{"title":"高灵敏度磁催化气体传感器","authors":"Chih-Hsiung Shen, Shu-Jung Chen","doi":"10.1109/ICSENST.2013.6727687","DOIUrl":null,"url":null,"abstract":"Magnetic-catalyzed SnO2 with Fe3O4 of CMOS MEMS gas sensor is proposed and it's based on the magnetic-catalytic sensing mechanism to increase sensitivity. Beyond the conventional power dissipation of heating to maintain a certain working temperature, a new approach for gas sensor with magnetic-catalytic mechanism works at the ambient temperature without the consideration of active heating. The design and fabrication is realized by the standard 0.35μm CMOS process to fabricate a gas sensor with mesh stacked electrodes. For the preparation of magnetic sensing material, a prepared solution of sol-gel SnO2 is mixed at SnO2:Fe3O4 = 3:1, which was deposited onto mesh stacked electrodes. When the CO gas sensor is introduced, the sample is tested and verified inside a CO gas chamber with a magnetic field generator of solenoid coil. We also build a magnetic-catalytic gas reaction behavior description based on Gibbs free energy and the Eyring equation. A careful investigation of measurement results, at horizontal magnetic field, the sensitivity of proposed CO gas sensor reaches 1.73%/ppm under the 12 Gauss which shows widely applicable for an ultra-low power chemical microsensor with high sensitivity.","PeriodicalId":374655,"journal":{"name":"2013 Seventh International Conference on Sensing Technology (ICST)","volume":"124 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Highly sensitive magnetic-catalytic gas sensor\",\"authors\":\"Chih-Hsiung Shen, Shu-Jung Chen\",\"doi\":\"10.1109/ICSENST.2013.6727687\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Magnetic-catalyzed SnO2 with Fe3O4 of CMOS MEMS gas sensor is proposed and it's based on the magnetic-catalytic sensing mechanism to increase sensitivity. Beyond the conventional power dissipation of heating to maintain a certain working temperature, a new approach for gas sensor with magnetic-catalytic mechanism works at the ambient temperature without the consideration of active heating. The design and fabrication is realized by the standard 0.35μm CMOS process to fabricate a gas sensor with mesh stacked electrodes. For the preparation of magnetic sensing material, a prepared solution of sol-gel SnO2 is mixed at SnO2:Fe3O4 = 3:1, which was deposited onto mesh stacked electrodes. When the CO gas sensor is introduced, the sample is tested and verified inside a CO gas chamber with a magnetic field generator of solenoid coil. We also build a magnetic-catalytic gas reaction behavior description based on Gibbs free energy and the Eyring equation. A careful investigation of measurement results, at horizontal magnetic field, the sensitivity of proposed CO gas sensor reaches 1.73%/ppm under the 12 Gauss which shows widely applicable for an ultra-low power chemical microsensor with high sensitivity.\",\"PeriodicalId\":374655,\"journal\":{\"name\":\"2013 Seventh International Conference on Sensing Technology (ICST)\",\"volume\":\"124 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 Seventh International Conference on Sensing Technology (ICST)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSENST.2013.6727687\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 Seventh International Conference on Sensing Technology (ICST)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSENST.2013.6727687","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Magnetic-catalyzed SnO2 with Fe3O4 of CMOS MEMS gas sensor is proposed and it's based on the magnetic-catalytic sensing mechanism to increase sensitivity. Beyond the conventional power dissipation of heating to maintain a certain working temperature, a new approach for gas sensor with magnetic-catalytic mechanism works at the ambient temperature without the consideration of active heating. The design and fabrication is realized by the standard 0.35μm CMOS process to fabricate a gas sensor with mesh stacked electrodes. For the preparation of magnetic sensing material, a prepared solution of sol-gel SnO2 is mixed at SnO2:Fe3O4 = 3:1, which was deposited onto mesh stacked electrodes. When the CO gas sensor is introduced, the sample is tested and verified inside a CO gas chamber with a magnetic field generator of solenoid coil. We also build a magnetic-catalytic gas reaction behavior description based on Gibbs free energy and the Eyring equation. A careful investigation of measurement results, at horizontal magnetic field, the sensitivity of proposed CO gas sensor reaches 1.73%/ppm under the 12 Gauss which shows widely applicable for an ultra-low power chemical microsensor with high sensitivity.