{"title":"六端口测量的合理E-cross模型","authors":"V. Karlov, V. Borulko, M. Andreev","doi":"10.1109/MSMW.2013.6622118","DOIUrl":null,"url":null,"abstract":"Automated analyzers, based on six-port reflectometers (SPR), are widely used for measuring the parameters of the microwave devices. In the measurement transducer of SPR the matched multiport passive microwave connection is used for the complex composition of the reference wave generator and the wave reflected from the object. In this case the parameters of the measurement system are found by preliminary calibration using at least four standards of the complex reflection coefficient (RC).","PeriodicalId":104362,"journal":{"name":"2013 International Kharkov Symposium on Physics and Engineering of Microwaves, Millimeter and Submillimeter Waves","volume":"47 7","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-06-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Rational model of E-cross for six-port measurements\",\"authors\":\"V. Karlov, V. Borulko, M. Andreev\",\"doi\":\"10.1109/MSMW.2013.6622118\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Automated analyzers, based on six-port reflectometers (SPR), are widely used for measuring the parameters of the microwave devices. In the measurement transducer of SPR the matched multiport passive microwave connection is used for the complex composition of the reference wave generator and the wave reflected from the object. In this case the parameters of the measurement system are found by preliminary calibration using at least four standards of the complex reflection coefficient (RC).\",\"PeriodicalId\":104362,\"journal\":{\"name\":\"2013 International Kharkov Symposium on Physics and Engineering of Microwaves, Millimeter and Submillimeter Waves\",\"volume\":\"47 7\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-06-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 International Kharkov Symposium on Physics and Engineering of Microwaves, Millimeter and Submillimeter Waves\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MSMW.2013.6622118\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 International Kharkov Symposium on Physics and Engineering of Microwaves, Millimeter and Submillimeter Waves","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MSMW.2013.6622118","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Rational model of E-cross for six-port measurements
Automated analyzers, based on six-port reflectometers (SPR), are widely used for measuring the parameters of the microwave devices. In the measurement transducer of SPR the matched multiport passive microwave connection is used for the complex composition of the reference wave generator and the wave reflected from the object. In this case the parameters of the measurement system are found by preliminary calibration using at least four standards of the complex reflection coefficient (RC).