中压输电线路主缆存在时继电保护操作与电气安全的探讨

M. Mehmed-Hamza, Plamen Stanchev, M. Yordanova
{"title":"中压输电线路主缆存在时继电保护操作与电气安全的探讨","authors":"M. Mehmed-Hamza, Plamen Stanchev, M. Yordanova","doi":"10.1109/BULEF.2018.8646931","DOIUrl":null,"url":null,"abstract":"In the medium voltage power lines there is a tendency of enlargement of the cable part. This in turn leads to increase of the earth-fault currents. The practical experience has shown that it is important to consider that enlargement when designing the grounding of the neutral of mixed or cable power lines for medium voltage (normally through an active resistance). The value of the earth-fault current Ig has to be limited in view of limitation the level of the overvoltages and the damages of the equipment, the requirements for the selectiveness and the sensitiveness of the relay protection, the permissible touch Ut and step Us voltages at the earth-fault place. The purpose of the paper is to investigate the operation of the relay protection and the electrical safety in the conditions of enlargement of the share of the cable part in the medium voltage power lines. The values of the possible touch and step voltages have been compared with the maximum permitted values, calculated according to the international IEEE 80-2000 standard Guide for Safety in AC Substation Grounding.","PeriodicalId":416020,"journal":{"name":"2018 10th Electrical Engineering Faculty Conference (BulEF)","volume":"349 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Investigation of the Relay Protection Operation and the Electrical Safety at the Presence of Predominant Cable Part in Medium Voltage Power Lines\",\"authors\":\"M. Mehmed-Hamza, Plamen Stanchev, M. Yordanova\",\"doi\":\"10.1109/BULEF.2018.8646931\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In the medium voltage power lines there is a tendency of enlargement of the cable part. This in turn leads to increase of the earth-fault currents. The practical experience has shown that it is important to consider that enlargement when designing the grounding of the neutral of mixed or cable power lines for medium voltage (normally through an active resistance). The value of the earth-fault current Ig has to be limited in view of limitation the level of the overvoltages and the damages of the equipment, the requirements for the selectiveness and the sensitiveness of the relay protection, the permissible touch Ut and step Us voltages at the earth-fault place. The purpose of the paper is to investigate the operation of the relay protection and the electrical safety in the conditions of enlargement of the share of the cable part in the medium voltage power lines. The values of the possible touch and step voltages have been compared with the maximum permitted values, calculated according to the international IEEE 80-2000 standard Guide for Safety in AC Substation Grounding.\",\"PeriodicalId\":416020,\"journal\":{\"name\":\"2018 10th Electrical Engineering Faculty Conference (BulEF)\",\"volume\":\"349 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 10th Electrical Engineering Faculty Conference (BulEF)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BULEF.2018.8646931\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 10th Electrical Engineering Faculty Conference (BulEF)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BULEF.2018.8646931","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

在中压输电线中,电缆部分有增大的趋势。这反过来又导致地断层电流的增加。实践经验表明,在设计中压混合或电缆电力线的中性点接地(通常通过有源电阻)时,考虑该放大是很重要的。考虑到过电压的限制程度和设备的损坏程度,继电保护的选择性和灵敏度要求,接地故障地点允许的触点电压和步进电压,对接地故障电流Ig的取值必须加以限制。本文的目的是研究在中压输电线路中电缆部分比重增大的情况下继电保护的运行情况和电气安全问题。将可能的接触电压和步进电压的值与根据国际IEEE 80-2000标准《交流变电站接地安全指南》计算的最大允许值进行了比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Investigation of the Relay Protection Operation and the Electrical Safety at the Presence of Predominant Cable Part in Medium Voltage Power Lines
In the medium voltage power lines there is a tendency of enlargement of the cable part. This in turn leads to increase of the earth-fault currents. The practical experience has shown that it is important to consider that enlargement when designing the grounding of the neutral of mixed or cable power lines for medium voltage (normally through an active resistance). The value of the earth-fault current Ig has to be limited in view of limitation the level of the overvoltages and the damages of the equipment, the requirements for the selectiveness and the sensitiveness of the relay protection, the permissible touch Ut and step Us voltages at the earth-fault place. The purpose of the paper is to investigate the operation of the relay protection and the electrical safety in the conditions of enlargement of the share of the cable part in the medium voltage power lines. The values of the possible touch and step voltages have been compared with the maximum permitted values, calculated according to the international IEEE 80-2000 standard Guide for Safety in AC Substation Grounding.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Short-term power output forecasting of the photovoltaics in Bulgaria Coordination of the relay protection settings against phase to phase faults in electric power lines 20 kV A possibility for improving voltage quality intended for sensitive consumers Simulation of probabilistic models Investigation of the Relay Protection Operation and the Electrical Safety at the Presence of Predominant Cable Part in Medium Voltage Power Lines
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1