基于双低通滤波器的电网电压暂降补偿器电压暂降检测

Y. Sillapawicharn, Y. Kumsuwan
{"title":"基于双低通滤波器的电网电压暂降补偿器电压暂降检测","authors":"Y. Sillapawicharn, Y. Kumsuwan","doi":"10.1109/IEECON.2014.6925913","DOIUrl":null,"url":null,"abstract":"In this paper, dual low pass filter (DLPF)-based voltage sag detection for voltage sag compensator under distorted grid is proposed. The conventional synchronously rotating reference frame (CSRRF)-based voltage sag detection is the most famous voltage sag detection method in the past. However it has a huge disadvantage as a long delay of detection time. The detection time is moderately improved by the improved modified synchronously rotating reference frame (IMSRRF)-based voltage sag detection. This paper presents DLPF-based voltage sag detection which is providing the shortest detection time when comparing to other methods. The performance of proposed voltage sag detection is verified via computer simulations in various conditions.","PeriodicalId":306512,"journal":{"name":"2014 International Electrical Engineering Congress (iEECON)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2014-03-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Dual low pass filter-based voltage sag detection for voltage sag compensator under distorted grid voltages\",\"authors\":\"Y. Sillapawicharn, Y. Kumsuwan\",\"doi\":\"10.1109/IEECON.2014.6925913\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, dual low pass filter (DLPF)-based voltage sag detection for voltage sag compensator under distorted grid is proposed. The conventional synchronously rotating reference frame (CSRRF)-based voltage sag detection is the most famous voltage sag detection method in the past. However it has a huge disadvantage as a long delay of detection time. The detection time is moderately improved by the improved modified synchronously rotating reference frame (IMSRRF)-based voltage sag detection. This paper presents DLPF-based voltage sag detection which is providing the shortest detection time when comparing to other methods. The performance of proposed voltage sag detection is verified via computer simulations in various conditions.\",\"PeriodicalId\":306512,\"journal\":{\"name\":\"2014 International Electrical Engineering Congress (iEECON)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-03-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 International Electrical Engineering Congress (iEECON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IEECON.2014.6925913\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 International Electrical Engineering Congress (iEECON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IEECON.2014.6925913","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

提出了一种基于双低通滤波器的电压暂降检测方法,用于畸变电网下电压暂降补偿器的电压暂降检测。传统的基于同步旋转参照系(CSRRF)的电压暂降检测方法是目前最著名的电压暂降检测方法。但是它的缺点是检测时间的延迟太长。采用改进的修正同步旋转参照系(IMSRRF)电压暂降检测方法,提高了检测时间。本文提出了基于dlpf的电压暂降检测方法,与其他方法相比,该方法的检测时间最短。通过计算机仿真,验证了所提出的电压暂降检测方法的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Dual low pass filter-based voltage sag detection for voltage sag compensator under distorted grid voltages
In this paper, dual low pass filter (DLPF)-based voltage sag detection for voltage sag compensator under distorted grid is proposed. The conventional synchronously rotating reference frame (CSRRF)-based voltage sag detection is the most famous voltage sag detection method in the past. However it has a huge disadvantage as a long delay of detection time. The detection time is moderately improved by the improved modified synchronously rotating reference frame (IMSRRF)-based voltage sag detection. This paper presents DLPF-based voltage sag detection which is providing the shortest detection time when comparing to other methods. The performance of proposed voltage sag detection is verified via computer simulations in various conditions.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Design of a dielectric hole plasmonic nanoantenna with broad wavelength range Key Issues for integration of Renewable Energy and Distributed Generation into Thailand power grid Gain improvement of MSAs array by using curved woodpile EBG and U-shaped reflector Sugeno fuzzy logic control-based smart PV generators for frequency control in loop interconnected power systems Hybrid location awareness in cognitive radio system
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1