重力水涡电厂开合缸排水管理

M. H. Basri, Ainun Nasuki
{"title":"重力水涡电厂开合缸排水管理","authors":"M. H. Basri, Ainun Nasuki","doi":"10.21070/jeeeu.v5i1.1008","DOIUrl":null,"url":null,"abstract":"A Gravitation Water Vortex Power Plant (GWVPP) tool has been made to determine how much water flow is needed to generate electricity. This research was conducted by changing the flow rate and water pressure to determine the effect on the performance of a vortex power plant, and in previous studies, no one has made changes to the discharge and water pressure. The type of basin position used in this study is an open basin position and a closed basin position. Based on the advantages and disadvantages of each type of blade used, a study was carried out using the type of turbine blade model L by changing the water flow rate and water pressure at a predetermined position to determine the effect of water discharge and pressure on the turbine rotational speed. From the results of testing the water discharge measurement in a closed basin which is carried out on the addition of each flow of water discharge at the angle of the faucet 0o to 90o with a volume (V) 98 L and time (t) 1.11 minutes to 2.5 minutes, it can be seen that the average discharge value (Q) the resulting 81.08 l / s. and from the results of testing the water discharge measurement in the open basin which is carried out to the addition of each flow of water discharge at the angle of the faucet 0o to 90o with a volume (V) 98 L and time (t) 1.28 minutes to 4.1 minutes it can be seen that the average discharge value (Q ) resulting in 65.21 l / s.","PeriodicalId":320287,"journal":{"name":"JEEE-U (Journal of Electrical and Electronic Engineering-UMSIDA)","volume":"21 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-03-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Water Discharge Management Based on Open and Closed Cylinders in the Gravitation Water Vortex Power Plant\",\"authors\":\"M. H. Basri, Ainun Nasuki\",\"doi\":\"10.21070/jeeeu.v5i1.1008\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A Gravitation Water Vortex Power Plant (GWVPP) tool has been made to determine how much water flow is needed to generate electricity. This research was conducted by changing the flow rate and water pressure to determine the effect on the performance of a vortex power plant, and in previous studies, no one has made changes to the discharge and water pressure. The type of basin position used in this study is an open basin position and a closed basin position. Based on the advantages and disadvantages of each type of blade used, a study was carried out using the type of turbine blade model L by changing the water flow rate and water pressure at a predetermined position to determine the effect of water discharge and pressure on the turbine rotational speed. From the results of testing the water discharge measurement in a closed basin which is carried out on the addition of each flow of water discharge at the angle of the faucet 0o to 90o with a volume (V) 98 L and time (t) 1.11 minutes to 2.5 minutes, it can be seen that the average discharge value (Q) the resulting 81.08 l / s. and from the results of testing the water discharge measurement in the open basin which is carried out to the addition of each flow of water discharge at the angle of the faucet 0o to 90o with a volume (V) 98 L and time (t) 1.28 minutes to 4.1 minutes it can be seen that the average discharge value (Q ) resulting in 65.21 l / s.\",\"PeriodicalId\":320287,\"journal\":{\"name\":\"JEEE-U (Journal of Electrical and Electronic Engineering-UMSIDA)\",\"volume\":\"21 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-03-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"JEEE-U (Journal of Electrical and Electronic Engineering-UMSIDA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.21070/jeeeu.v5i1.1008\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"JEEE-U (Journal of Electrical and Electronic Engineering-UMSIDA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21070/jeeeu.v5i1.1008","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

一个重力水涡发电厂(GWVPP)工具被用来确定发电需要多少水流量。本研究是通过改变流量和水压来确定对涡电厂性能的影响,在以往的研究中,没有人改变流量和水压。本研究采用的盆位类型为开盆位和闭盆位。在分析各类型叶片优缺点的基础上,采用L型涡轮叶片进行研究,在预定位置改变水流流量和水压,确定放水量和压力对涡轮转速的影响。从封闭水盆排水测量的测试结果来看,该测试是在水龙头的角度为0 ~ 90°,体积(V)为98 L,时间(t)为1.11 ~ 2.5分钟,每一流量的排水加在一起进行的。可以看出,平均放电值(Q)产生的81.08 l / s,从测试的结果排水测量在开阔的盆地进行的每个流排水的水龙头的角度0到90 o体积(V) 98 l和时间(t) 1.28分钟4.1分钟可以看出平均放电值(Q)导致65.21 l / s。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Water Discharge Management Based on Open and Closed Cylinders in the Gravitation Water Vortex Power Plant
A Gravitation Water Vortex Power Plant (GWVPP) tool has been made to determine how much water flow is needed to generate electricity. This research was conducted by changing the flow rate and water pressure to determine the effect on the performance of a vortex power plant, and in previous studies, no one has made changes to the discharge and water pressure. The type of basin position used in this study is an open basin position and a closed basin position. Based on the advantages and disadvantages of each type of blade used, a study was carried out using the type of turbine blade model L by changing the water flow rate and water pressure at a predetermined position to determine the effect of water discharge and pressure on the turbine rotational speed. From the results of testing the water discharge measurement in a closed basin which is carried out on the addition of each flow of water discharge at the angle of the faucet 0o to 90o with a volume (V) 98 L and time (t) 1.11 minutes to 2.5 minutes, it can be seen that the average discharge value (Q) the resulting 81.08 l / s. and from the results of testing the water discharge measurement in the open basin which is carried out to the addition of each flow of water discharge at the angle of the faucet 0o to 90o with a volume (V) 98 L and time (t) 1.28 minutes to 4.1 minutes it can be seen that the average discharge value (Q ) resulting in 65.21 l / s.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Leak Monitoring in Split Duct Air Conditioner Based on Internet of Things Design of a Height and Weight Measurement Tool for Toddlers at Spreadsheet-Based Posyandu The Protection Relay Coordination Studies (Over Current Relays and Ground Fault Relays) On The Power Plant Electrical System, PT. Rekind Daya Mamuju By Using The ETAP 12.6 Program Design of Atmega2560 Charge Controller Battery Using Static Bicycle Sistem Monitoring Dan Kontrol Motor Listrik Industri Menggunakan Internet Of Things (IoT)
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1