{"title":"一种测量40 GHz非稳态电磁干扰的时域系统","authors":"C. Hoffmann, H. H. Slim, P. Russer","doi":"10.1109/APEMC.2012.6238008","DOIUrl":null,"url":null,"abstract":"In this paper, a time-domain measurement system for EMI measurements according to CISPR 16-1-1, MIL-461 and DO-160 in the frequency range from 10 Hz-40 GHz is presented. Signals with a frequency of up to 1.1 GHz are sampled by an ultra-fast floating-point analog-to-digital-converter (ADC), whereas signals from 1.1-40 GHz are first down-converted by an ultra-broadband multi-stage down-converter. With integrated preamplifiers, the system offers high sensitivity and maintains a low system noise floor of below 20 dBμV at 1 MHz IF-bandwidth up to 40 GHz. With a high system dynamic range of more than 70 dB, the system is well suited for the measurement of broadband, transient emissions. Non-stationary emissions can be measured via the real-time spectrogram or via the multi-channel amplitude probability distribution (APD) measuring method.","PeriodicalId":300639,"journal":{"name":"2012 Asia-Pacific Symposium on Electromagnetic Compatibility","volume":"26 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-05-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":"{\"title\":\"A time-domain system for the measurement of non-stationary EMI up to 40 GHz\",\"authors\":\"C. Hoffmann, H. H. Slim, P. Russer\",\"doi\":\"10.1109/APEMC.2012.6238008\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, a time-domain measurement system for EMI measurements according to CISPR 16-1-1, MIL-461 and DO-160 in the frequency range from 10 Hz-40 GHz is presented. Signals with a frequency of up to 1.1 GHz are sampled by an ultra-fast floating-point analog-to-digital-converter (ADC), whereas signals from 1.1-40 GHz are first down-converted by an ultra-broadband multi-stage down-converter. With integrated preamplifiers, the system offers high sensitivity and maintains a low system noise floor of below 20 dBμV at 1 MHz IF-bandwidth up to 40 GHz. With a high system dynamic range of more than 70 dB, the system is well suited for the measurement of broadband, transient emissions. Non-stationary emissions can be measured via the real-time spectrogram or via the multi-channel amplitude probability distribution (APD) measuring method.\",\"PeriodicalId\":300639,\"journal\":{\"name\":\"2012 Asia-Pacific Symposium on Electromagnetic Compatibility\",\"volume\":\"26 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-05-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 Asia-Pacific Symposium on Electromagnetic Compatibility\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APEMC.2012.6238008\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 Asia-Pacific Symposium on Electromagnetic Compatibility","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APEMC.2012.6238008","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A time-domain system for the measurement of non-stationary EMI up to 40 GHz
In this paper, a time-domain measurement system for EMI measurements according to CISPR 16-1-1, MIL-461 and DO-160 in the frequency range from 10 Hz-40 GHz is presented. Signals with a frequency of up to 1.1 GHz are sampled by an ultra-fast floating-point analog-to-digital-converter (ADC), whereas signals from 1.1-40 GHz are first down-converted by an ultra-broadband multi-stage down-converter. With integrated preamplifiers, the system offers high sensitivity and maintains a low system noise floor of below 20 dBμV at 1 MHz IF-bandwidth up to 40 GHz. With a high system dynamic range of more than 70 dB, the system is well suited for the measurement of broadband, transient emissions. Non-stationary emissions can be measured via the real-time spectrogram or via the multi-channel amplitude probability distribution (APD) measuring method.