H. Almabrouk, S. Kaziz, B. Mezghani, Fares Tounsi, Y. Bernard
{"title":"六轴单质量压电IMU的设计及诱导应力研究","authors":"H. Almabrouk, S. Kaziz, B. Mezghani, Fares Tounsi, Y. Bernard","doi":"10.1109/ICM.2018.8703989","DOIUrl":null,"url":null,"abstract":"This paper explores steps towards induced stress enhancement of a new improved design of a 6-axis single-mass piezoelectric motion sensor. The detailed numerical analysis was based on a previously developed and validated finite element model for the new design. The experimental data, reported in literature for a design with a similar geometry, has been used in the validation. Using the same dimensions' range, we detail the new improved design geometry. The analysis of the induced stress in response to x, y and z-accelerations shows that the new design offers better performances. In response to x-axis and z-axis accelerations, evaluated induced stress values are 2 and 2.5 orders of magnitude higher than those measured on the reported design, respectively.","PeriodicalId":305356,"journal":{"name":"2018 30th International Conference on Microelectronics (ICM)","volume":"19 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Design Presentation and Induced-Stress Study of a 6-axis Single-Mass Piezoelectric IMU\",\"authors\":\"H. Almabrouk, S. Kaziz, B. Mezghani, Fares Tounsi, Y. Bernard\",\"doi\":\"10.1109/ICM.2018.8703989\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper explores steps towards induced stress enhancement of a new improved design of a 6-axis single-mass piezoelectric motion sensor. The detailed numerical analysis was based on a previously developed and validated finite element model for the new design. The experimental data, reported in literature for a design with a similar geometry, has been used in the validation. Using the same dimensions' range, we detail the new improved design geometry. The analysis of the induced stress in response to x, y and z-accelerations shows that the new design offers better performances. In response to x-axis and z-axis accelerations, evaluated induced stress values are 2 and 2.5 orders of magnitude higher than those measured on the reported design, respectively.\",\"PeriodicalId\":305356,\"journal\":{\"name\":\"2018 30th International Conference on Microelectronics (ICM)\",\"volume\":\"19 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 30th International Conference on Microelectronics (ICM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICM.2018.8703989\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 30th International Conference on Microelectronics (ICM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICM.2018.8703989","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Design Presentation and Induced-Stress Study of a 6-axis Single-Mass Piezoelectric IMU
This paper explores steps towards induced stress enhancement of a new improved design of a 6-axis single-mass piezoelectric motion sensor. The detailed numerical analysis was based on a previously developed and validated finite element model for the new design. The experimental data, reported in literature for a design with a similar geometry, has been used in the validation. Using the same dimensions' range, we detail the new improved design geometry. The analysis of the induced stress in response to x, y and z-accelerations shows that the new design offers better performances. In response to x-axis and z-axis accelerations, evaluated induced stress values are 2 and 2.5 orders of magnitude higher than those measured on the reported design, respectively.