{"title":"听觉诱发反应阈值自动测定在线系统","authors":"R. Delgado, O. Ozdamar, E. Miskiel","doi":"10.1109/IEMBS.1988.95333","DOIUrl":null,"url":null,"abstract":"An online computer system has been developed to determine auditory-evoked-response thresholds for objective hearing testing of otherwise untestable patients. The system uses click-evoked auditory brainstem responses. Online threshold determination is accomplished by two modules: a response recognition unit which determines if a response is present and a threshold tracking unit which utilizes a modified PEST (parameter estimation by sequential testing) algorithm to determine the click intensity testing level. Thresholds obtained manually and automatically are compared in 161 tests from 62 ears. Results indicate that automatically obtained thresholds show a strong agreement with those obtained visually as determined by a panel of experts.<<ETX>>","PeriodicalId":227170,"journal":{"name":"Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1988-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"On-line system for automated auditory evoked response threshold determination\",\"authors\":\"R. Delgado, O. Ozdamar, E. Miskiel\",\"doi\":\"10.1109/IEMBS.1988.95333\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An online computer system has been developed to determine auditory-evoked-response thresholds for objective hearing testing of otherwise untestable patients. The system uses click-evoked auditory brainstem responses. Online threshold determination is accomplished by two modules: a response recognition unit which determines if a response is present and a threshold tracking unit which utilizes a modified PEST (parameter estimation by sequential testing) algorithm to determine the click intensity testing level. Thresholds obtained manually and automatically are compared in 161 tests from 62 ears. Results indicate that automatically obtained thresholds show a strong agreement with those obtained visually as determined by a panel of experts.<<ETX>>\",\"PeriodicalId\":227170,\"journal\":{\"name\":\"Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1988-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IEMBS.1988.95333\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IEMBS.1988.95333","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

一个在线计算机系统已经开发,以确定听觉诱发反应阈值客观听力测试,否则无法测试的病人。该系统使用点击引起的听觉脑干反应。在线阈值确定由两个模块完成:一个响应识别单元确定是否存在响应,一个阈值跟踪单元利用改进的PEST(通过顺序测试参数估计)算法确定点击强度测试水平。在62个耳朵的161个测试中,对手动和自动获得的阈值进行了比较。结果表明,自动获得的阈值与由专家小组确定的目测值具有很强的一致性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
On-line system for automated auditory evoked response threshold determination
An online computer system has been developed to determine auditory-evoked-response thresholds for objective hearing testing of otherwise untestable patients. The system uses click-evoked auditory brainstem responses. Online threshold determination is accomplished by two modules: a response recognition unit which determines if a response is present and a threshold tracking unit which utilizes a modified PEST (parameter estimation by sequential testing) algorithm to determine the click intensity testing level. Thresholds obtained manually and automatically are compared in 161 tests from 62 ears. Results indicate that automatically obtained thresholds show a strong agreement with those obtained visually as determined by a panel of experts.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Prognostic value of morphometry in papillary thyroid carcinoma An expert system approach to cystic fibrosis patient management Design and development of an electromagnetic cervical range of motion system EMG pattern classification of normal and anterior cruciate ligament injured subjects On-line system for automated auditory evoked response threshold determination
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1