水-石蜡基假体在MRI质量保证测试中的初步研究

G. Lupi, A. Scorza, Maria Livia Rugiano, S. Sciuto, F. Bini
{"title":"水-石蜡基假体在MRI质量保证测试中的初步研究","authors":"G. Lupi, A. Scorza, Maria Livia Rugiano, S. Sciuto, F. Bini","doi":"10.1109/MeMeA.2015.7145218","DOIUrl":null,"url":null,"abstract":"Magnetic Resonance Imaging (MRI) scanners are widely used both for diagnostic purpose and in studies on material properties. As a consequence they play an important role in diagnosis of diseases and in materials investigations. MRI Quality assurance tests are mandatory to obtain and maintain optimal images during time, some institutional organizations have proposed requirements on MRI image quality even if there are no worldwide standardization procedures .The purpose of this study is to design a novel MRI phantom useful to evaluate basic image quality requirements: our phantom is designed, realized and tested in order to define specific image assurance protocols and tests. Moreover the developed device is low cost, reusable and can be filled with different MRI-compatible materials. In our application the phantom is filled with water and paraffin to compare contrast resolution and signal-to-noise ratio measurements for a same scanner. Tests have been performed on a 3T scanner with 7 different scansion settings. First experimental results are encouraging and confirm a previous theoretical investigation on the employed material characteristics. Therefore other tests and data are going to be collected for the future development and performance improvement of the device.","PeriodicalId":277757,"journal":{"name":"2015 IEEE International Symposium on Medical Measurements and Applications (MeMeA) Proceedings","volume":"111 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-05-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Preliminary study for a water-paraffin based phantom in MRI quality assurance test\",\"authors\":\"G. Lupi, A. Scorza, Maria Livia Rugiano, S. Sciuto, F. Bini\",\"doi\":\"10.1109/MeMeA.2015.7145218\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Magnetic Resonance Imaging (MRI) scanners are widely used both for diagnostic purpose and in studies on material properties. As a consequence they play an important role in diagnosis of diseases and in materials investigations. MRI Quality assurance tests are mandatory to obtain and maintain optimal images during time, some institutional organizations have proposed requirements on MRI image quality even if there are no worldwide standardization procedures .The purpose of this study is to design a novel MRI phantom useful to evaluate basic image quality requirements: our phantom is designed, realized and tested in order to define specific image assurance protocols and tests. Moreover the developed device is low cost, reusable and can be filled with different MRI-compatible materials. In our application the phantom is filled with water and paraffin to compare contrast resolution and signal-to-noise ratio measurements for a same scanner. Tests have been performed on a 3T scanner with 7 different scansion settings. First experimental results are encouraging and confirm a previous theoretical investigation on the employed material characteristics. Therefore other tests and data are going to be collected for the future development and performance improvement of the device.\",\"PeriodicalId\":277757,\"journal\":{\"name\":\"2015 IEEE International Symposium on Medical Measurements and Applications (MeMeA) Proceedings\",\"volume\":\"111 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-05-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE International Symposium on Medical Measurements and Applications (MeMeA) Proceedings\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MeMeA.2015.7145218\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE International Symposium on Medical Measurements and Applications (MeMeA) Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MeMeA.2015.7145218","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

磁共振成像(MRI)扫描仪广泛用于诊断目的和材料性质的研究。因此,它们在疾病诊断和材料调查中发挥着重要作用。MRI质量保证测试是在一段时间内获得和保持最佳图像的强制性要求,一些机构组织提出了对MRI图像质量的要求,即使没有世界性的标准化程序。本研究的目的是设计一种新的MRI模型,用于评估基本的图像质量要求:我们的模型是为了定义特定的图像保证协议和测试而设计、实现和测试的。此外,开发的设备成本低,可重复使用,可以填充不同的mri兼容材料。在我们的应用中,用水和石蜡填充模体来比较同一台扫描仪的对比度分辨率和信噪比测量值。在3T扫描仪上进行了7种不同扫描设置的测试。第一个实验结果令人鼓舞,并证实了先前对所用材料特性的理论研究。因此,将收集其他测试和数据,以供设备的未来开发和性能改进。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Preliminary study for a water-paraffin based phantom in MRI quality assurance test
Magnetic Resonance Imaging (MRI) scanners are widely used both for diagnostic purpose and in studies on material properties. As a consequence they play an important role in diagnosis of diseases and in materials investigations. MRI Quality assurance tests are mandatory to obtain and maintain optimal images during time, some institutional organizations have proposed requirements on MRI image quality even if there are no worldwide standardization procedures .The purpose of this study is to design a novel MRI phantom useful to evaluate basic image quality requirements: our phantom is designed, realized and tested in order to define specific image assurance protocols and tests. Moreover the developed device is low cost, reusable and can be filled with different MRI-compatible materials. In our application the phantom is filled with water and paraffin to compare contrast resolution and signal-to-noise ratio measurements for a same scanner. Tests have been performed on a 3T scanner with 7 different scansion settings. First experimental results are encouraging and confirm a previous theoretical investigation on the employed material characteristics. Therefore other tests and data are going to be collected for the future development and performance improvement of the device.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Needle detection by electro-localization for a needle EMG exam robotic simulator Evaluation of control modes for head motion-based control with motion sensors A novel automatically initialized level set approach based on region correlation for lumbar vertebrae CT image segmentation Smart environments using near-field communication and HTML5 New FEM 3D model for arm-cuff interface simulation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1