Huang Ling, W. Jianguo, Dong Wansheng, Chen Cixuan
{"title":"基于传感器全方程的瞬态磁场波形数字重建","authors":"Huang Ling, W. Jianguo, Dong Wansheng, Chen Cixuan","doi":"10.1109/ICSMC2.2003.1428241","DOIUrl":null,"url":null,"abstract":"This paper deduces a kind of simple method based on the sensor's full electromagnetic induction equation to reconstruct the transient magnetic field waveform in time domain. Research on the external electromagnetic interference source, background noise of oscilloscope and calibration method has been conducted in detail. Different kinds of methods to reduce interference and measurement error through the software and hardware method have been tested successfully. Calibration was conducted with impulse current generator from mus to ms scale. The results show that the reconstructed waveform is very consistent with the source waveform either in low frequency or in high frequency with less than 5% magnitude error","PeriodicalId":272545,"journal":{"name":"2003 IEEE International Symposium on Electromagnetic Compatibility, 2003. EMC '03.","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Transient magnetic field waveform digital reconstruction based on sensor's full equation\",\"authors\":\"Huang Ling, W. Jianguo, Dong Wansheng, Chen Cixuan\",\"doi\":\"10.1109/ICSMC2.2003.1428241\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper deduces a kind of simple method based on the sensor's full electromagnetic induction equation to reconstruct the transient magnetic field waveform in time domain. Research on the external electromagnetic interference source, background noise of oscilloscope and calibration method has been conducted in detail. Different kinds of methods to reduce interference and measurement error through the software and hardware method have been tested successfully. Calibration was conducted with impulse current generator from mus to ms scale. The results show that the reconstructed waveform is very consistent with the source waveform either in low frequency or in high frequency with less than 5% magnitude error\",\"PeriodicalId\":272545,\"journal\":{\"name\":\"2003 IEEE International Symposium on Electromagnetic Compatibility, 2003. EMC '03.\",\"volume\":\"17 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-05-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2003 IEEE International Symposium on Electromagnetic Compatibility, 2003. EMC '03.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSMC2.2003.1428241\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2003 IEEE International Symposium on Electromagnetic Compatibility, 2003. EMC '03.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSMC2.2003.1428241","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Transient magnetic field waveform digital reconstruction based on sensor's full equation
This paper deduces a kind of simple method based on the sensor's full electromagnetic induction equation to reconstruct the transient magnetic field waveform in time domain. Research on the external electromagnetic interference source, background noise of oscilloscope and calibration method has been conducted in detail. Different kinds of methods to reduce interference and measurement error through the software and hardware method have been tested successfully. Calibration was conducted with impulse current generator from mus to ms scale. The results show that the reconstructed waveform is very consistent with the source waveform either in low frequency or in high frequency with less than 5% magnitude error