{"title":"工作条件变化下有源钳位断续导模反激变换器的建模","authors":"C. Choi, C.K. Li, S. Kok","doi":"10.1109/PEDS.1999.792795","DOIUrl":null,"url":null,"abstract":"With the trend of miniaturization in electronic products, the power supply is one of the major components that needs to be reduced in size. Reduction in the size of power supplies can be achieved by a topology change from linear transformer type to switching mode. To reduce the size further, the switching frequency has to be increased. However, there are a number of limitations and problems associated with the increase of switching frequency. The active-clamp discontinuous mode flyback converter (ADCMFC) introduced in this paper is one of the solutions to increase the switching frequency. Besides, the paper also introduces an optimization method to obtain the transfer function of the ADCMFC under different operating conditions.","PeriodicalId":254764,"journal":{"name":"Proceedings of the IEEE 1999 International Conference on Power Electronics and Drive Systems. PEDS'99 (Cat. No.99TH8475)","volume":"42 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1999-07-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"39","resultStr":"{\"title\":\"Modeling of an active clamp discontinuous conduction mode flyback converter under variation of operating conditions\",\"authors\":\"C. Choi, C.K. Li, S. Kok\",\"doi\":\"10.1109/PEDS.1999.792795\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"With the trend of miniaturization in electronic products, the power supply is one of the major components that needs to be reduced in size. Reduction in the size of power supplies can be achieved by a topology change from linear transformer type to switching mode. To reduce the size further, the switching frequency has to be increased. However, there are a number of limitations and problems associated with the increase of switching frequency. The active-clamp discontinuous mode flyback converter (ADCMFC) introduced in this paper is one of the solutions to increase the switching frequency. Besides, the paper also introduces an optimization method to obtain the transfer function of the ADCMFC under different operating conditions.\",\"PeriodicalId\":254764,\"journal\":{\"name\":\"Proceedings of the IEEE 1999 International Conference on Power Electronics and Drive Systems. PEDS'99 (Cat. No.99TH8475)\",\"volume\":\"42 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-07-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"39\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the IEEE 1999 International Conference on Power Electronics and Drive Systems. PEDS'99 (Cat. No.99TH8475)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PEDS.1999.792795\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the IEEE 1999 International Conference on Power Electronics and Drive Systems. PEDS'99 (Cat. No.99TH8475)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEDS.1999.792795","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 39

摘要

随着电子产品小型化的趋势,电源是需要小型化的主要部件之一。减小电源的尺寸可以通过从线性变压器类型到开关模式的拓扑变化来实现。为了进一步减小尺寸,必须提高开关频率。然而,随着开关频率的增加,也存在一些限制和问题。本文提出的有源钳位断续模式反激变换器(ADCMFC)是提高开关频率的一种解决方案。此外,本文还介绍了一种优化ADCMFC在不同工况下传递函数的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Modeling of an active clamp discontinuous conduction mode flyback converter under variation of operating conditions
With the trend of miniaturization in electronic products, the power supply is one of the major components that needs to be reduced in size. Reduction in the size of power supplies can be achieved by a topology change from linear transformer type to switching mode. To reduce the size further, the switching frequency has to be increased. However, there are a number of limitations and problems associated with the increase of switching frequency. The active-clamp discontinuous mode flyback converter (ADCMFC) introduced in this paper is one of the solutions to increase the switching frequency. Besides, the paper also introduces an optimization method to obtain the transfer function of the ADCMFC under different operating conditions.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Dynamic analysis of electromechanical converters by means of the wavelet transform Analysis of the snubberless operation of the emitter turn-off thyristor (ETO) Modeling and control of automotive HID lamp ballast Voltage and current hybrid controlled PWM inverters using variable structure control Development of a fuel cell power conditioner system
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1