{"title":"用于高密度可穿戴生物电位传感器网络的非接触式低功率EEG/ECG电极","authors":"Y. Chi, S. Deiss, G. Cauwenberghs","doi":"10.1109/BSN.2009.52","DOIUrl":null,"url":null,"abstract":"A non-contact capacitive biopotential electrode with a common-mode noise suppression circuit is presented. The sensor network utilizes a single conductive sheet to establish a common body wide reference line, eliminating the need for an explicit signal ground connection. Each electrode senses the local biopotential with a differential gain of 46dB over a 1-100Hz bandwidth. Signals are digitized directly on board with a 16-bit ADC. The coin sized electrode consumes 285uA from a single 3.3V supply, and interfaces with a serial data bus for daisy-chain integration in body area sensor networks.","PeriodicalId":269861,"journal":{"name":"2009 Sixth International Workshop on Wearable and Implantable Body Sensor Networks","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2009-06-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"109","resultStr":"{\"title\":\"Non-contact Low Power EEG/ECG Electrode for High Density Wearable Biopotential Sensor Networks\",\"authors\":\"Y. Chi, S. Deiss, G. Cauwenberghs\",\"doi\":\"10.1109/BSN.2009.52\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A non-contact capacitive biopotential electrode with a common-mode noise suppression circuit is presented. The sensor network utilizes a single conductive sheet to establish a common body wide reference line, eliminating the need for an explicit signal ground connection. Each electrode senses the local biopotential with a differential gain of 46dB over a 1-100Hz bandwidth. Signals are digitized directly on board with a 16-bit ADC. The coin sized electrode consumes 285uA from a single 3.3V supply, and interfaces with a serial data bus for daisy-chain integration in body area sensor networks.\",\"PeriodicalId\":269861,\"journal\":{\"name\":\"2009 Sixth International Workshop on Wearable and Implantable Body Sensor Networks\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-06-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"109\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 Sixth International Workshop on Wearable and Implantable Body Sensor Networks\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BSN.2009.52\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 Sixth International Workshop on Wearable and Implantable Body Sensor Networks","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BSN.2009.52","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Non-contact Low Power EEG/ECG Electrode for High Density Wearable Biopotential Sensor Networks
A non-contact capacitive biopotential electrode with a common-mode noise suppression circuit is presented. The sensor network utilizes a single conductive sheet to establish a common body wide reference line, eliminating the need for an explicit signal ground connection. Each electrode senses the local biopotential with a differential gain of 46dB over a 1-100Hz bandwidth. Signals are digitized directly on board with a 16-bit ADC. The coin sized electrode consumes 285uA from a single 3.3V supply, and interfaces with a serial data bus for daisy-chain integration in body area sensor networks.