高压设备中脉冲补偿电流检测的在线PD测量

Chissanupong Srinangyam, P. Pannil, P. Nimsanong, C. Chuayin, K. Thungsook, N. Pattanadech
{"title":"高压设备中脉冲补偿电流检测的在线PD测量","authors":"Chissanupong Srinangyam, P. Pannil, P. Nimsanong, C. Chuayin, K. Thungsook, N. Pattanadech","doi":"10.1109/iceast55249.2022.9826301","DOIUrl":null,"url":null,"abstract":"This paper discusses the pulsed compensating current caused by partial discharge (PD) phenomena that flows inside the electrical equipment installed in the power system. Such electrical equipment like to be the capacitive coupler in the partial discharge test circuit. In order to study the pulsed compensating current of the PD measurement, artificial PD source such as corona, surface, and internal was used in this experiment. The electrical equipment like surge arrester combined with HFCT sensor utilized to detect the PD pulse current. Furthermore, this proposed technique has been applied for online PD measurement in substations. It was found that the surge arrester could compensate for the pulse current arising from the PD source. This study will be helpful information for online PD measurement.","PeriodicalId":441430,"journal":{"name":"2022 8th International Conference on Engineering, Applied Sciences, and Technology (ICEAST)","volume":"34 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-06-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Online PD Measurement by Detecting the Pulsed Compensating Current in High Voltage Equipment\",\"authors\":\"Chissanupong Srinangyam, P. Pannil, P. Nimsanong, C. Chuayin, K. Thungsook, N. Pattanadech\",\"doi\":\"10.1109/iceast55249.2022.9826301\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper discusses the pulsed compensating current caused by partial discharge (PD) phenomena that flows inside the electrical equipment installed in the power system. Such electrical equipment like to be the capacitive coupler in the partial discharge test circuit. In order to study the pulsed compensating current of the PD measurement, artificial PD source such as corona, surface, and internal was used in this experiment. The electrical equipment like surge arrester combined with HFCT sensor utilized to detect the PD pulse current. Furthermore, this proposed technique has been applied for online PD measurement in substations. It was found that the surge arrester could compensate for the pulse current arising from the PD source. This study will be helpful information for online PD measurement.\",\"PeriodicalId\":441430,\"journal\":{\"name\":\"2022 8th International Conference on Engineering, Applied Sciences, and Technology (ICEAST)\",\"volume\":\"34 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-06-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 8th International Conference on Engineering, Applied Sciences, and Technology (ICEAST)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/iceast55249.2022.9826301\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 8th International Conference on Engineering, Applied Sciences, and Technology (ICEAST)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/iceast55249.2022.9826301","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文讨论了电力系统中电气设备内部由于局部放电现象而产生的脉冲补偿电流。在局部放电试验电路中,这种电气设备通常用作容性耦合器。为了研究局部放电测量的脉冲补偿电流,本实验采用了电晕源、表面源和内部源等人工局部放电源。利用避雷器等电气设备与HFCT传感器相结合来检测PD脉冲电流。并将该方法应用于变电站的在线PD测量中。结果表明,该避雷器可以补偿PD源产生的脉冲电流。本研究将为在线PD测量提供有益的信息。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Online PD Measurement by Detecting the Pulsed Compensating Current in High Voltage Equipment
This paper discusses the pulsed compensating current caused by partial discharge (PD) phenomena that flows inside the electrical equipment installed in the power system. Such electrical equipment like to be the capacitive coupler in the partial discharge test circuit. In order to study the pulsed compensating current of the PD measurement, artificial PD source such as corona, surface, and internal was used in this experiment. The electrical equipment like surge arrester combined with HFCT sensor utilized to detect the PD pulse current. Furthermore, this proposed technique has been applied for online PD measurement in substations. It was found that the surge arrester could compensate for the pulse current arising from the PD source. This study will be helpful information for online PD measurement.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Investigation of Wireless Body Area Network Localization Based on Measurement Data The Misconception of Relational Database and the ACID Properties The Bandwidth Verification of on-site UHF Sensor for Partial Discharge Measurement Online PD Measurement by Detecting the Pulsed Compensating Current in High Voltage Equipment Measuring System for Parameter Evaluation of Full Lightning Impulse Voltage Waveform
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1