使用毫米波雷达进行连续血压测量

Ryota Kawasaki, A. Kajiwara
{"title":"使用毫米波雷达进行连续血压测量","authors":"Ryota Kawasaki, A. Kajiwara","doi":"10.1109/RWS53089.2022.9719965","DOIUrl":null,"url":null,"abstract":"Blood pressure (BP) is one of the four main vital signs providing valuable medical information about the cardiovascular activity. In this paper, a new method for estimating systolic and diastolic BP in contact-free for comfort is proposed using a millimeter-wave (MMW) sensor. The MMW sensor is sensitive to small cardiac motion of 1mm or less included in chest surface motion because of the higher frequency and wider bandwidth available, thereby continuous systolic and diastolic BP per heartbeat would be able to be estimated from the time-domain features of unique cardiac motion waveform. Measurement was conducted with the MMW sensor system and the estimated systolic and diastolic BP are also compared with an intermittent BP monitor. As a result, the sensor system is found to estimate systolic and diastolic BP continuously.","PeriodicalId":113074,"journal":{"name":"2022 IEEE Radio and Wireless Symposium (RWS)","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-01-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Continuous blood pressure estimation using millimeter wave radar\",\"authors\":\"Ryota Kawasaki, A. Kajiwara\",\"doi\":\"10.1109/RWS53089.2022.9719965\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Blood pressure (BP) is one of the four main vital signs providing valuable medical information about the cardiovascular activity. In this paper, a new method for estimating systolic and diastolic BP in contact-free for comfort is proposed using a millimeter-wave (MMW) sensor. The MMW sensor is sensitive to small cardiac motion of 1mm or less included in chest surface motion because of the higher frequency and wider bandwidth available, thereby continuous systolic and diastolic BP per heartbeat would be able to be estimated from the time-domain features of unique cardiac motion waveform. Measurement was conducted with the MMW sensor system and the estimated systolic and diastolic BP are also compared with an intermittent BP monitor. As a result, the sensor system is found to estimate systolic and diastolic BP continuously.\",\"PeriodicalId\":113074,\"journal\":{\"name\":\"2022 IEEE Radio and Wireless Symposium (RWS)\",\"volume\":\"14 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-01-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 IEEE Radio and Wireless Symposium (RWS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/RWS53089.2022.9719965\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE Radio and Wireless Symposium (RWS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/RWS53089.2022.9719965","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

血压(BP)是四个主要生命体征之一,为心血管活动提供有价值的医学信息。本文提出了一种利用毫米波(MMW)传感器估算无接触舒张和收缩压的新方法。MMW传感器对包含在胸表运动中的小于1mm的小的心脏运动很敏感,因为MMW的频率更高,带宽更宽,因此可以根据独特的心脏运动波形的时域特征来估计每次心跳的连续收缩压和舒张压。用毫米波传感器系统进行测量,并与间歇血压监测仪比较估计的收缩压和舒张压。结果发现,传感器系统可以连续估计收缩压和舒张压。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Continuous blood pressure estimation using millimeter wave radar
Blood pressure (BP) is one of the four main vital signs providing valuable medical information about the cardiovascular activity. In this paper, a new method for estimating systolic and diastolic BP in contact-free for comfort is proposed using a millimeter-wave (MMW) sensor. The MMW sensor is sensitive to small cardiac motion of 1mm or less included in chest surface motion because of the higher frequency and wider bandwidth available, thereby continuous systolic and diastolic BP per heartbeat would be able to be estimated from the time-domain features of unique cardiac motion waveform. Measurement was conducted with the MMW sensor system and the estimated systolic and diastolic BP are also compared with an intermittent BP monitor. As a result, the sensor system is found to estimate systolic and diastolic BP continuously.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Comparison of Co-located and Distributed MIMO for Indoor Wireless Communication A Novel Miniaturized 100:1 Broadband Balun with a 4:1 Impedance Ratio A Full Ka-Band Compact Coax-to-Waveguide Transition With Shaped Internal Profile and Enhanced Fabrication Process Flexibility Fourier-Domain DAC-based Hybrid Transmitter for Wireless Communication in 28 GHz 5G bands Separation of Multiple Closely Spaced Sources Using Frequency Sweep Single-Channel Continuous Wave Doppler Radar
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1