Peng Wang, Yanghao Gu, Qi Wu, A. Cavallini, Qin Zhang, Jiawei Zhang
{"title":"环境湿度对逆变电机绝缘PDIV和寿命的影响","authors":"Peng Wang, Yanghao Gu, Qi Wu, A. Cavallini, Qin Zhang, Jiawei Zhang","doi":"10.1109/EIC43217.2019.9046593","DOIUrl":null,"url":null,"abstract":"This work aims to report the influence of ambient humidity on partial discharge inception voltage (PDIV) and lifetime (endurance) of the insulation for inverter-fed motors. The PDIV on polyimide film and rotor bar insulated by NOMEX at sinusoidal voltages with 50 Hz frequency and the endurance tests of inverter-fed motor turn insulation under repetitive unipolar impulsive voltages with 10 ns rise time and 200 ns voltage on-time were performed at four relative humidity (RH), i.e. 40%, 60%, 80%, 95%, controlling the ambient temperature at 50 °C. Experimental results show that both the PDIV and endurance decrease significantly with increasing RH. Accordingly, the influence of ambient humidity on the test results should be carefully considered when performing PDIV and endurance tests on the insulation of low-voltage and high-voltage inverter-fed motors according to IEC standards.","PeriodicalId":340602,"journal":{"name":"2019 IEEE Electrical Insulation Conference (EIC)","volume":"135 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Influence of Ambient Humidity on PDIV and Endurance of Inverter-fed Motor Insulation\",\"authors\":\"Peng Wang, Yanghao Gu, Qi Wu, A. Cavallini, Qin Zhang, Jiawei Zhang\",\"doi\":\"10.1109/EIC43217.2019.9046593\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This work aims to report the influence of ambient humidity on partial discharge inception voltage (PDIV) and lifetime (endurance) of the insulation for inverter-fed motors. The PDIV on polyimide film and rotor bar insulated by NOMEX at sinusoidal voltages with 50 Hz frequency and the endurance tests of inverter-fed motor turn insulation under repetitive unipolar impulsive voltages with 10 ns rise time and 200 ns voltage on-time were performed at four relative humidity (RH), i.e. 40%, 60%, 80%, 95%, controlling the ambient temperature at 50 °C. Experimental results show that both the PDIV and endurance decrease significantly with increasing RH. Accordingly, the influence of ambient humidity on the test results should be carefully considered when performing PDIV and endurance tests on the insulation of low-voltage and high-voltage inverter-fed motors according to IEC standards.\",\"PeriodicalId\":340602,\"journal\":{\"name\":\"2019 IEEE Electrical Insulation Conference (EIC)\",\"volume\":\"135 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 IEEE Electrical Insulation Conference (EIC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EIC43217.2019.9046593\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE Electrical Insulation Conference (EIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EIC43217.2019.9046593","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

本研究旨在报告环境湿度对逆变电机局部放电起始电压(PDIV)和绝缘寿命(耐久性)的影响。在相对湿度为40%、60%、80%、95%的4种相对湿度(RH)条件下,控制环境温度为50℃,在频率为50 Hz的正弦电压下,对NOMEX绝缘的聚酰亚胺薄膜和转子棒进行PDIV和逆变电机匝绝缘在10 ns上升时间和200 ns导通时间的重复单极脉冲电压下的耐久性试验。实验结果表明,随着相对湿度的增加,PDIV和耐久度均显著降低。因此,在按IEC标准对低压和高压变频电机绝缘进行PDIV和耐久性试验时,应认真考虑环境湿度对试验结果的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Influence of Ambient Humidity on PDIV and Endurance of Inverter-fed Motor Insulation
This work aims to report the influence of ambient humidity on partial discharge inception voltage (PDIV) and lifetime (endurance) of the insulation for inverter-fed motors. The PDIV on polyimide film and rotor bar insulated by NOMEX at sinusoidal voltages with 50 Hz frequency and the endurance tests of inverter-fed motor turn insulation under repetitive unipolar impulsive voltages with 10 ns rise time and 200 ns voltage on-time were performed at four relative humidity (RH), i.e. 40%, 60%, 80%, 95%, controlling the ambient temperature at 50 °C. Experimental results show that both the PDIV and endurance decrease significantly with increasing RH. Accordingly, the influence of ambient humidity on the test results should be carefully considered when performing PDIV and endurance tests on the insulation of low-voltage and high-voltage inverter-fed motors according to IEC standards.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Diagnostic Testing of Power Cable Insulation For Reliable Smart Grid Operation Investigation of the Thickness Effect on DC Breakdown Strength for HVDC Flexible Cable Insulation Associated with Space Charge Classification of Insulating Liquids Thermal Treatment Using Infrared Spectroscopy and Multivariate Statistical Method Study on the Ageing Characteristics of Persea Americana Oil as an Alternative Transformer Insulation oil Evaluation of Nano-Composite XLPE Compound on Accelerated Aging Cable Performance
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1