Mahdi Srour, B. Potelon, C. Quendo, C. Person, J. Carré
{"title":"基于共振技术的生物传感器用于标准化医用试管水葡萄糖监测","authors":"Mahdi Srour, B. Potelon, C. Quendo, C. Person, J. Carré","doi":"10.1109/IMBIoC47321.2020.9385034","DOIUrl":null,"url":null,"abstract":"This paper presents a biosensor based on a resonant technique that quantifies the glucose concentration of a water/glucose mixture inserted into a standard medical test tube, which is located in the middle of a waveguide. The biosensor provides real-time data about the concentration of the solution under test by means of microwave non-invasive measurements. Interaction between electromagnetic fields and the dielectric solution to be measured (water/glucose mixture) results in a change of the S-parameters, which are observed in the 2.6 to 3.95 GHz range. The technique presented here could be further used for the monitoring of other liquids or aqueous solutions.","PeriodicalId":297049,"journal":{"name":"2020 IEEE MTT-S International Microwave Biomedical Conference (IMBioC)","volume":"11 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-12-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Biosensor Based on a Resonant Technique for Aqueous Glucose Monitoring Using Standardized Medical Test Tubes\",\"authors\":\"Mahdi Srour, B. Potelon, C. Quendo, C. Person, J. Carré\",\"doi\":\"10.1109/IMBIoC47321.2020.9385034\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a biosensor based on a resonant technique that quantifies the glucose concentration of a water/glucose mixture inserted into a standard medical test tube, which is located in the middle of a waveguide. The biosensor provides real-time data about the concentration of the solution under test by means of microwave non-invasive measurements. Interaction between electromagnetic fields and the dielectric solution to be measured (water/glucose mixture) results in a change of the S-parameters, which are observed in the 2.6 to 3.95 GHz range. The technique presented here could be further used for the monitoring of other liquids or aqueous solutions.\",\"PeriodicalId\":297049,\"journal\":{\"name\":\"2020 IEEE MTT-S International Microwave Biomedical Conference (IMBioC)\",\"volume\":\"11 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-12-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 IEEE MTT-S International Microwave Biomedical Conference (IMBioC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IMBIoC47321.2020.9385034\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE MTT-S International Microwave Biomedical Conference (IMBioC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IMBIoC47321.2020.9385034","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Biosensor Based on a Resonant Technique for Aqueous Glucose Monitoring Using Standardized Medical Test Tubes
This paper presents a biosensor based on a resonant technique that quantifies the glucose concentration of a water/glucose mixture inserted into a standard medical test tube, which is located in the middle of a waveguide. The biosensor provides real-time data about the concentration of the solution under test by means of microwave non-invasive measurements. Interaction between electromagnetic fields and the dielectric solution to be measured (water/glucose mixture) results in a change of the S-parameters, which are observed in the 2.6 to 3.95 GHz range. The technique presented here could be further used for the monitoring of other liquids or aqueous solutions.