Marian Haescher, Denys J. C. Matthies, John Trimpop, B. Urban
{"title":"基于腕带加速度计的心率和呼吸频率地震心动图(SCG)测量方法与常用技术的比较研究","authors":"Marian Haescher, Denys J. C. Matthies, John Trimpop, B. Urban","doi":"10.1145/2790044.2790054","DOIUrl":null,"url":null,"abstract":"Since the human body is a living organism, it emits various life signs which can be traced with an action potential sensitive electromyography, but also with motion sensitive sensors such as typical inertial sensors. In this paper, we present a possibility to recognize the heart rate (HR), respiration rate (RR), and the muscular microvibrations (MV) by an accelerometer worn on the wrist. We compare our seismocardiography (SCG) / ballistocardiography (BCG) approach to commonly used measuring methods. In conclusion, our study confirmed that SCG/BCD with a wrist-worn accelerometer also provides accurate vital parameters. While the recognized RR deviated slightly from the ground truth (SD=16.61%), the detection of HR is non-significantly different (SD=1.63%) to the gold standard.","PeriodicalId":351171,"journal":{"name":"Proceedings of the 2nd international Workshop on Sensor-based Activity Recognition and Interaction","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-06-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"47","resultStr":"{\"title\":\"A study on measuring heart- and respiration-rate via wrist-worn accelerometer-based seismocardiography (SCG) in comparison to commonly applied technologies\",\"authors\":\"Marian Haescher, Denys J. C. Matthies, John Trimpop, B. Urban\",\"doi\":\"10.1145/2790044.2790054\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Since the human body is a living organism, it emits various life signs which can be traced with an action potential sensitive electromyography, but also with motion sensitive sensors such as typical inertial sensors. In this paper, we present a possibility to recognize the heart rate (HR), respiration rate (RR), and the muscular microvibrations (MV) by an accelerometer worn on the wrist. We compare our seismocardiography (SCG) / ballistocardiography (BCG) approach to commonly used measuring methods. In conclusion, our study confirmed that SCG/BCD with a wrist-worn accelerometer also provides accurate vital parameters. While the recognized RR deviated slightly from the ground truth (SD=16.61%), the detection of HR is non-significantly different (SD=1.63%) to the gold standard.\",\"PeriodicalId\":351171,\"journal\":{\"name\":\"Proceedings of the 2nd international Workshop on Sensor-based Activity Recognition and Interaction\",\"volume\":\"2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-06-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"47\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 2nd international Workshop on Sensor-based Activity Recognition and Interaction\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1145/2790044.2790054\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 2nd international Workshop on Sensor-based Activity Recognition and Interaction","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1145/2790044.2790054","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A study on measuring heart- and respiration-rate via wrist-worn accelerometer-based seismocardiography (SCG) in comparison to commonly applied technologies
Since the human body is a living organism, it emits various life signs which can be traced with an action potential sensitive electromyography, but also with motion sensitive sensors such as typical inertial sensors. In this paper, we present a possibility to recognize the heart rate (HR), respiration rate (RR), and the muscular microvibrations (MV) by an accelerometer worn on the wrist. We compare our seismocardiography (SCG) / ballistocardiography (BCG) approach to commonly used measuring methods. In conclusion, our study confirmed that SCG/BCD with a wrist-worn accelerometer also provides accurate vital parameters. While the recognized RR deviated slightly from the ground truth (SD=16.61%), the detection of HR is non-significantly different (SD=1.63%) to the gold standard.