一组用于管道多重泄漏检测的非线性观测器

C. Verde, N. Visairo
{"title":"一组用于管道多重泄漏检测的非线性观测器","authors":"C. Verde, N. Visairo","doi":"10.1109/CCA.2001.973952","DOIUrl":null,"url":null,"abstract":"Extends a procedure for multiple leaks detection in a pipeline assuming a linear model to the nonlinear case. The residual generation problem is tackled in two parts. First, the nonlinear subsystem that is only decoupled from one leak and is coupled to the rest of the considered leaks is obtained. Since this subsystem for each leak satisfies a triangular form, the second part of the procedure involves the design of a set of nonlinear observers to generate the residuals which are sensitive to the leaks set. The procedure is validated taking real data of a water pilot pipeline 132mts long.","PeriodicalId":365390,"journal":{"name":"Proceedings of the 2001 IEEE International Conference on Control Applications (CCA'01) (Cat. No.01CH37204)","volume":"116 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-09-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":"{\"title\":\"Bank of nonlinear observers for the detection of multiple leaks in a pipeline\",\"authors\":\"C. Verde, N. Visairo\",\"doi\":\"10.1109/CCA.2001.973952\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Extends a procedure for multiple leaks detection in a pipeline assuming a linear model to the nonlinear case. The residual generation problem is tackled in two parts. First, the nonlinear subsystem that is only decoupled from one leak and is coupled to the rest of the considered leaks is obtained. Since this subsystem for each leak satisfies a triangular form, the second part of the procedure involves the design of a set of nonlinear observers to generate the residuals which are sensitive to the leaks set. The procedure is validated taking real data of a water pilot pipeline 132mts long.\",\"PeriodicalId\":365390,\"journal\":{\"name\":\"Proceedings of the 2001 IEEE International Conference on Control Applications (CCA'01) (Cat. No.01CH37204)\",\"volume\":\"116 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-09-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"13\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 2001 IEEE International Conference on Control Applications (CCA'01) (Cat. No.01CH37204)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CCA.2001.973952\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 2001 IEEE International Conference on Control Applications (CCA'01) (Cat. No.01CH37204)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CCA.2001.973952","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13

摘要

将假设线性模型的管道中多个泄漏检测过程扩展到非线性情况。残差生成问题分两部分解决。首先,获得了只与一个泄漏解耦并与其他考虑的泄漏耦合的非线性子系统。由于每个泄漏的子系统都满足三角形形式,因此该过程的第二部分涉及设计一组非线性观测器来生成对泄漏集敏感的残差。通过对132mts引水管道的实测数据验证了该方法的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Bank of nonlinear observers for the detection of multiple leaks in a pipeline
Extends a procedure for multiple leaks detection in a pipeline assuming a linear model to the nonlinear case. The residual generation problem is tackled in two parts. First, the nonlinear subsystem that is only decoupled from one leak and is coupled to the rest of the considered leaks is obtained. Since this subsystem for each leak satisfies a triangular form, the second part of the procedure involves the design of a set of nonlinear observers to generate the residuals which are sensitive to the leaks set. The procedure is validated taking real data of a water pilot pipeline 132mts long.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Pay-load estimation of a 2DOF flexible link robot using a delta-operator technique A mechatronics library for SIMULINK An adaptive sliding observer for sensorless control of synchronous motors Position and orientation estimation based on Kalman filtering of stereo images Quasi-unknown input observers for linear systems
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1