{"title":"在罕见事件搜索实验中使用一种新型主动否决权探测器减少放射性诱导背景","authors":"Mouli Chaudhuri, A. Jastram, G. Agnolet, S. Banik, Hao Chen, V. Iyer, V. Kashyap, A. Kubik, Matthew Lee, R. Mahapatra, S. Maludze, N. Mirabolfathi, Nityasa Mishra, B. Mohanty, H. Neog, Mark Platt","doi":"10.21468/scipostphysproc.12.017","DOIUrl":null,"url":null,"abstract":"The results of a newly developed annular cryogenic phonon-mediated active veto detector are discussed which shows a significant reduction of radioactivity-induced backgrounds in rare event search experiments. The veto detector is made up of germanium weighing ∼500 g with an outer diameter of 76 mm and an inner diameter of 28 mm. The detector can host a 25 mm diameter germanium inner target detector of mass ∼10 g. A GEANT4 simulation with the active veto and inner target detector shows a gamma background reduction of 50 - 80% which is further improved (> 90%) with 4pi veto coverage. Experimental measurements with the detector assembly agree well with the simulation.","PeriodicalId":355998,"journal":{"name":"SciPost Physics Proceedings","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-07-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Reduction in radioactivity-induced backgrounds using a novel active veto detector for rare event search experiments\",\"authors\":\"Mouli Chaudhuri, A. Jastram, G. Agnolet, S. Banik, Hao Chen, V. Iyer, V. Kashyap, A. Kubik, Matthew Lee, R. Mahapatra, S. Maludze, N. Mirabolfathi, Nityasa Mishra, B. Mohanty, H. Neog, Mark Platt\",\"doi\":\"10.21468/scipostphysproc.12.017\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The results of a newly developed annular cryogenic phonon-mediated active veto detector are discussed which shows a significant reduction of radioactivity-induced backgrounds in rare event search experiments. The veto detector is made up of germanium weighing ∼500 g with an outer diameter of 76 mm and an inner diameter of 28 mm. The detector can host a 25 mm diameter germanium inner target detector of mass ∼10 g. A GEANT4 simulation with the active veto and inner target detector shows a gamma background reduction of 50 - 80% which is further improved (> 90%) with 4pi veto coverage. Experimental measurements with the detector assembly agree well with the simulation.\",\"PeriodicalId\":355998,\"journal\":{\"name\":\"SciPost Physics Proceedings\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-07-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"SciPost Physics Proceedings\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.21468/scipostphysproc.12.017\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"SciPost Physics Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21468/scipostphysproc.12.017","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

讨论了新开发的环形低温声子介导的主动否决权探测器的结果,该探测器在罕见事件搜索实验中显着减少了放射性诱导背景。该探测器由重约500克的锗制成,外径76毫米,内径28毫米。该探测器可以容纳一个直径为25毫米、质量为10克的锗内部目标探测器。GEANT4模拟显示,主动否决和内部目标检测器的伽马背景降低了50 - 80%,在4pi否决覆盖率下进一步提高(> 90%)。实验测量结果与仿真结果吻合较好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Reduction in radioactivity-induced backgrounds using a novel active veto detector for rare event search experiments
The results of a newly developed annular cryogenic phonon-mediated active veto detector are discussed which shows a significant reduction of radioactivity-induced backgrounds in rare event search experiments. The veto detector is made up of germanium weighing ∼500 g with an outer diameter of 76 mm and an inner diameter of 28 mm. The detector can host a 25 mm diameter germanium inner target detector of mass ∼10 g. A GEANT4 simulation with the active veto and inner target detector shows a gamma background reduction of 50 - 80% which is further improved (> 90%) with 4pi veto coverage. Experimental measurements with the detector assembly agree well with the simulation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Implications of exclusive J/$\psi$ photoproduction in a tamed collinear factorisation approach to NLO Intermittency analysis of charged hadrons generated in Pb-Pb collisions at $\sqrt{s_{NN}}$= 2.76 TeV and 5.02 TeV Vinberg's T-algebras: From exceptional periodicity to black hole entropy The parastatistics of braided Majorana fermions On Möbius gyrogroup and Möbius gyrovector space
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1