肾MR灌注加权成像中b-SSFP序列的数值模拟

A. Klepaczko, P. Skulimowski, M. Strzelecki, L. Stefanczyk, E. Eikefjord, J. Rørvik, A. Lundervold
{"title":"肾MR灌注加权成像中b-SSFP序列的数值模拟","authors":"A. Klepaczko, P. Skulimowski, M. Strzelecki, L. Stefanczyk, E. Eikefjord, J. Rørvik, A. Lundervold","doi":"10.23919/SPA.2018.8563339","DOIUrl":null,"url":null,"abstract":"Magnetic resonance (MR) simulation is one of the possible approaches to test and develop new imaging protocols. It can assist in fast, on-demand verification of various hypotheses concerning the impact of different physical and/or technical factors on image appearance. In this paper, we perform numerical simulation of dynamic contrast-enhanced MR imaging. In particular, we present the implementation of the so-called balanced steady state free precession sequence and show its application in the synthesis of DCE-MR images mimicking perfusion-weighted examinations of the kidney. To this end, we designed a simplified digital phantom of renal parenchyma comprising of kidney cortex and medulla. The phantom was constructed based on manual segmentation of a real high-resolution CT image of the abdomen. The contrast agent kinetics was incorporated into the model by assigning time-varying $T_{1}$ relaxation time to the kidney tissue segments. The relevant T1 time courses were determined based on analysis of real DCE-MR studies. Eventually, the practical aspects of the designed simulator are illustrated in an example application, where selected image-derived perfusion characteristics are referred to physiological parameters of the kidney.","PeriodicalId":265587,"journal":{"name":"2018 Signal Processing: Algorithms, Architectures, Arrangements, and Applications (SPA)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Numerical simulation of the b-SSFP sequence in MR perfusion-weighted imaging of the kidney\",\"authors\":\"A. Klepaczko, P. Skulimowski, M. Strzelecki, L. Stefanczyk, E. Eikefjord, J. Rørvik, A. Lundervold\",\"doi\":\"10.23919/SPA.2018.8563339\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Magnetic resonance (MR) simulation is one of the possible approaches to test and develop new imaging protocols. It can assist in fast, on-demand verification of various hypotheses concerning the impact of different physical and/or technical factors on image appearance. In this paper, we perform numerical simulation of dynamic contrast-enhanced MR imaging. In particular, we present the implementation of the so-called balanced steady state free precession sequence and show its application in the synthesis of DCE-MR images mimicking perfusion-weighted examinations of the kidney. To this end, we designed a simplified digital phantom of renal parenchyma comprising of kidney cortex and medulla. The phantom was constructed based on manual segmentation of a real high-resolution CT image of the abdomen. The contrast agent kinetics was incorporated into the model by assigning time-varying $T_{1}$ relaxation time to the kidney tissue segments. The relevant T1 time courses were determined based on analysis of real DCE-MR studies. Eventually, the practical aspects of the designed simulator are illustrated in an example application, where selected image-derived perfusion characteristics are referred to physiological parameters of the kidney.\",\"PeriodicalId\":265587,\"journal\":{\"name\":\"2018 Signal Processing: Algorithms, Architectures, Arrangements, and Applications (SPA)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 Signal Processing: Algorithms, Architectures, Arrangements, and Applications (SPA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.23919/SPA.2018.8563339\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 Signal Processing: Algorithms, Architectures, Arrangements, and Applications (SPA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/SPA.2018.8563339","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

磁共振(MR)模拟是测试和开发新的成像方案的可能方法之一。它可以帮助快速,按需验证关于不同物理和/或技术因素对图像外观的影响的各种假设。在本文中,我们进行了动态对比增强磁共振成像的数值模拟。特别是,我们提出了所谓的平衡稳态自由进动序列的实现,并展示了其在模拟肾脏灌注加权检查的DCE-MR图像合成中的应用。为此,我们设计了一个由肾皮质和肾髓质组成的简化的肾实质数字幻影。基于对真实的高分辨率腹部CT图像的人工分割构建幻像。通过给肾脏组织段分配随时间变化的$T_{1}$松弛时间,将造影剂动力学纳入模型。根据实际DCE-MR研究的分析确定相关的T1时间过程。最后,在一个示例应用中说明了所设计的模拟器的实际方面,其中选择的图像衍生灌注特性参考了肾脏的生理参数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Numerical simulation of the b-SSFP sequence in MR perfusion-weighted imaging of the kidney
Magnetic resonance (MR) simulation is one of the possible approaches to test and develop new imaging protocols. It can assist in fast, on-demand verification of various hypotheses concerning the impact of different physical and/or technical factors on image appearance. In this paper, we perform numerical simulation of dynamic contrast-enhanced MR imaging. In particular, we present the implementation of the so-called balanced steady state free precession sequence and show its application in the synthesis of DCE-MR images mimicking perfusion-weighted examinations of the kidney. To this end, we designed a simplified digital phantom of renal parenchyma comprising of kidney cortex and medulla. The phantom was constructed based on manual segmentation of a real high-resolution CT image of the abdomen. The contrast agent kinetics was incorporated into the model by assigning time-varying $T_{1}$ relaxation time to the kidney tissue segments. The relevant T1 time courses were determined based on analysis of real DCE-MR studies. Eventually, the practical aspects of the designed simulator are illustrated in an example application, where selected image-derived perfusion characteristics are referred to physiological parameters of the kidney.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Vehicle detector training with labels derived from background subtraction algorithms in video surveillance Automatic 3D segmentation of MRI data for detection of head and neck cancerous lymph nodes Centerline-Radius Polygonal-Mesh Modeling of Bifurcated Blood Vessels in 3D Images using Conformal Mapping Active elimination of tonal components in acoustic signals An adaptive transmission algorithm for an inertial motion capture system in the aspect of energy saving
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1