一种以管道压头为测量参数的流量测量新技术

S. Chakraborty, S. Bera, N. Mandal, Samik Marick, M. Chattopadhyay
{"title":"一种以管道压头为测量参数的流量测量新技术","authors":"S. Chakraborty, S. Bera, N. Mandal, Samik Marick, M. Chattopadhyay","doi":"10.1109/ICCECE.2017.8526234","DOIUrl":null,"url":null,"abstract":"An obstruction meter widely used to measure flow rate of a fluid through a pipe line works on the principle of Bernoulli's equation, where the pressure difference between two sides of the obstruction is taken as a measure of flow rate. Thus the pipe line may suffer from a loss of static pressure and maximum flowing capacity cannot be utilized. In the present paper a novel technique of flow measurement is proposed in order to avoid this difficulty of obstruction meter. In this technique, no obstruction is used in the pipe line and the decrease in pipe line pressure head due to flow is taken as measure of flow. The effect of static pressure head in the pipe line is cancelled out by using to specially design identical bourdon gauges where the movement of the free tip of the bourdon tubes due to pressure is sensed by identical inductive pick up coils. One of the special gauges senses the static pressure at the source under no flow condition and the other pressure gauge senses the pipe line pressure at a given flow rate of the fluid. The free arm of aU-shaped ferromagnetic wire attached with the free tip of each bourdon tube acts as a moveable core inside and inductive pick up coil fixed with the base plate of the bourdon tube. Thus the self inductance of each pick up coil changes the change of pressure in the bourdon tube. Hence the difference between the inductances the two coils measures the change of pipe line pressure due to flow only. In the present paper a modified op-amps based differential inductance measuring circuits is designed whose output varies with the variation of flow rate. This circuit acts as proposed flow transducer. Its principle of operation is describe in the paper the performance of a prototype unit tested experiment mentally is reported in the paper in terms of static characteristics. The characteristics are found to follow the mathematical relation derived in the paper with very good repeatability.","PeriodicalId":325599,"journal":{"name":"2017 International Conference on Computer, Electrical & Communication Engineering (ICCECE)","volume":"139 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"A Novel Technique of Flow Measurement Using Pipe Line Pressure Head as a Measuring Parameter\",\"authors\":\"S. Chakraborty, S. Bera, N. Mandal, Samik Marick, M. Chattopadhyay\",\"doi\":\"10.1109/ICCECE.2017.8526234\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An obstruction meter widely used to measure flow rate of a fluid through a pipe line works on the principle of Bernoulli's equation, where the pressure difference between two sides of the obstruction is taken as a measure of flow rate. Thus the pipe line may suffer from a loss of static pressure and maximum flowing capacity cannot be utilized. In the present paper a novel technique of flow measurement is proposed in order to avoid this difficulty of obstruction meter. In this technique, no obstruction is used in the pipe line and the decrease in pipe line pressure head due to flow is taken as measure of flow. The effect of static pressure head in the pipe line is cancelled out by using to specially design identical bourdon gauges where the movement of the free tip of the bourdon tubes due to pressure is sensed by identical inductive pick up coils. One of the special gauges senses the static pressure at the source under no flow condition and the other pressure gauge senses the pipe line pressure at a given flow rate of the fluid. The free arm of aU-shaped ferromagnetic wire attached with the free tip of each bourdon tube acts as a moveable core inside and inductive pick up coil fixed with the base plate of the bourdon tube. Thus the self inductance of each pick up coil changes the change of pressure in the bourdon tube. Hence the difference between the inductances the two coils measures the change of pipe line pressure due to flow only. In the present paper a modified op-amps based differential inductance measuring circuits is designed whose output varies with the variation of flow rate. This circuit acts as proposed flow transducer. Its principle of operation is describe in the paper the performance of a prototype unit tested experiment mentally is reported in the paper in terms of static characteristics. The characteristics are found to follow the mathematical relation derived in the paper with very good repeatability.