{"title":"红外激光传感器新技术","authors":"T. Hanafy","doi":"10.1109/SIECPC.2011.5876977","DOIUrl":null,"url":null,"abstract":"The effect of IR laser pulses fluencies on the dielectric properties, X-ray diffraction, and Fourier Transform Infrared spectroscopy (FTIR), for Makrofol-DE 1–1 CC polycarbonate has been investigated in the temperature and frequency ranges of 300–375K and 10kHz–4MHz, respectively. IR laser fluencies are set from 0.47 to 7.07 J/cm2. Three relaxation processes namely, a, p, and y have been obtained. X-ray diffraction and FTIR spectroscopy have revealed that, the irradiation of Makrofol at the fluence range 0.94–7.07 J/cm2 causes crosslinking formation inside the sample. The attained results suggested strongly the applicability of Makrofol-DE in IR laser pulses sensors.","PeriodicalId":125634,"journal":{"name":"2011 Saudi International Electronics, Communications and Photonics Conference (SIECPC)","volume":"39 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-04-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"New techniques for IR laser sensors\",\"authors\":\"T. Hanafy\",\"doi\":\"10.1109/SIECPC.2011.5876977\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The effect of IR laser pulses fluencies on the dielectric properties, X-ray diffraction, and Fourier Transform Infrared spectroscopy (FTIR), for Makrofol-DE 1–1 CC polycarbonate has been investigated in the temperature and frequency ranges of 300–375K and 10kHz–4MHz, respectively. IR laser fluencies are set from 0.47 to 7.07 J/cm2. Three relaxation processes namely, a, p, and y have been obtained. X-ray diffraction and FTIR spectroscopy have revealed that, the irradiation of Makrofol at the fluence range 0.94–7.07 J/cm2 causes crosslinking formation inside the sample. The attained results suggested strongly the applicability of Makrofol-DE in IR laser pulses sensors.\",\"PeriodicalId\":125634,\"journal\":{\"name\":\"2011 Saudi International Electronics, Communications and Photonics Conference (SIECPC)\",\"volume\":\"39 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-04-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 Saudi International Electronics, Communications and Photonics Conference (SIECPC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SIECPC.2011.5876977\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 Saudi International Electronics, Communications and Photonics Conference (SIECPC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SIECPC.2011.5876977","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The effect of IR laser pulses fluencies on the dielectric properties, X-ray diffraction, and Fourier Transform Infrared spectroscopy (FTIR), for Makrofol-DE 1–1 CC polycarbonate has been investigated in the temperature and frequency ranges of 300–375K and 10kHz–4MHz, respectively. IR laser fluencies are set from 0.47 to 7.07 J/cm2. Three relaxation processes namely, a, p, and y have been obtained. X-ray diffraction and FTIR spectroscopy have revealed that, the irradiation of Makrofol at the fluence range 0.94–7.07 J/cm2 causes crosslinking formation inside the sample. The attained results suggested strongly the applicability of Makrofol-DE in IR laser pulses sensors.