{"title":"气相色谱热导检测器:采集系统和实验测量","authors":"F. Rastrello, P. Placidi, A. Scorzoni, E. Cozzani, M. Messina, I. Elmi, S. Zampolli, G. Cardinali","doi":"10.1109/I2MTC.2012.6229304","DOIUrl":null,"url":null,"abstract":"The aim of this paper is to present an acquisition system and experimental measurements of a new micromachined Thermal Conductivity Detector (μTCD), applied downstream of a gas-chromatography (GC) system. We describe a simple and innovative electronics for sensor control and data acquisition, outlining its resistance control, native imbalance compensation and automatic gain control (AGC) algorithm. Measurements and sensitivity tests have been carried out by connecting our TCD and acquisition system downstream of the microfluidic section and GC column of a commercial GC system. Comparing the results with those of a complete commercial GC system we observed a similar response and noise. Sensitivity measurements on toluene masses gave very good results, having observed a sensitivity of 15.2±0.6 μVs/ng. This high sensitivity will enable the use of the μTCD in many portable applications like in-line quality control, industrial security and safety. We also show the good operation of the AGC algorithm.","PeriodicalId":387839,"journal":{"name":"2012 IEEE International Instrumentation and Measurement Technology Conference Proceedings","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2012-05-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Thermal Conductivity Detector for gas-chromatography: Acquisition system and experimental measurements\",\"authors\":\"F. Rastrello, P. Placidi, A. Scorzoni, E. Cozzani, M. Messina, I. Elmi, S. Zampolli, G. Cardinali\",\"doi\":\"10.1109/I2MTC.2012.6229304\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The aim of this paper is to present an acquisition system and experimental measurements of a new micromachined Thermal Conductivity Detector (μTCD), applied downstream of a gas-chromatography (GC) system. We describe a simple and innovative electronics for sensor control and data acquisition, outlining its resistance control, native imbalance compensation and automatic gain control (AGC) algorithm. Measurements and sensitivity tests have been carried out by connecting our TCD and acquisition system downstream of the microfluidic section and GC column of a commercial GC system. Comparing the results with those of a complete commercial GC system we observed a similar response and noise. Sensitivity measurements on toluene masses gave very good results, having observed a sensitivity of 15.2±0.6 μVs/ng. This high sensitivity will enable the use of the μTCD in many portable applications like in-line quality control, industrial security and safety. We also show the good operation of the AGC algorithm.\",\"PeriodicalId\":387839,\"journal\":{\"name\":\"2012 IEEE International Instrumentation and Measurement Technology Conference Proceedings\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-05-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 IEEE International Instrumentation and Measurement Technology Conference Proceedings\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/I2MTC.2012.6229304\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 IEEE International Instrumentation and Measurement Technology Conference Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/I2MTC.2012.6229304","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

本文的目的是介绍一种应用于气相色谱(GC)系统下游的新型微机械热导检测器(μTCD)的采集系统和实验测量。我们描述了一种简单而创新的传感器控制和数据采集电子设备,概述了其电阻控制,本机不平衡补偿和自动增益控制(AGC)算法。通过连接我们的TCD和采集系统下游的微流控切片和商业GC系统的气相色谱柱,进行了测量和灵敏度测试。将结果与完整的商用气相色谱系统进行比较,我们观察到相似的响应和噪声。对甲苯质量的灵敏度测量结果非常好,灵敏度为15.2±0.6 μVs/ng。这种高灵敏度将使μTCD在许多便携式应用中使用,如在线质量控制,工业安全和安全。我们还证明了AGC算法的良好运行。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Thermal Conductivity Detector for gas-chromatography: Acquisition system and experimental measurements
The aim of this paper is to present an acquisition system and experimental measurements of a new micromachined Thermal Conductivity Detector (μTCD), applied downstream of a gas-chromatography (GC) system. We describe a simple and innovative electronics for sensor control and data acquisition, outlining its resistance control, native imbalance compensation and automatic gain control (AGC) algorithm. Measurements and sensitivity tests have been carried out by connecting our TCD and acquisition system downstream of the microfluidic section and GC column of a commercial GC system. Comparing the results with those of a complete commercial GC system we observed a similar response and noise. Sensitivity measurements on toluene masses gave very good results, having observed a sensitivity of 15.2±0.6 μVs/ng. This high sensitivity will enable the use of the μTCD in many portable applications like in-line quality control, industrial security and safety. We also show the good operation of the AGC algorithm.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A hybrid multiple classifier system for recognizing usual and unusual drilling events Identification of time-varying systems using a two-dimensional B-spline algorithm Standard and customised measurements for wind potential assessment Position estimation using novel calibrated indoor positioning system Linear angle measurement using continuous wave ultrasonic oscillator
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1