考虑电磁环和局部调节效应的动态等效网格化简方法

Yuqiang Hou, Yongiie Fang, Fusuo Liu, Jianbing Xu, Wei Li
{"title":"考虑电磁环和局部调节效应的动态等效网格化简方法","authors":"Yuqiang Hou, Yongiie Fang, Fusuo Liu, Jianbing Xu, Wei Li","doi":"10.1109/POWERCON.2018.8601730","DOIUrl":null,"url":null,"abstract":"Keeping the invariability of power flow and dynamic characteristics of generators rotor angles before and after the equivalent is an essential evaluation indicator for dynamic equivalence, which is necessary to electromagnetic transient modeling and simulation. A novel dynamic equivalent method is proposed for large-scale power systems electromagnetic transient modeling, which could reflect the characteristics of power alternation via electromagnetic loop and local accommodation among generators and loads in the equivalent network. The key method is to determine an equivalent bus for each node located in the equivalent section firstly, calculate the equivalent bus voltage(magnitude and phase) as well as the impedance of the equivalent tie branch follow the principle of unchanged of power flow and total current of the boundary transmission sections based on the initial operation point of the original power grids, then compute the effective sending power ability of equivalent coherent generators, and the effective receiving power ability for each equivalent bus. The effective load is summed finally for every equivalent bus. The real power system cases equivalent results demonstrate the accuracy and effectiveness of the method.","PeriodicalId":260947,"journal":{"name":"2018 International Conference on Power System Technology (POWERCON)","volume":"220 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Grid Reduction Method Considering Electromagnetic Loop and Local Accommodation Effect for the Dynamic Equivalent\",\"authors\":\"Yuqiang Hou, Yongiie Fang, Fusuo Liu, Jianbing Xu, Wei Li\",\"doi\":\"10.1109/POWERCON.2018.8601730\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Keeping the invariability of power flow and dynamic characteristics of generators rotor angles before and after the equivalent is an essential evaluation indicator for dynamic equivalence, which is necessary to electromagnetic transient modeling and simulation. A novel dynamic equivalent method is proposed for large-scale power systems electromagnetic transient modeling, which could reflect the characteristics of power alternation via electromagnetic loop and local accommodation among generators and loads in the equivalent network. The key method is to determine an equivalent bus for each node located in the equivalent section firstly, calculate the equivalent bus voltage(magnitude and phase) as well as the impedance of the equivalent tie branch follow the principle of unchanged of power flow and total current of the boundary transmission sections based on the initial operation point of the original power grids, then compute the effective sending power ability of equivalent coherent generators, and the effective receiving power ability for each equivalent bus. The effective load is summed finally for every equivalent bus. The real power system cases equivalent results demonstrate the accuracy and effectiveness of the method.\",\"PeriodicalId\":260947,\"journal\":{\"name\":\"2018 International Conference on Power System Technology (POWERCON)\",\"volume\":\"220 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 International Conference on Power System Technology (POWERCON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/POWERCON.2018.8601730\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 International Conference on Power System Technology (POWERCON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/POWERCON.2018.8601730","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

保持等效前后潮流的不变性和发电机转子角度的动态特性是动态等效的重要评价指标,是电磁暂态建模与仿真的必要条件。提出了一种新的大型电力系统电磁暂态建模的动态等效方法,该方法可以通过电磁回路和等效网络中发电机和负荷之间的局部调节来反映电力交替特性。其关键方法是首先为位于等效区段内的每个节点确定一条等效母线,根据原电网的初始工作点,按照边界传输区段潮流和总电流不变的原则,计算等效母线电压(幅值和相位)以及等效支路阻抗,然后计算等效相干发电机的有效发功率能力。以及各等效母线的有效接收功率能力。最后对每个等效母线的有效载荷求和。实际电力系统算例的等效结果验证了该方法的准确性和有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Grid Reduction Method Considering Electromagnetic Loop and Local Accommodation Effect for the Dynamic Equivalent
Keeping the invariability of power flow and dynamic characteristics of generators rotor angles before and after the equivalent is an essential evaluation indicator for dynamic equivalence, which is necessary to electromagnetic transient modeling and simulation. A novel dynamic equivalent method is proposed for large-scale power systems electromagnetic transient modeling, which could reflect the characteristics of power alternation via electromagnetic loop and local accommodation among generators and loads in the equivalent network. The key method is to determine an equivalent bus for each node located in the equivalent section firstly, calculate the equivalent bus voltage(magnitude and phase) as well as the impedance of the equivalent tie branch follow the principle of unchanged of power flow and total current of the boundary transmission sections based on the initial operation point of the original power grids, then compute the effective sending power ability of equivalent coherent generators, and the effective receiving power ability for each equivalent bus. The effective load is summed finally for every equivalent bus. The real power system cases equivalent results demonstrate the accuracy and effectiveness of the method.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Consistency of damping torque and energy flow dissipation coefficient in oscillation stability analysis Optimization of grid-related protection setting for thermal power units in regional power grid including new energy Research on Analytic Method of Power System Frequency Response Characteristics under Large Power Disturbance A Transmission System Planning Method Considering Fuzzy Model of Load and Interval Model of Renewable Power Analysis of the Impact of Trading Pattern on PV Plant Investment in Spot Market
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1