托托卡比拉骨博兰戈区医院用真空管封闭红、黄血标本中钾电解质水平的比较

Sry Rahmatia Rauf, Muh. Rizman Naim, Haryanto
{"title":"托托卡比拉骨博兰戈区医院用真空管封闭红、黄血标本中钾电解质水平的比较","authors":"Sry Rahmatia Rauf, Muh. Rizman Naim, Haryanto","doi":"10.47918/jhts.v3i3.902","DOIUrl":null,"url":null,"abstract":"Blood electrolyte levels in the tube will decrease after 30 minutes of blood collection due to the hemolysis process at a rate of about 7 mg/dl per hour. This study aims to determine the comparison of potassium electrolyte levels in blood specimens using red and yellow vacuum tubes at Toto Kabila Hospital, Bone Bolango Regency.The method in this study used descriptive with a quantitative approach and the method used in this study was accidental sampling with a sample of 30 patients who were to be studied. \nThe method in this study used a quantitative approach with a descriptive type of research and the sampling technique used was accidental sampling with a sample of 30 patients who were to be studied. \nThe results of the comparison of potassium levels in vacuum tubes with red lids and vacuum tubes with yellow covers showed normal potassium levels in 24 samples or (80%) and abnormal potassium levels in 6 samples or (20%) with the results of the Mann -With a test on comparisons of potassium levels in tubes with red caps and yellow caps showing that .0.099 > 0.05 so that it can be concluded that there is nothing significant about potassium examination using vacuum tubes with red lids and vacuum tubes with yellow lids.","PeriodicalId":430397,"journal":{"name":"Journal of Health, Technology and Science (JHTS)","volume":"422 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-02-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"COMPARISON OF POTASSIUM ELECTROLYTE LEVELS IN BLOOD SPECI-MEN USING VACUUM TUBE CLOSE RED AND YELLOW AT TOTO KABILA HOSPITAL BONE BOLANGO DISTRICT\",\"authors\":\"Sry Rahmatia Rauf, Muh. Rizman Naim, Haryanto\",\"doi\":\"10.47918/jhts.v3i3.902\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Blood electrolyte levels in the tube will decrease after 30 minutes of blood collection due to the hemolysis process at a rate of about 7 mg/dl per hour. This study aims to determine the comparison of potassium electrolyte levels in blood specimens using red and yellow vacuum tubes at Toto Kabila Hospital, Bone Bolango Regency.The method in this study used descriptive with a quantitative approach and the method used in this study was accidental sampling with a sample of 30 patients who were to be studied. \\nThe method in this study used a quantitative approach with a descriptive type of research and the sampling technique used was accidental sampling with a sample of 30 patients who were to be studied. \\nThe results of the comparison of potassium levels in vacuum tubes with red lids and vacuum tubes with yellow covers showed normal potassium levels in 24 samples or (80%) and abnormal potassium levels in 6 samples or (20%) with the results of the Mann -With a test on comparisons of potassium levels in tubes with red caps and yellow caps showing that .0.099 > 0.05 so that it can be concluded that there is nothing significant about potassium examination using vacuum tubes with red lids and vacuum tubes with yellow lids.\",\"PeriodicalId\":430397,\"journal\":{\"name\":\"Journal of Health, Technology and Science (JHTS)\",\"volume\":\"422 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-02-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Health, Technology and Science (JHTS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.47918/jhts.v3i3.902\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Health, Technology and Science (JHTS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.47918/jhts.v3i3.902","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

由于溶血过程的速率约为每小时7毫克/分升,在采集血液30分钟后,管中的血液电解质水平会下降。本研究的目的是在Bone Bolango Regency的Toto Kabila医院使用红色和黄色真空管确定血液标本中钾电解质水平的比较。本研究采用描述性与定量相结合的方法,采用随机抽样的方法,选取30例待研究的患者作为样本。本研究采用定量方法,采用描述性研究,抽样技术为随机抽样,共选取30例待研究患者。钾水平的比较的结果在真空管红色盖子和真空管黄色封面显示,24个样品或正常钾水平(80%)和6样品或钾水平异常(20%)与曼——一个测试的结果比较钾水平管的红色帽和黄色帽子显示.0.099 > 0.05,可以得出结论,没有什么重大的钾考试使用真空管和红色的盖子和真空有黄色盖子的管子。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
COMPARISON OF POTASSIUM ELECTROLYTE LEVELS IN BLOOD SPECI-MEN USING VACUUM TUBE CLOSE RED AND YELLOW AT TOTO KABILA HOSPITAL BONE BOLANGO DISTRICT
Blood electrolyte levels in the tube will decrease after 30 minutes of blood collection due to the hemolysis process at a rate of about 7 mg/dl per hour. This study aims to determine the comparison of potassium electrolyte levels in blood specimens using red and yellow vacuum tubes at Toto Kabila Hospital, Bone Bolango Regency.The method in this study used descriptive with a quantitative approach and the method used in this study was accidental sampling with a sample of 30 patients who were to be studied. The method in this study used a quantitative approach with a descriptive type of research and the sampling technique used was accidental sampling with a sample of 30 patients who were to be studied. The results of the comparison of potassium levels in vacuum tubes with red lids and vacuum tubes with yellow covers showed normal potassium levels in 24 samples or (80%) and abnormal potassium levels in 6 samples or (20%) with the results of the Mann -With a test on comparisons of potassium levels in tubes with red caps and yellow caps showing that .0.099 > 0.05 so that it can be concluded that there is nothing significant about potassium examination using vacuum tubes with red lids and vacuum tubes with yellow lids.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
RELATIONSHIP OF PROVISION OF IRON (Fe) TABLETS TO HEMOGLOBIN (Hb) LEVELS IN ADOLESCENT WOMEN AT PUSKESMAS KABILA KAB. BONE BOLANGO DESCRIPTION OF EXAMINATION RESULTS FOR SYPHILIS / TP FAST IN PREGNANT WOMEN AT HEALTH CENTER, KOTA UTARA IDENTIFICATION OF THE FUNGI Candida albicans IN URINE ELDERLY WOMEN WITH INCONTINENCE IN GRIAJANATI ORIGINAL ORIGINAL, GORONTALO CITY DESCRIPTION OF TRIGLYCERIDE LEVELS IN OBESE PATIENTS IN THE WORKING AREA OF DR. M.M DUNDA LIMBOTO HOSPITAL Analysis of Coliform Bacterial Contamination in Tomato Sauce Snacks On Jalan Toto, Central Gorontalo City
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1