以空气为传热流体的室温磁制冷机的改进

K. Nakamura, T. Kawanami, S. Hirano, M. Ikegawa, K. Fumoto
{"title":"以空气为传热流体的室温磁制冷机的改进","authors":"K. Nakamura, T. Kawanami, S. Hirano, M. Ikegawa, K. Fumoto","doi":"10.1109/THETA.2008.5167187","DOIUrl":null,"url":null,"abstract":"In order to elucidate the cooling characteristics and to improve the cooling performance of a room temperature magnetic refrigerator using air as a heat transfer fluid, experimental and analytical study concerned with the heat transfer characteristics of an active magnetic regenerator (AMR) are conducted. The basic components of the target system are a magnetic circuit, a test section, a fluid supplying system and an associated instrumentation. Spherical gadolinium particles are packed in the test section as a magnetic working substance. Temperature profiles under several operating conditions for the Air-AMR are measured and calculated. Also, those for the Water-AMR are investigated in order to compare with the Air-AMR. The results show that the AMR cycle is very effective for improvement of the cooling performance of a room-temperature magnetic refrigerator for both heat transfer fluids, because increase in the temperature span between the hot-end and the cold-end due to regeneration is realized. Furthermore, it is revealed that a high flow rate of air is necessary in order to improve the cooling performance of the Air-AMR refrigerator, compared with the case of the Water-AMR. It is also shown that thermophysical properties of the heat transfer fluid have a significant effect on the cooling characteristics of an AMR refrigerator.","PeriodicalId":414963,"journal":{"name":"2008 Second International Conference on Thermal Issues in Emerging Technologies","volume":"153 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":"{\"title\":\"Improvement of room temperature magnetic refrigerator using air as heat transfer fluid\",\"authors\":\"K. Nakamura, T. Kawanami, S. Hirano, M. Ikegawa, K. Fumoto\",\"doi\":\"10.1109/THETA.2008.5167187\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In order to elucidate the cooling characteristics and to improve the cooling performance of a room temperature magnetic refrigerator using air as a heat transfer fluid, experimental and analytical study concerned with the heat transfer characteristics of an active magnetic regenerator (AMR) are conducted. The basic components of the target system are a magnetic circuit, a test section, a fluid supplying system and an associated instrumentation. Spherical gadolinium particles are packed in the test section as a magnetic working substance. Temperature profiles under several operating conditions for the Air-AMR are measured and calculated. Also, those for the Water-AMR are investigated in order to compare with the Air-AMR. The results show that the AMR cycle is very effective for improvement of the cooling performance of a room-temperature magnetic refrigerator for both heat transfer fluids, because increase in the temperature span between the hot-end and the cold-end due to regeneration is realized. Furthermore, it is revealed that a high flow rate of air is necessary in order to improve the cooling performance of the Air-AMR refrigerator, compared with the case of the Water-AMR. It is also shown that thermophysical properties of the heat transfer fluid have a significant effect on the cooling characteristics of an AMR refrigerator.\",\"PeriodicalId\":414963,\"journal\":{\"name\":\"2008 Second International Conference on Thermal Issues in Emerging Technologies\",\"volume\":\"153 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"11\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 Second International Conference on Thermal Issues in Emerging Technologies\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/THETA.2008.5167187\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 Second International Conference on Thermal Issues in Emerging Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/THETA.2008.5167187","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

摘要

为了阐明以空气为传热介质的室温磁制冷机的制冷特性,提高制冷性能,对有源磁蓄热器的传热特性进行了实验和分析研究。目标系统的基本组成部分是磁路、测试部分、流体供应系统和相关仪器。球形钆颗粒作为磁性工质填充在试验段中。测量和计算了空气- amr在几种工况下的温度分布。此外,为了与Air-AMR进行比较,对Water-AMR进行了研究。结果表明,AMR循环对两种传热流体的制冷性能都有很好的改善作用,因为它实现了热端与冷端之间的温度跨度的增大。此外,与水- amr制冷机相比,空气- amr制冷机的冷却性能需要较大的空气流量。研究还表明,传热流体的热物理性质对AMR制冷机的制冷特性有显著影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Improvement of room temperature magnetic refrigerator using air as heat transfer fluid
In order to elucidate the cooling characteristics and to improve the cooling performance of a room temperature magnetic refrigerator using air as a heat transfer fluid, experimental and analytical study concerned with the heat transfer characteristics of an active magnetic regenerator (AMR) are conducted. The basic components of the target system are a magnetic circuit, a test section, a fluid supplying system and an associated instrumentation. Spherical gadolinium particles are packed in the test section as a magnetic working substance. Temperature profiles under several operating conditions for the Air-AMR are measured and calculated. Also, those for the Water-AMR are investigated in order to compare with the Air-AMR. The results show that the AMR cycle is very effective for improvement of the cooling performance of a room-temperature magnetic refrigerator for both heat transfer fluids, because increase in the temperature span between the hot-end and the cold-end due to regeneration is realized. Furthermore, it is revealed that a high flow rate of air is necessary in order to improve the cooling performance of the Air-AMR refrigerator, compared with the case of the Water-AMR. It is also shown that thermophysical properties of the heat transfer fluid have a significant effect on the cooling characteristics of an AMR refrigerator.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Microscale transprot in the thermal processing of new and emerging advanced materials Calculation of local heat transfer coefficient on axisymmetric geometries using different methods of fringe analysis EXperimental study of convective heat transfer and pressure loss of SiO2/water nanofluids Part 2: Imposed uniform heat flux - Energetic performance criterion Air flow regimes and IAQ modeling in air conditioned spaces Analytical simulation of rich hydrogen gas - Air Proton Exchange Membrane Fuel Cell system fueled by natural gas
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1