Christoph Schulze, W. Heinrich, J. Dunsmore, O. Bengtsson
{"title":"改进的矢量网络分析仪(VNA)系统的宽带矢量校正测量","authors":"Christoph Schulze, W. Heinrich, J. Dunsmore, O. Bengtsson","doi":"10.1109/arftg54656.2022.9896558","DOIUrl":null,"url":null,"abstract":"Vector corrected wideband measurements on a modified vector network analyzer system are presented using wideband modulated signals as stimulus. The modified system allows intermediate frequency (IF) bandWidths exceeding 5 GHz based on external wideband IF access, signal conditioning and digitalization. A combined RF and IF calibration has been developed that allows full-band calibration using CW excitation, while measurements are made with wideband modulated signals. Impedance measurements verify excellent accuracy at -59dB deviation for an electrically switched impedance which is only a few dB less than for narrowband measurements. Repeatability of calculated error terms for consecutive calibrations also show comparable performance as for narrow-band measurements. Wideband one-port impedance measurements at 12.5 GHz using a Schroeder signal with 500 MHz instantaneous bandwidth show less than -50dB deviation with coherent averaging even without correcting for mixer distortion.","PeriodicalId":375242,"journal":{"name":"2022 99th ARFTG Microwave Measurement Conference (ARFTG)","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-06-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Wideband Vector Corrected Measurements on a Modified Vector Network Analyzer (VNA) System\",\"authors\":\"Christoph Schulze, W. Heinrich, J. Dunsmore, O. Bengtsson\",\"doi\":\"10.1109/arftg54656.2022.9896558\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Vector corrected wideband measurements on a modified vector network analyzer system are presented using wideband modulated signals as stimulus. The modified system allows intermediate frequency (IF) bandWidths exceeding 5 GHz based on external wideband IF access, signal conditioning and digitalization. A combined RF and IF calibration has been developed that allows full-band calibration using CW excitation, while measurements are made with wideband modulated signals. Impedance measurements verify excellent accuracy at -59dB deviation for an electrically switched impedance which is only a few dB less than for narrowband measurements. Repeatability of calculated error terms for consecutive calibrations also show comparable performance as for narrow-band measurements. Wideband one-port impedance measurements at 12.5 GHz using a Schroeder signal with 500 MHz instantaneous bandwidth show less than -50dB deviation with coherent averaging even without correcting for mixer distortion.\",\"PeriodicalId\":375242,\"journal\":{\"name\":\"2022 99th ARFTG Microwave Measurement Conference (ARFTG)\",\"volume\":\"14 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-06-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 99th ARFTG Microwave Measurement Conference (ARFTG)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/arftg54656.2022.9896558\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 99th ARFTG Microwave Measurement Conference (ARFTG)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/arftg54656.2022.9896558","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Wideband Vector Corrected Measurements on a Modified Vector Network Analyzer (VNA) System
Vector corrected wideband measurements on a modified vector network analyzer system are presented using wideband modulated signals as stimulus. The modified system allows intermediate frequency (IF) bandWidths exceeding 5 GHz based on external wideband IF access, signal conditioning and digitalization. A combined RF and IF calibration has been developed that allows full-band calibration using CW excitation, while measurements are made with wideband modulated signals. Impedance measurements verify excellent accuracy at -59dB deviation for an electrically switched impedance which is only a few dB less than for narrowband measurements. Repeatability of calculated error terms for consecutive calibrations also show comparable performance as for narrow-band measurements. Wideband one-port impedance measurements at 12.5 GHz using a Schroeder signal with 500 MHz instantaneous bandwidth show less than -50dB deviation with coherent averaging even without correcting for mixer distortion.