利用数字微流控生物芯片制备多重稀释样品

Sukanta Bhattacharjee, A. Banerjee, B. Bhattacharya
{"title":"利用数字微流控生物芯片制备多重稀释样品","authors":"Sukanta Bhattacharjee, A. Banerjee, B. Bhattacharya","doi":"10.1109/ISED.2012.73","DOIUrl":null,"url":null,"abstract":"Digital microfluidic (DMF) biochips offer a versatile platform for implementing several laboratory based biochemical protocols. These tiny chips can electrically control the dynamics of nanoliter volume of discrete fluid droplets on an electrode array with desired actuation patterns. One important step in biochemical sample preparation is dilution, where the objective is to prepare a fluid with a desired concentration factor. Bioassays implemented on DMF biochips may require several different concentration values of the same sample. In this paper, we propose a scheme in which a set of different target droplets (target concentration values ranged between 0% and 100%) can be produced using 0% concentration (buffer solution) and 100% concentration (sample/reagent), with an error bounded above by 1/2^(n+1) where concentration values are rounded-off by an n-bit binary fraction. Simulation results show that significant amount of savings in the number of mix-split steps and waste droplets can be achieved in comparison with the repeated use of existing single target based methods for generating multiple concentration factors.","PeriodicalId":276803,"journal":{"name":"2012 International Symposium on Electronic System Design (ISED)","volume":"27 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-12-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"14","resultStr":"{\"title\":\"Multiple Dilution Sample Preparation Using Digital Microfluidic Biochips\",\"authors\":\"Sukanta Bhattacharjee, A. Banerjee, B. Bhattacharya\",\"doi\":\"10.1109/ISED.2012.73\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Digital microfluidic (DMF) biochips offer a versatile platform for implementing several laboratory based biochemical protocols. These tiny chips can electrically control the dynamics of nanoliter volume of discrete fluid droplets on an electrode array with desired actuation patterns. One important step in biochemical sample preparation is dilution, where the objective is to prepare a fluid with a desired concentration factor. Bioassays implemented on DMF biochips may require several different concentration values of the same sample. In this paper, we propose a scheme in which a set of different target droplets (target concentration values ranged between 0% and 100%) can be produced using 0% concentration (buffer solution) and 100% concentration (sample/reagent), with an error bounded above by 1/2^(n+1) where concentration values are rounded-off by an n-bit binary fraction. Simulation results show that significant amount of savings in the number of mix-split steps and waste droplets can be achieved in comparison with the repeated use of existing single target based methods for generating multiple concentration factors.\",\"PeriodicalId\":276803,\"journal\":{\"name\":\"2012 International Symposium on Electronic System Design (ISED)\",\"volume\":\"27 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-12-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"14\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 International Symposium on Electronic System Design (ISED)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISED.2012.73\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 International Symposium on Electronic System Design (ISED)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISED.2012.73","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 14

摘要

数字微流控(DMF)生物芯片提供了一个通用的平台来实现几个基于实验室的生化协议。这些微小的芯片可以用电控制纳米升体积的离散液滴在电极阵列上的动力学,并具有所需的驱动模式。生化样品制备中的一个重要步骤是稀释,其目的是制备具有所需浓度因子的液体。在DMF生物芯片上实施的生物测定可能需要同一样品的几个不同的浓度值。在本文中,我们提出了一种方案,在该方案中,可以使用0%浓度(缓冲溶液)和100%浓度(样品/试剂)产生一组不同的目标液滴(目标浓度值范围在0%到100%之间),误差上限为1/2^(n+1),其中浓度值由n位二进制分数四舍五入。仿真结果表明,与重复使用现有的基于单一目标的多浓度因子生成方法相比,可以显著节省混合分裂步骤和浪费液滴的数量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Multiple Dilution Sample Preparation Using Digital Microfluidic Biochips
Digital microfluidic (DMF) biochips offer a versatile platform for implementing several laboratory based biochemical protocols. These tiny chips can electrically control the dynamics of nanoliter volume of discrete fluid droplets on an electrode array with desired actuation patterns. One important step in biochemical sample preparation is dilution, where the objective is to prepare a fluid with a desired concentration factor. Bioassays implemented on DMF biochips may require several different concentration values of the same sample. In this paper, we propose a scheme in which a set of different target droplets (target concentration values ranged between 0% and 100%) can be produced using 0% concentration (buffer solution) and 100% concentration (sample/reagent), with an error bounded above by 1/2^(n+1) where concentration values are rounded-off by an n-bit binary fraction. Simulation results show that significant amount of savings in the number of mix-split steps and waste droplets can be achieved in comparison with the repeated use of existing single target based methods for generating multiple concentration factors.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Multi-objective Low-Power CDFG Scheduling Using Fine-Grained DVS Architecture in Distributed Framework Improvement in Target Detectability Using Spread Spectrum Radar in Dispersive Channel Condition Systolic Variable Length Architecture for Discrete Fourier Transform in Long Term Evolution High Speed Generic Network Interface for Network on Chip Using Ping Pong Buffers Synthesis of Toffoli Networks: Status and Challenges
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1