\",\"PeriodicalId\":325599,\"journal\":{\"name\":\"2017 International Conference on Computer, Electrical & Communication Engineering (ICCECE)\",\"volume\":\"139 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 International Conference on Computer, Electrical & Communication Engineering (ICCECE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICCECE.2017.8526234\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 International Conference on Computer, Electrical & Communication Engineering (ICCECE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICCECE.2017.8526234","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

目前广泛用于测量流体通过管道流量的阻流计,其工作原理是伯努利方程,以阻流器两侧的压差作为流量的度量。因此,管道可能遭受静压损失,无法利用最大流量。本文提出了一种新的流量测量技术,以避免阻塞流量计的这一困难。该技术在管道中不设置障碍物,以流量引起的管道压头下降作为流量的度量。通过特别设计相同的波登表来抵消管道中静压头的影响,其中波登管的自由尖端由于压力而移动是由相同的感应拾取线圈来检测的。其中一个特殊压力表在无流量情况下检测源处的静压,另一个压力表在给定流体流速下检测管道压力。与每个波登管的自由尖端相连的au形铁磁线的自由臂在波登管内部作为可动铁芯和固定在波登管底板上的感应拾取线圈。因此,每个拾取线圈的自感改变了波登管内压力的变化。因此,两个线圈电感之间的差值只能测量由于流量引起的管道压力变化。本文设计了一种改进的基于运放的差分电感测量电路,其输出随流量的变化而变化。该电路作为提议的流量传感器。本文叙述了其工作原理,并从静态特性的角度报道了原型单元测试实验的性能。这些特性符合文中推导的数学关系,具有很好的重复性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A Novel Technique of Flow Measurement Using Pipe Line Pressure Head as a Measuring Parameter
An obstruction meter widely used to measure flow rate of a fluid through a pipe line works on the principle of Bernoulli's equation, where the pressure difference between two sides of the obstruction is taken as a measure of flow rate. Thus the pipe line may suffer from a loss of static pressure and maximum flowing capacity cannot be utilized. In the present paper a novel technique of flow measurement is proposed in order to avoid this difficulty of obstruction meter. In this technique, no obstruction is used in the pipe line and the decrease in pipe line pressure head due to flow is taken as measure of flow. The effect of static pressure head in the pipe line is cancelled out by using to specially design identical bourdon gauges where the movement of the free tip of the bourdon tubes due to pressure is sensed by identical inductive pick up coils. One of the special gauges senses the static pressure at the source under no flow condition and the other pressure gauge senses the pipe line pressure at a given flow rate of the fluid. The free arm of aU-shaped ferromagnetic wire attached with the free tip of each bourdon tube acts as a moveable core inside and inductive pick up coil fixed with the base plate of the bourdon tube. Thus the self inductance of each pick up coil changes the change of pressure in the bourdon tube. Hence the difference between the inductances the two coils measures the change of pipe line pressure due to flow only. In the present paper a modified op-amps based differential inductance measuring circuits is designed whose output varies with the variation of flow rate. This circuit acts as proposed flow transducer. Its principle of operation is describe in the paper the performance of a prototype unit tested experiment mentally is reported in the paper in terms of static characteristics. The characteristics are found to follow the mathematical relation derived in the paper with very good repeatability.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
SPP Based Compact Optical Power Splitter Using Two-Mode Interference Coupling SiC MOSFET Based VSC Used in HVDC Transmission with DC Fault Protection Scheme Performance Improvement of Tea Industry with Multi Objective Particle Swarm Optimisation A Comparative Study of Different Ensemble Learning Techniques Using Wisconsin Breast Cancer Dataset Cost Modelling, Sizing and Multi-Point Allocation of Solar Powered DG Using Multi-Objective Cuckoo Search Via Lévy Flights Considering Economic, Technical and Environmental Impacts Along with Voltage Stability
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1