不同室内温度下受控日光水平下的认知表现评估

G. Chinazzo, J. Wienold, M. Andersen
{"title":"不同室内温度下受控日光水平下的认知表现评估","authors":"G. Chinazzo, J. Wienold, M. Andersen","doi":"10.25039/X46.2019.PO004","DOIUrl":null,"url":null,"abstract":"This paper details the results of an experimental study investigating the influence of daylight illuminance levels and indoor temperatures on objective and subjective performance evaluations, investigated through paper-based tasks and questionnaires, respectively. Experiments were conducted in an office-like test room with controllable indoor temperature and easy-to-change glazing visible transmittance. A total of 84 participants took part in the experiment, performed only under clear sky conditions to avoid variations in illuminance. In a randomized order, participants were exposed to three daylight illuminance levels (on average 140, 610 and 1440 lux) at one of three temperature conditions: 19, 23 and 27°C. Results show that objective performance outcomes were not affected by daylight illuminance or temperature, nor by their interactions, but only by the order of the test presentation ( indicating a learning effect). Of the subjective responses, only perceived concentration was affected by daylight conditions, with a self-reported lower concentration under the low illuminance level.","PeriodicalId":121032,"journal":{"name":"PROCEEDINGS OF the 29th Quadrennial Session of the CIE","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-06-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"COGNITIVE PERFORMANCE EVALUATION UNDER CONTROLLED DAYLIGHT LEVELS AT DIFFERENT INDOOR TEMPERATURES\",\"authors\":\"G. Chinazzo, J. Wienold, M. Andersen\",\"doi\":\"10.25039/X46.2019.PO004\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper details the results of an experimental study investigating the influence of daylight illuminance levels and indoor temperatures on objective and subjective performance evaluations, investigated through paper-based tasks and questionnaires, respectively. Experiments were conducted in an office-like test room with controllable indoor temperature and easy-to-change glazing visible transmittance. A total of 84 participants took part in the experiment, performed only under clear sky conditions to avoid variations in illuminance. In a randomized order, participants were exposed to three daylight illuminance levels (on average 140, 610 and 1440 lux) at one of three temperature conditions: 19, 23 and 27°C. Results show that objective performance outcomes were not affected by daylight illuminance or temperature, nor by their interactions, but only by the order of the test presentation ( indicating a learning effect). Of the subjective responses, only perceived concentration was affected by daylight conditions, with a self-reported lower concentration under the low illuminance level.\",\"PeriodicalId\":121032,\"journal\":{\"name\":\"PROCEEDINGS OF the 29th Quadrennial Session of the CIE\",\"volume\":\"14 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-06-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"PROCEEDINGS OF the 29th Quadrennial Session of the CIE\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.25039/X46.2019.PO004\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"PROCEEDINGS OF the 29th Quadrennial Session of the CIE","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.25039/X46.2019.PO004","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

本文详细介绍了一项实验研究的结果,研究了日光照度水平和室内温度对客观和主观绩效评估的影响,分别通过纸质任务和问卷调查进行了调查。实验在一个类似办公室的试验室进行,室内温度可控,玻璃可见光透过率易于改变。共有84名参与者参加了这项实验,为了避免光照变化,实验只在晴朗的天空条件下进行。按照随机顺序,参与者在三种温度条件之一(19、23和27°C)下暴露于三种日光照度水平(平均140、610和1440勒克斯)。结果表明,客观表现结果不受日光照度或温度的影响,也不受它们的相互作用的影响,而只受测试呈现的顺序的影响(表明学习效应)。在主观反应中,只有感知浓度受到日光条件的影响,在低照度水平下,自我报告的浓度较低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
COGNITIVE PERFORMANCE EVALUATION UNDER CONTROLLED DAYLIGHT LEVELS AT DIFFERENT INDOOR TEMPERATURES
This paper details the results of an experimental study investigating the influence of daylight illuminance levels and indoor temperatures on objective and subjective performance evaluations, investigated through paper-based tasks and questionnaires, respectively. Experiments were conducted in an office-like test room with controllable indoor temperature and easy-to-change glazing visible transmittance. A total of 84 participants took part in the experiment, performed only under clear sky conditions to avoid variations in illuminance. In a randomized order, participants were exposed to three daylight illuminance levels (on average 140, 610 and 1440 lux) at one of three temperature conditions: 19, 23 and 27°C. Results show that objective performance outcomes were not affected by daylight illuminance or temperature, nor by their interactions, but only by the order of the test presentation ( indicating a learning effect). Of the subjective responses, only perceived concentration was affected by daylight conditions, with a self-reported lower concentration under the low illuminance level.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
COGNITIVE PERFORMANCE EVALUATION UNDER CONTROLLED DAYLIGHT LEVELS AT DIFFERENT INDOOR TEMPERATURES LIGHTING, QUALITY AND ARTIFICIAL INTELLIGENCE VISIBILITY IMPROVEMENT BY CCT TUNABLE LED HEADLAMP UNDER THE ADVERSE WEATHER CONDITIONS TESTING THE PREDICTIVE POWER OF VISUAL DISCOMFORT FROM GLARE METRICS IN THE NEAR-WINDOW AND NEAR-WALL ZONES OF THE DAYLIT CLASSROOM ENVIRONMENT AN INVESTIGATION OF A19 LED RETROFIT LAMPS IN THE TURKISH MARKET
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1