{"title":"应力分级绝缘子悬架绝缘子的防污染设计研究","authors":"M. Akizuki, O. Fujii, S. Ito, T. Irie, S. Nishimura","doi":"10.1109/PESS.2002.1043238","DOIUrl":null,"url":null,"abstract":"Insulator contamination is one of many serious problems for power systems. Outages due to insulator contamination flashover may affect a wide area and continue for a long time. Also, the corona noise causes radio and TV interference. Therefore, efforts have been made by many around the world to prevent such phenomena. Presently, fog type and semi-conducting glaze insulators have been developed, and successfully used. However, the former cannot suppress the corona and the latter has a subject to study from the viewpoint of thermal stability in heavy contamination conditions. A new concept insulator, with a stress graded zone on the bottom surface, has been studied. It has been determined that a dry band is not formed on this stress graded zone and a long dry band is formed at the first rib. This means the insulator has a high discharge starting voltage and high contamination withstand voltage.","PeriodicalId":117177,"journal":{"name":"IEEE Power Engineering Society Summer Meeting,","volume":"203 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-07-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"A study on anti-contamination design of suspension insulators-a stress grading insulator\",\"authors\":\"M. Akizuki, O. Fujii, S. Ito, T. Irie, S. Nishimura\",\"doi\":\"10.1109/PESS.2002.1043238\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Insulator contamination is one of many serious problems for power systems. Outages due to insulator contamination flashover may affect a wide area and continue for a long time. Also, the corona noise causes radio and TV interference. Therefore, efforts have been made by many around the world to prevent such phenomena. Presently, fog type and semi-conducting glaze insulators have been developed, and successfully used. However, the former cannot suppress the corona and the latter has a subject to study from the viewpoint of thermal stability in heavy contamination conditions. A new concept insulator, with a stress graded zone on the bottom surface, has been studied. It has been determined that a dry band is not formed on this stress graded zone and a long dry band is formed at the first rib. This means the insulator has a high discharge starting voltage and high contamination withstand voltage.\",\"PeriodicalId\":117177,\"journal\":{\"name\":\"IEEE Power Engineering Society Summer Meeting,\",\"volume\":\"203 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-07-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Power Engineering Society Summer Meeting,\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PESS.2002.1043238\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Power Engineering Society Summer Meeting,","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESS.2002.1043238","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

绝缘子污染是电力系统面临的严重问题之一。由于绝缘子污染闪络引起的停电可能会影响广泛的区域并持续很长时间。此外,日冕噪声还会对无线电和电视造成干扰。因此,世界上许多国家都在努力防止这种现象的发生。目前已经研制出雾型和半导釉绝缘子,并取得了成功的应用。然而,前者不能抑制日冕,而后者则需要从重污染条件下的热稳定性角度进行研究。本文研究了一种新的概念绝缘子,它的底表面有一个应力梯度区。在此应力梯度区不形成干带,在第一肋处形成长干带。这意味着绝缘子具有高放电启动电压和高耐污染电压。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A study on anti-contamination design of suspension insulators-a stress grading insulator
Insulator contamination is one of many serious problems for power systems. Outages due to insulator contamination flashover may affect a wide area and continue for a long time. Also, the corona noise causes radio and TV interference. Therefore, efforts have been made by many around the world to prevent such phenomena. Presently, fog type and semi-conducting glaze insulators have been developed, and successfully used. However, the former cannot suppress the corona and the latter has a subject to study from the viewpoint of thermal stability in heavy contamination conditions. A new concept insulator, with a stress graded zone on the bottom surface, has been studied. It has been determined that a dry band is not formed on this stress graded zone and a long dry band is formed at the first rib. This means the insulator has a high discharge starting voltage and high contamination withstand voltage.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
New algorithm to phase selection based on wavelet transforms A parameter identification technique for metal-oxide surge arrester models Dynamic security enhancement in power-market systems Evaluation of currents and charges in low-voltage surge arresters due to lightning strikes Local area spatial load forecasting at NSTAR
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1