评估利用能源储存的区域减排潜力

A. Pimm, E. Barbour, T. Cockerill, Jan Palczewski
{"title":"评估利用能源储存的区域减排潜力","authors":"A. Pimm, E. Barbour, T. Cockerill, Jan Palczewski","doi":"10.1109/OSES.2019.8867357","DOIUrl":null,"url":null,"abstract":"Energy storage is an enabler of low carbon electricity generation, however several studies have shown that its use can cause a non-trivial increase in carbon emissions even if the storage has 100% round-trip efficiency. To understand the impact of storage operation and demand response on emissions, it is necessary to determine the marginal emissions factor (MEF) at the time the storage or demand response was operated. This paper presents statistical approaches to determining regional MEFs using data on regional electricity demand and generation by fuel type, with a simple power flow model used to determine consumption emissions by region. The technique is applied to the electricity system in Great Britain in 2018. It is found that the impact of storage varies widely by location and operating mode, with the greatest emissions reductions achieved when storage is used to reduce wind curtailment in areas which consume high levels of fossil fuel generation, and the greatest emissions increases occurring where storage is used for wind balancing in areas where wind is not curtailed. The difference between the highest emissions reduction and highest emissions increase is found to be significant, at 785 gCO2 per kWh that passes through storage.","PeriodicalId":416860,"journal":{"name":"2019 Offshore Energy and Storage Summit (OSES)","volume":"200 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-10-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Evaluating the regional potential for emissions reduction using energy storage\",\"authors\":\"A. Pimm, E. Barbour, T. Cockerill, Jan Palczewski\",\"doi\":\"10.1109/OSES.2019.8867357\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Energy storage is an enabler of low carbon electricity generation, however several studies have shown that its use can cause a non-trivial increase in carbon emissions even if the storage has 100% round-trip efficiency. To understand the impact of storage operation and demand response on emissions, it is necessary to determine the marginal emissions factor (MEF) at the time the storage or demand response was operated. This paper presents statistical approaches to determining regional MEFs using data on regional electricity demand and generation by fuel type, with a simple power flow model used to determine consumption emissions by region. The technique is applied to the electricity system in Great Britain in 2018. It is found that the impact of storage varies widely by location and operating mode, with the greatest emissions reductions achieved when storage is used to reduce wind curtailment in areas which consume high levels of fossil fuel generation, and the greatest emissions increases occurring where storage is used for wind balancing in areas where wind is not curtailed. The difference between the highest emissions reduction and highest emissions increase is found to be significant, at 785 gCO2 per kWh that passes through storage.\",\"PeriodicalId\":416860,\"journal\":{\"name\":\"2019 Offshore Energy and Storage Summit (OSES)\",\"volume\":\"200 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-10-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 Offshore Energy and Storage Summit (OSES)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/OSES.2019.8867357\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 Offshore Energy and Storage Summit (OSES)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/OSES.2019.8867357","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

储能是低碳发电的推动者,然而一些研究表明,即使储能具有100%的往返效率,它的使用也会导致碳排放的显著增加。为了了解储能运行和需求响应对排放的影响,有必要确定储能或需求响应运行时的边际排放因子(MEF)。本文介绍了利用按燃料类型划分的区域电力需求和发电量数据来确定区域mef的统计方法,并使用一个简单的潮流模型来确定按区域划分的消费排放。该技术将于2018年应用于英国的电力系统。研究发现,储能的影响因地点和运行模式的不同而有很大差异,在消耗大量化石燃料发电的地区,储能用于减少弃风时,减排效果最大,而在不弃风的地区,储能用于风平衡时,排放增幅最大。最高排放量减少和最高排放量增加之间的差异是显著的,每千瓦时通过储存的二氧化碳为785克。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Evaluating the regional potential for emissions reduction using energy storage
Energy storage is an enabler of low carbon electricity generation, however several studies have shown that its use can cause a non-trivial increase in carbon emissions even if the storage has 100% round-trip efficiency. To understand the impact of storage operation and demand response on emissions, it is necessary to determine the marginal emissions factor (MEF) at the time the storage or demand response was operated. This paper presents statistical approaches to determining regional MEFs using data on regional electricity demand and generation by fuel type, with a simple power flow model used to determine consumption emissions by region. The technique is applied to the electricity system in Great Britain in 2018. It is found that the impact of storage varies widely by location and operating mode, with the greatest emissions reductions achieved when storage is used to reduce wind curtailment in areas which consume high levels of fossil fuel generation, and the greatest emissions increases occurring where storage is used for wind balancing in areas where wind is not curtailed. The difference between the highest emissions reduction and highest emissions increase is found to be significant, at 785 gCO2 per kWh that passes through storage.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Evaluating the regional potential for emissions reduction using energy storage A comparative study of the Adiabatic Compressed Air Energy Storage (A-CAES) and Pumped Thermal Energy Storage (PTES) systems Modelling the effects of low-cost large-scale energy storage in the UK electricity network Present Status and Challenges for the Interaction between Offshore Wind Farms and Maritime Navigation in the Taiwan Strait Modeling of Multiterminal HVDC Offshore Grids with Renewable Energy and Storage Integration by Opensource Tools
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1