{"title":"研究了拉丝装置振动系统的谐振特性","authors":"Y. Novikov, V. Novikov","doi":"10.18698/0536-1044-2023-7-35-42","DOIUrl":null,"url":null,"abstract":"The paper presents review and numerical analytical calculation of the most common ultrasonic oscillatory systems. Resonance characteristics of the waveguides were measured at their analysis stage using the ANSYS CAE system. Resonant characteristics of the manufactured acoustic systems were measured on the experimental ultrasonic equipment. Distinctive features of the bimetallic copper-silver wire being a promising material for medical use, electronic components and measuring transducers are provided. Technique was developed for synthesizing and analyzing the waveguide systems for drawing the bimetallic copper-silver wire excluding the waveguide fitting operation in its manufacture. Study results are expanding scientific knowledge in the methodology of synthesis and analysis of the ultrasonic oscillatory systems of the drawing installations and could be used in design of the ultrasonic equipment.","PeriodicalId":198502,"journal":{"name":"Proceedings of Higher Educational Institutions. Маchine Building","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Studying resonance characteristics of the of drawing installation oscillatory systems\",\"authors\":\"Y. Novikov, V. Novikov\",\"doi\":\"10.18698/0536-1044-2023-7-35-42\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper presents review and numerical analytical calculation of the most common ultrasonic oscillatory systems. Resonance characteristics of the waveguides were measured at their analysis stage using the ANSYS CAE system. Resonant characteristics of the manufactured acoustic systems were measured on the experimental ultrasonic equipment. Distinctive features of the bimetallic copper-silver wire being a promising material for medical use, electronic components and measuring transducers are provided. Technique was developed for synthesizing and analyzing the waveguide systems for drawing the bimetallic copper-silver wire excluding the waveguide fitting operation in its manufacture. Study results are expanding scientific knowledge in the methodology of synthesis and analysis of the ultrasonic oscillatory systems of the drawing installations and could be used in design of the ultrasonic equipment.\",\"PeriodicalId\":198502,\"journal\":{\"name\":\"Proceedings of Higher Educational Institutions. Маchine Building\",\"volume\":\"6 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of Higher Educational Institutions. Маchine Building\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.18698/0536-1044-2023-7-35-42\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of Higher Educational Institutions. Маchine Building","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18698/0536-1044-2023-7-35-42","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Studying resonance characteristics of the of drawing installation oscillatory systems
The paper presents review and numerical analytical calculation of the most common ultrasonic oscillatory systems. Resonance characteristics of the waveguides were measured at their analysis stage using the ANSYS CAE system. Resonant characteristics of the manufactured acoustic systems were measured on the experimental ultrasonic equipment. Distinctive features of the bimetallic copper-silver wire being a promising material for medical use, electronic components and measuring transducers are provided. Technique was developed for synthesizing and analyzing the waveguide systems for drawing the bimetallic copper-silver wire excluding the waveguide fitting operation in its manufacture. Study results are expanding scientific knowledge in the methodology of synthesis and analysis of the ultrasonic oscillatory systems of the drawing installations and could be used in design of the ultrasonic equipment.