{"title":"基于跟踪微分器的单相有源电力滤波器谐波电流检测方法的改进","authors":"Guoxian Shi, X. Zong, Xingong Cheng","doi":"10.1109/ICICIP.2015.7388194","DOIUrl":null,"url":null,"abstract":"Extended two-dimensional single-phase harmonic detection algorithm is an approach detecting the harmonic current in single-phase active power filter. However, it is not practical for some reason. In this paper, the algorithm was studied and then an improvement based on tracking differentiator (TD) was proposed to solve the problems existing in the extended two-dimensional single-phase harmonic detection algorithm, in which the magnitude of fundamental wave can be easily affected by high frequency noises of the input signal for the existence of derivation process. The new algorithm is capable of filtering perturbations and getting the derivative of input signal without noise amplification. It can make sure that a more accurate approximation of the real fundamental wave without distortion will be obtained, which can guarantee a lower harmonic content of the grid side current.","PeriodicalId":265426,"journal":{"name":"2015 Sixth International Conference on Intelligent Control and Information Processing (ICICIP)","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"An improved detecting approach of harmonic current in single-phase active power filter based on tracking differentiator\",\"authors\":\"Guoxian Shi, X. Zong, Xingong Cheng\",\"doi\":\"10.1109/ICICIP.2015.7388194\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Extended two-dimensional single-phase harmonic detection algorithm is an approach detecting the harmonic current in single-phase active power filter. However, it is not practical for some reason. In this paper, the algorithm was studied and then an improvement based on tracking differentiator (TD) was proposed to solve the problems existing in the extended two-dimensional single-phase harmonic detection algorithm, in which the magnitude of fundamental wave can be easily affected by high frequency noises of the input signal for the existence of derivation process. The new algorithm is capable of filtering perturbations and getting the derivative of input signal without noise amplification. It can make sure that a more accurate approximation of the real fundamental wave without distortion will be obtained, which can guarantee a lower harmonic content of the grid side current.\",\"PeriodicalId\":265426,\"journal\":{\"name\":\"2015 Sixth International Conference on Intelligent Control and Information Processing (ICICIP)\",\"volume\":\"7 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 Sixth International Conference on Intelligent Control and Information Processing (ICICIP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICICIP.2015.7388194\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 Sixth International Conference on Intelligent Control and Information Processing (ICICIP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICICIP.2015.7388194","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
An improved detecting approach of harmonic current in single-phase active power filter based on tracking differentiator
Extended two-dimensional single-phase harmonic detection algorithm is an approach detecting the harmonic current in single-phase active power filter. However, it is not practical for some reason. In this paper, the algorithm was studied and then an improvement based on tracking differentiator (TD) was proposed to solve the problems existing in the extended two-dimensional single-phase harmonic detection algorithm, in which the magnitude of fundamental wave can be easily affected by high frequency noises of the input signal for the existence of derivation process. The new algorithm is capable of filtering perturbations and getting the derivative of input signal without noise amplification. It can make sure that a more accurate approximation of the real fundamental wave without distortion will be obtained, which can guarantee a lower harmonic content of the grid side current.