M. Hazumi, T. Kawasaki, K. Senyo, Y. Nagashima, K. Yamamoto, K. Yamamura, T. Tsuboyama, J. Haba, H. Ikeda, H. Iwasaki, T. Matsuda, H. Ozaki, M. Tanaka, Y. Yamada, S. Okuno, S. Avrillon, Y. Asano, S. Mori, C. Fukunaga, T. Hirose, H. Miyata, K. Miyano, E. Banas, A. Bozek, Z. Natkaniec, H. Palka, M. Różańska, K. Rybicki
{"title":"大读出节距硅微带探测器的评价","authors":"M. Hazumi, T. Kawasaki, K. Senyo, Y. Nagashima, K. Yamamoto, K. Yamamura, T. Tsuboyama, J. Haba, H. Ikeda, H. Iwasaki, T. Matsuda, H. Ozaki, M. Tanaka, Y. Yamada, S. Okuno, S. Avrillon, Y. Asano, S. Mori, C. Fukunaga, T. Hirose, H. Miyata, K. Miyano, E. Banas, A. Bozek, Z. Natkaniec, H. Palka, M. Różańska, K. Rybicki","doi":"10.1109/NSSMIC.1995.504279","DOIUrl":null,"url":null,"abstract":"For the development of the silicon micro strip detector with the pitch of the readout strips as large as 250 /spl mu/m on ohmic side, we made samples with different structures. Charge collection was evaluated to optimize the width of implant strips, aluminum read-out strips, and/or the read-out scheme among strips.","PeriodicalId":409998,"journal":{"name":"1995 IEEE Nuclear Science Symposium and Medical Imaging Conference Record","volume":"52 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1995-10-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Evaluation of silicon micro strip detectors with large read-out pitch\",\"authors\":\"M. Hazumi, T. Kawasaki, K. Senyo, Y. Nagashima, K. Yamamoto, K. Yamamura, T. Tsuboyama, J. Haba, H. Ikeda, H. Iwasaki, T. Matsuda, H. Ozaki, M. Tanaka, Y. Yamada, S. Okuno, S. Avrillon, Y. Asano, S. Mori, C. Fukunaga, T. Hirose, H. Miyata, K. Miyano, E. Banas, A. Bozek, Z. Natkaniec, H. Palka, M. Różańska, K. Rybicki\",\"doi\":\"10.1109/NSSMIC.1995.504279\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"For the development of the silicon micro strip detector with the pitch of the readout strips as large as 250 /spl mu/m on ohmic side, we made samples with different structures. Charge collection was evaluated to optimize the width of implant strips, aluminum read-out strips, and/or the read-out scheme among strips.\",\"PeriodicalId\":409998,\"journal\":{\"name\":\"1995 IEEE Nuclear Science Symposium and Medical Imaging Conference Record\",\"volume\":\"52 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1995-10-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1995 IEEE Nuclear Science Symposium and Medical Imaging Conference Record\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSSMIC.1995.504279\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1995 IEEE Nuclear Science Symposium and Medical Imaging Conference Record","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.1995.504279","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Evaluation of silicon micro strip detectors with large read-out pitch
For the development of the silicon micro strip detector with the pitch of the readout strips as large as 250 /spl mu/m on ohmic side, we made samples with different structures. Charge collection was evaluated to optimize the width of implant strips, aluminum read-out strips, and/or the read-out scheme among strips.