{"title":"一种计算直流接触器剩余磁通的新方法","authors":"Baiqiang Li, Shaohua Ma, Z. Cai, Yahong Zheng","doi":"10.1109/ICEPE-ST.2019.8928892","DOIUrl":null,"url":null,"abstract":"Reliable calculation model of electromagnetic mechanism characteristics of DC contactor is of great significance to its structural optimization. In this paper, the excitation process of contactor magnet is summarized, and a new calculation model of hysteresis-finite element method is proposed. It can effectively calculate the remanence of the electromagnetic mechanism under different excitation conditions, and give the relationship curve between the remanence flux and the anti-remanence gap.","PeriodicalId":392306,"journal":{"name":"2019 5th International Conference on Electric Power Equipment - Switching Technology (ICEPE-ST)","volume":"36 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Novel Method for Calculating Residual Magnetic Flux of DC Contactors\",\"authors\":\"Baiqiang Li, Shaohua Ma, Z. Cai, Yahong Zheng\",\"doi\":\"10.1109/ICEPE-ST.2019.8928892\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Reliable calculation model of electromagnetic mechanism characteristics of DC contactor is of great significance to its structural optimization. In this paper, the excitation process of contactor magnet is summarized, and a new calculation model of hysteresis-finite element method is proposed. It can effectively calculate the remanence of the electromagnetic mechanism under different excitation conditions, and give the relationship curve between the remanence flux and the anti-remanence gap.\",\"PeriodicalId\":392306,\"journal\":{\"name\":\"2019 5th International Conference on Electric Power Equipment - Switching Technology (ICEPE-ST)\",\"volume\":\"36 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 5th International Conference on Electric Power Equipment - Switching Technology (ICEPE-ST)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICEPE-ST.2019.8928892\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 5th International Conference on Electric Power Equipment - Switching Technology (ICEPE-ST)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEPE-ST.2019.8928892","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A Novel Method for Calculating Residual Magnetic Flux of DC Contactors
Reliable calculation model of electromagnetic mechanism characteristics of DC contactor is of great significance to its structural optimization. In this paper, the excitation process of contactor magnet is summarized, and a new calculation model of hysteresis-finite element method is proposed. It can effectively calculate the remanence of the electromagnetic mechanism under different excitation conditions, and give the relationship curve between the remanence flux and the anti-remanence gap.