DOIUrl":null,"url":null,"abstract":"A positron emission tomograph (PET) for small animals, e.g. rabbits or rats, is under development at the KFA Juelich as a cooperative effort between the Institute of Medicine which includes a PET center, the Central Laboratory for Electronics and the Institute for Thin Film and Ion Technology (ISI). The first version of the scanner uses arrays of small individual Yttrium Aluminium Perovskit (YAP) scintillator crystals coupled to position sensitive photomultiplier tubes. Special hardware has been built for coincidence detection, position detection and real time data acquisition, which is performed by a PC. The single event data are transfered to workstations, where the radioactivity distribution is reconstructed. The fundamental design features have extensively been simulated. Preliminary studies were carried out by using single NaI:Tl crystals coupled to position sensitive photomultiplier tubes. For the reconstruction of the simulated source configurations and measured data a 3D EM-algorithm has been implemented. The main advantage of the animal PET scanner is its high flexibility, allowing the realization of various detector system configurations. The system is capable of either providing good spatial resolution or high sensitivity for dynamic studies of pharmacokinetics. The reconstruction software is flexible and matches the different choices.","PeriodicalId":409998,"journal":{"name":"1995 IEEE Nuclear Science Symposium and Medical Imaging Conference Record","volume":"41 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1995-10-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"The design of an animal PET: flexible geometry for achieving optimal spatial resolution or high sensitivity\",\"authors\":\"S. Weber, A. Terstegge, H. Halling, H. Herzog, R. Reinartz, P. Reinhart, F. Rongen, H. Muller-Gartner\",\"doi\":\"10.1109/NSSMIC.1995.510435\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A positron emission tomograph (PET) for small animals, e.g. rabbits or rats, is under development at the KFA Juelich as a cooperative effort between the Institute of Medicine which includes a PET center, the Central Laboratory for Electronics and the Institute for Thin Film and Ion Technology (ISI). The first version of the scanner uses arrays of small individual Yttrium Aluminium Perovskit (YAP) scintillator crystals coupled to position sensitive photomultiplier tubes. Special hardware has been built for coincidence detection, position detection and real time data acquisition, which is performed by a PC. The single event data are transfered to workstations, where the radioactivity distribution is reconstructed. The fundamental design features have extensively been simulated. Preliminary studies were carried out by using single NaI:Tl crystals coupled to position sensitive photomultiplier tubes. For the reconstruction of the simulated source configurations and measured data a 3D EM-algorithm has been implemented. The main advantage of the animal PET scanner is its high flexibility, allowing the realization of various detector system configurations. The system is capable of either providing good spatial resolution or high sensitivity for dynamic studies of pharmacokinetics. The reconstruction software is flexible and matches the different choices.\",\"PeriodicalId\":409998,\"journal\":{\"name\":\"1995 IEEE Nuclear Science Symposium and Medical Imaging Conference Record\",\"volume\":\"41 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1995-10-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1995 IEEE Nuclear Science Symposium and Medical Imaging Conference Record\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSSMIC.1995.510435\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1995 IEEE Nuclear Science Symposium and Medical Imaging Conference Record","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.1995.510435","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

KFA Juelich正在开发一种用于小动物(如兔子或老鼠)的正电子发射断层扫描(PET),这是医学研究所(包括PET中心)、电子中心实验室和薄膜与离子技术研究所(ISI)之间的合作。第一个版本的扫描仪使用小型单个钇铝钙钛矿(YAP)闪烁晶体阵列耦合来定位敏感的光电倍增管。设计了符合检测、位置检测和实时数据采集的专用硬件,由PC机完成。单个事件的数据被传送到工作站,在那里重建放射性分布。基本的设计特征已经被广泛地模拟。初步的研究是利用单一的NaI:Tl晶体偶联来定位敏感的光电倍增管。为了重建模拟源结构和测量数据,实现了一种三维电磁算法。动物PET扫描仪的主要优点是灵活性高,可实现各种检测系统配置。该系统能够为药代动力学的动态研究提供良好的空间分辨率和高灵敏度。重建软件是灵活的,并匹配不同的选择。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The design of an animal PET: flexible geometry for achieving optimal spatial resolution or high sensitivity
A positron emission tomograph (PET) for small animals, e.g. rabbits or rats, is under development at the KFA Juelich as a cooperative effort between the Institute of Medicine which includes a PET center, the Central Laboratory for Electronics and the Institute for Thin Film and Ion Technology (ISI). The first version of the scanner uses arrays of small individual Yttrium Aluminium Perovskit (YAP) scintillator crystals coupled to position sensitive photomultiplier tubes. Special hardware has been built for coincidence detection, position detection and real time data acquisition, which is performed by a PC. The single event data are transfered to workstations, where the radioactivity distribution is reconstructed. The fundamental design features have extensively been simulated. Preliminary studies were carried out by using single NaI:Tl crystals coupled to position sensitive photomultiplier tubes. For the reconstruction of the simulated source configurations and measured data a 3D EM-algorithm has been implemented. The main advantage of the animal PET scanner is its high flexibility, allowing the realization of various detector system configurations. The system is capable of either providing good spatial resolution or high sensitivity for dynamic studies of pharmacokinetics. The reconstruction software is flexible and matches the different choices.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The performance of the DELPHI Hadron Calorimeter at LEP AlGaAs/GaAs avalanche detector array -1 GBit/s X-ray receiver for timing measurements Parallelization of 3-D PET BpjF reconstruction on a DSP cluster Noise analysis of low noise, high count rate, PIN diode X-ray detectors Iterative reconstruction with attenuation compensation from cone-beam projections acquired via non-planar orbit
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1